umu.sePublications
Change search
Refine search result
1 - 12 of 12
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Bain, G. I.
    et al.
    Australia .
    Polites, N.
    Australia .
    Higgs, B. G.
    Australia .
    Heptinstall, R. J.
    Unaffiliated .
    McGrath, Aleksandra
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    The functional range of motion of the finger joints2015In: Journal of Hand Surgery, European Volume, ISSN 1753-1934, E-ISSN 2043-6289, Vol. 40, no 4, p. 406-411Article in journal (Refereed)
    Abstract [en]

    The purpose of this study was to measure the functional range of motion of the finger joints needed to perform activities of daily living. Using the Sollerman hand grip function test, 20 activities were assessed in ten volunteers. The active and passive range of motion was measured with a computerized electric goniometer. The position of each finger joint was evaluated in the pre-grasp and grasp positions. The functional range of motion was defined as the range required to perform 90% of the activities, utilizing the pre-grasp and grasp measurements. The functional range of motion was 19 degrees-71 degrees, 23 degrees-87 degrees, and 10 degrees-64 degrees at the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints, respectively. This represents 48%, 59%, and 60% of the active motion of these joints, respectively. There was a significant difference in the functional range of motion between the joints of the fingers, with the ulnar digits having greater active and functional range. The functional range of motion is important for directing indications for surgery and rehabilitation, and assessing outcome of treatment.

  • 2. Bain, Gregory I
    et al.
    McGuire, Duncan T
    McGrath, Aleksandra M
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    A Simplified Lateral Hinge Approach to the Proximal Interphalangeal Joint2015In: Techniques in Hand & Upper Extremity Surgery, ISSN 1089-3393, E-ISSN 1531-6572, Vol. 19, no 3, p. 129-132Article in journal (Refereed)
    Abstract [en]

    Proximal interphalangeal joint replacement is an effective treatment for painful arthritis affecting the joint. However, the complication rate is relatively high, with many of these complications related to soft-tissue imbalance or instability. Volar, dorsal, and lateral approaches have all been described with varying results. We describe a new simplified lateral hinge approach that splits the collateral ligament to provide adequate exposure of the joint. Following insertion of the prosthesis the collateral ligament is simply repaired, side-to-side, which stabilizes the joint. As the central slip, opposite collateral ligament, flexor and extensor tendons have not been violated, early active mobilization without splinting is possible, and the risk of instability, swan-neck, and boutonniere deformity are reduced. The indications, contraindications, surgical technique, and rehabilitation protocol are described.

  • 3.
    Bourke, Gráinne
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB). Department of Plastic and Reconstructive Surgery, Leeds Teaching Hospitals Trust, Leeds, UK.
    McGrath, Aleksandra M.
    Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB). Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences. Department of Plastic and Reconstructive Surgery, Leeds Teaching Hospitals Trust, Leeds, UK.
    Novikov, Lev N.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB).
    Effects of early nerve repair on experimental brachial plexus injury in neonatal rats2018In: Journal of Hand Surgery, European Volume, ISSN 1753-1934, E-ISSN 2043-6289, Vol. 43, no 3, p. 275-281Article in journal (Refereed)
    Abstract [en]

    Obstetrical brachial plexus injury refers to injury observed at the time of delivery, which may lead to major functional impairment in the upper limb. In this study, the neuroprotective effect of early nerve repair following complete brachial plexus injury in neonatal rats was examined. Brachial plexus injury induced 90% loss of spinal motoneurons and 70% decrease in biceps muscle weight at 28 days after injury. Retrograde degeneration in spinal cord was associated with decreased density of dendritic branches and presynaptic boutons and increased density of astrocytes and macrophages/microglial cells. Early repair of the injured brachial plexus significantly delayed retrograde degeneration of spinal motoneurons and reduced the degree of macrophage/microglial reaction but had no effect on muscle atrophy. The results demonstrate that early nerve repair of neonatal brachial plexus injury could promote survival of injured motoneurons and attenuate neuroinflammation in spinal cord.

  • 4.
    Jonsson, Samuel
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Rebecca
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    McGrath, Aleksandra M
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Novikov, Lev N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Novikova, Liudmila N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Kingham, Paul J
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Effect of delayed peripheral nerve repair on nerve regeneration, Schwann cell function and target muscle recovery2013In: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 8, no 2, article id e56484Article in journal (Refereed)
    Abstract [en]

