The accuracy of quantitative parameters in Tc-99m-MAG3 dynamic renography: a national audit based on virtual image data
Show others and affiliations
2016 (English)In: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 36, no 2, 146-154 p.Article in journal (Refereed) PublishedText
Abstract [en]

Assessment of image analysis methods and computer software used in Tc-99m-MAG3 dynamic renography is important to ensure reliable study results and ultimately the best possible care for patients. In this work, we present a national multicentre study of the quantification accuracy in Tc-99m-MAG3 renography, utilizing virtual dynamic scintigraphic data obtained by Monte Carlo-simulated scintillation camera imaging of digital phantoms with time-varying activity distributions. Three digital phantom studies were distributed to the participating departments, and quantitative evaluation was performed with standard clinical software according to local routines. The differential renal function (DRF) and time to maximum renal activity (T-max) were reported by 21 of the 28 Swedish departments performing Tc-99m-MAG3 studies as of 2012. The reported DRF estimates showed a significantly lower precision for the phantom with impaired renal uptake than for the phantom with normal uptake. The T-max estimates showed a similar trend, but the difference was only significant for the right kidney. There was a significant bias in the measured DRF for all phantoms caused by different positions of the left and right kidney in the anterior-posterior direction. In conclusion, this study shows that virtual scintigraphic studies are applicable for quality assurance and that there is a considerable uncertainty associated with standard quantitative parameters in dynamic Tc-99m-MAG3 renography, especially for patients with impaired renal function.

Place, publisher, year, edition, pages
2016. Vol. 36, no 2, 146-154 p.
Keyword [en]
Tc-99m-MAG3, differential renal function, digital phantoms, dynamic renography, Monte Carlo imaging simulations, quality assurance
National Category
Medical Image Processing
Identifiers
URN: urn:nbn:se:umu:diva-117804DOI: 10.1111/cpf.12208ISI: 000370199700010OAI: oai:DiVA.org:umu-117804DiVA: diva2:918420
Available from: 2016-04-11 Created: 2016-03-04 Last updated: 2016-04-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Riklund, Katrine
By organisation
Diagnostic Radiology
In the same journal
Clinical Physiology and Functional Imaging
Medical Image Processing

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 211 hits
ReferencesLink to record
Permanent link

Direct link