    Despite advances in surgical techniques for peripheral nerve repair, functional restitution remains incomplete. The timing of surgery is one factor influencing the extent of recovery but it is not yet clearly defined how long a delay may be tolerated before repair becomes futile. In this study, rats underwent sciatic nerve transection before immediate (0) or 1, 3, or 6 months delayed repair with a nerve graft. Regeneration of spinal motoneurons, 13 weeks after nerve repair, was assessed using retrograde labeling. Nerve tissue was also collected from the proximal and distal stumps and from the nerve graft, together with the medial gastrocnemius (MG) muscles. A dramatic decline in the number of regenerating motoneurons and myelinated axons in the distal nerve stump was observed in the 3- and 6-months delayed groups. After 3 months delay, the axonal number in the proximal stump increased 2-3 folds, accompanied by a smaller axonal area. RT-PCR of distal nerve segments revealed a decline in Schwann cells (SC) markers, most notably in the 3 and 6 month delayed repair samples. There was also a progressive increase in fibrosis and proteoglycan scar markers in the distal nerve with increased delayed repair time. The yield of SC isolated from the distal nerve segments progressively fell with increased delay in repair time but cultured SC from all groups proliferated at similar rates. MG muscle at 3- and 6-months delay repair showed a significant decline in weight (61% and 27% compared with contra-lateral side). Muscle fiber atrophy and changes to neuromuscular junctions were observed with increased delayed repair time suggestive of progressively impaired reinnervation. This study demonstrates that one of the main limiting factors for nerve regeneration after delayed repair is the distal stump. The critical time point after which the outcome of regeneration becomes too poor appears to be 3-months.

  • 5.
    McGrath, Aleksandra
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Development of biosynthetic conduits for peripheral nerve repair2012Doctoral thesis, comprehensive summary (Other academic)
    Abstract [en]

    Peripheral nerve injuries are often associated with significant loss of nervous tissue leading to poor restoration of function following repair of injured nerves. Although the injury gap could be bridged by autologous nerve graft, the limited access to donor material and additional morbidity such as loss of sensation and scarring have prompted a search for biosynthetic nerve transplants.

    The present thesis investigates the effects of a synthetic matrix BD™ PuraMatrix™ peptide (BD)hydrogel, alginate/fibronectin gel and fibrin glue combined with cultured rat Schwann cells or human bone marrow derived mesenchymal stem cells (MSC) on neuronal regeneration and muscle recovery after peripheral nerve injury in adult rats.

    In a sciatic nerve injury model, after 3 weeks postoperatively, the regenerating axons grew significantly longer distances within the conduits filled with BD hydrogel if compared with the alginate/fibronectin gel. The addition of rat Schwann cells to the BD hydrogel drastically increased regeneration distance with axons crossing the injury gap and entering into the distal nerve stump. However, at 16 weeks the number of regenerating spinal motoneurons was decreased to 49% and 31% in the BD hydrogel and alginate/fibronectin groups respectively. The recovery of the gastrocnemius muscle was also inferior in both experimental groups if compared with the nerve graft. The addition of the cultured Schwann cells did not further improve the regeneration of motoneurons and muscle recovery.

    The growth-promoting effects of the tubular conduits prepared from fibrin glue were also studied following repair of short and long peripheral nerve gaps. Retrograde neuronal labeling demonstrated that fibrin glue conduit promoted regeneration of 60% of injured sensory neurons and 52% of motoneurons when compared with the autologous nerve graft. The total number of myelinated axons in the distal nerve stump in the fibrin conduit group reached 86% of the nerve graft control and the weight of gastrocnemius and soleus muscles recovered to 82% and 89%, respectively. When a fibrin conduit was used to bridge a 20 mm sciatic nerve gap, the weight of gastrocnemius muscle reached only 43% of the nerve graft control. The morphology of the muscle showed a more atrophic appearance and the mean area and diameter of fast type fibres were significantly worse than those of the corresponding 10 mm gap group. In contrast, both gap sizes treated with nerve graft showed similar fiber size.

    The combination of fibrin conduit with human MSC and daily injections of cyclosporine A enhanced the distance of regeneration by four fold and the area occupied by regenerating axons by three fold at 3 weeks after nerve injury and repair. In addition, the treatment also significantly reduced the ED1 macrophage reaction. At 12 weeks after nerve injury the treatment with cyclosporine A alone or cyclosporine A combined with hMSC induced recovery of the muscle weight and the size of fast type fibres to the control levels of the nerve graft group.

    In summary, these results show that a BD hydrogel supplemented with rat Schwann cells can support the initial phase of neuronal regeneration across the conduit. The data also demonstrate an advantage of tubular fibrin conduits combined with human MSC to promote axonal regeneration and muscle recovery after peripheral nerve injury.

  • 6.
    McGrath, Aleksandra
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Brohlin, Maria
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Paul, Kingham
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Novikov, Lev
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Novikova, Liudmila
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Fibrin conduit supplemented with human mesenchymal stem cells supports regeneration after peripheral nerve injury   Manuscript (preprint) (Other academic)
    Abstract [en]

    To address the need for the development of bioengineered replacement of a nerve graft for treatment of peripheral nerve injuries a novel two component fibrin glue conduit was combined with human mesenchymal stem cells (hMSC) and immunosupressive treatment with cyclosporine. MSC possess the advantage of lower donor site morbidity and easier expandability in vitro compared with Schwann cells. The effects of hMSC on axonal regeneration in the conduit and reaction of activated macrophages was investigated using sciatic nerve injury model. The experiments were performed on 20 female Fischer rats (8-10 weeks old). A 10mm gap in the sciatic nerve was created and repaired either with fibrin glue conduit containing diluted fibrin matrix or fibrin glue conduit containing fibrin matrix with hMSC at concentration of 80x106 cells per ml. Cells were labeled with PKH26 prior to transplantation. The animals were allowed to survive for 3 weeks and some groups were treated with daily injections of cyclosporine. After 3 weeks the conduits were harvested and the distance of regeneration and area occupied by regenerating axons together with ED1 staining of activated macrophages was measured. hMSC survived in the conduit and enhanced axonal regeneration only when transplantation was combined with cyclosporine treatment. Moreover, cyclosporine significantly reduced the ED1 macrophage reaction.

  • 7.
    McGrath, Aleksandra M
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Brohlin, Maria
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Kingham, Paul J
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Novikov, Lev N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Novikova, Liudmila N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Fibrin conduit supplemented with human mesenchymal stem cells and immunosuppressive treatment enhances regeneration after peripheral nerve injury2012In: Neuroscience Letters, ISSN 0304-3940, E-ISSN 1872-7972, Vol. 516, no 2, p. 171-176Article in journal (Refereed)
    Abstract [en]

    To address the need for the development of bioengineered replacement of a nerve graft, a novel two component fibrin glue conduit was combined with human mesenchymal stem cells (MSC) and immunosupressive treatment with cyclosporine A. The effects of MSC on axonal regeneration in the conduit and reaction of activated macrophages were investigated using sciatic nerve injury model. A 10mm gap in the sciatic nerve of a rat was created and repaired either with fibrin glue conduit containing diluted fibrin matrix or fibrin glue conduit containing fibrin matrix with MSC at concentration of 80×10(6)cells/ml. Cells were labeled with PKH26 prior to transplantation. The animals received daily injections of cyclosporine A. After 3 weeks the distance of regeneration and area occupied by regenerating axons and ED1 positives macrophages was measured. MSC survived in the conduit and enhanced axonal regeneration only when transplantation was combined with cyclosporine A treatment. Moreover, addition of cyclosporine A to the conduits with transplanted MSC significantly reduced the ED1 macrophage reaction.

  • 8.
    McGrath, Aleksandra M.
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Norrlands Univ Hosp, Sect Hand & Plast Surg, Dept Surg & Perioperat Sci, Umea, Sweden.
    Brohlin, Maria
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Clinical Microbiology.
    Wiberg, Rebecca
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Norrlands Univ Hosp, Sect Hand & Plast Surg, Dept Surg & Perioperat Sci, Umea, Sweden.
    Kingham, Paul J
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Novikov, Lev N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Norrlands Univ Hosp, Sect Hand & Plast Surg, Dept Surg & Perioperat Sci, Umea, Sweden.
    Novikova, Liudmila N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Long-Term Effects of Fibrin Conduit with Human Mesenchymal Stem Cells and Immunosuppression after Peripheral Nerve Repair in a Xenogenic Model2018In: Cell Medicine, ISSN 2155-1790, Vol. 10, p. 1-13Article in journal (Refereed)
    Abstract [en]

    Introduction: Previously we showed that a fibrin glue conduit with human mesenchymal stem cells (hMSCs) and cyclosporine A (CsA) enhanced early nerve regeneration. In this study long term effects of this conduit are investigated. Methods: In a rat model, the sciatic nerve was repaired with fibrin conduit containing fibrin matrix, fibrin conduit containing fibrin matrix with CsA treatment and fibrin conduit containing fibrin matrix with hMSCs and CsA treatment, and also with nerve graft as control. Results: At 12 weeks 34% of motoneurons of the control group regenerated axons through the fibrin conduit. CsA treatment alone or with hMSCs resulted in axon regeneration of 67% and 64% motoneurons respectively. The gastrocnemius muscle weight was reduced in the conduit with fibrin matrix. The treatment with CsA or CsA with hMSCs induced recovery of the muscle weight and size of fast type fibers towards the levels of the nerve graft group. Discussion: The transplantation of hMSCs for peripheral nerve injury should be optimized to demonstrate their beneficial effects. The CsA may have its own effect on nerve regeneration.

  • 9.
    McGrath, Aleksandra M.
    et al.
    Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery. Department of Hand and Plastic Surgery, Norrland’s University Hospital, Umeå, Sweden.
    Lu, Johnny Chuieng-Yi
    Chang, Tommy Naj-Jen
    Fang, Frank
    Chuang, David Chwei-Chin
    Proximal versus distal nerve transfer for biceps reinnervation: a comparative study in a rat’s brachial plexus injury model2016In: Plastic and Reconstructive Surgery Global Open, ISSN 2169-7574, Vol. 4, no 12, article id e1130Article in journal (Refereed)
    Abstract [en]

    BACKGROUND: The exact role of proximal and distal nerve transfers in reconstruction strategies of brachial plexus injury remains controversial. We compared proximal with distal nerve reconstruction strategies in a rat model of brachial plexus injury.

    METHODS: In rats, the C6 spinal nerve with a nerve graft (proximal nerve transfer model, n = 30, group A) and 50% of ulnar nerve (distal nerve transfer model, n = 30, group B) were used as the donor nerves. The targets were the musculocutaneous nerve and the biceps muscle. Outcomes were recorded at 4, 8, 12, and 16 weeks postoperatively. Outcome parameters included grooming test, biceps muscle weight, compound muscle action potentials, tetanic contraction force, and axonal morphology of the donor and target nerves.

    RESULTS: The axonal morphology of the 2 donor nerves revealed no significant difference. Time interval analysis in the proximal nerve transfer group showed peak axon counts at 12 weeks and a trend of improvement in all functional and physiologic parameters across all time points with statistically significant differences for grooming test, biceps compound action potentials, tetanic muscle contraction force, and muscle weight at 16 weeks. In contrast, in the distal nerve transfer group, the only statistically significant difference was observed between the 4 and 8 week time points, followed by a plateau from 8 to 16 weeks.

    CONCLUSIONS: Outcomes of proximal nerve transfers are ultimately superior to distal nerve transfers in our experimental model. Possible explanations for the superior results include a reduced need for cortical adaptation and higher proportions of motor units in the proximal nerve transfers.

  • 10.
    McGrath, Aleksandra M
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Novikova, Liudmila N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Novikov, Lev N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    BD™ PuraMatrix™ peptide hydrogel seeded with Schwann cells for peripheral nerve regeneration2010In: Brain Research Bulletin, ISSN 0361-9230, E-ISSN 1873-2747, Vol. 83, no 5, p. 207-213Article in journal (Refereed)
    Abstract [en]

    This study investigated the effects of a membrane conduit filled with a synthetic matrix BD™ PuraMatrix™ peptide (BD) hydrogel and cultured Schwann cells on regeneration after peripheral nerve injury in adult rats. After sciatic axotomy, a 10mm gap between the nerve stumps was bridged using ultrafiltration membrane conduits filled with BD hydrogel or BD hydrogel containing Schwann cells. In control experiments, the nerve defect was bridged using either membrane conduits with alginate/fibronectin hydrogel or autologous nerve graft. Axonal regeneration within the conduit was assessed at 3 weeks and regeneration of spinal motoneurons and recovery of muscle weight evaluated at 16 weeks postoperatively. Schwann cells survived in the BD hydrogel both in culture and after transplantation into the nerve defect. Regenerating axons grew significantly longer distances within the conduits filled with BD hydrogel when compared with the alginate/fibronectin hydrogel and alginate/fibronectin with Schwann cells. Addition of Schwann cells to the BD hydrogel considerably increased regeneration distance with axons crossing the injury gap and entering into the distal nerve stump. The conduits with BD hydrogel showed a linear alignment of nerve fibers and Schwann cells. The number of regenerating motoneurons and recovery of the weight of the gastrocnemius muscle was inferior in BD hydrogel and alginate/fibronectin groups compared with nerve grafting. Addition of Schwann cells did not improve regeneration of motoneurons or muscle recovery. The present results suggest that BD hydrogel with Schwann cells could be used within biosynthetic conduits to increase the rate of axonal regeneration across a nerve defect.

  • 11.
    Pettersson, Jonas
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Kalbermatten, Daniel
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    McGrath, Aleksandra
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Novikova, Liudmila N
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Biodegradable fibrin conduit promotes long-term regeneration after peripheral nerve injury in adult rats2010In: Journal of Plastic, Reconstructive & Aesthetic Surgery, ISSN 1748-6815, E-ISSN 1532-1959, Vol. 63, no 11, p. 1893-1899Article in journal (Refereed)
    Abstract [en]

    Peripheral nerve injuries are often associated with loss of nerve tissue and require autologous nerve grafts to provide a physical substrate for axonal growth. Biosynthetic neural conduits could be an alternative treatment strategy in such injuries. The present study investigates the long-term effects of a tubular fibrin conduit on neuronal regeneration, axonal sprouting and recovery of muscle weight following peripheral nerve injury and repair in adult rats. Sciatic axotomy was performed proximally in the thigh to create a 10-mm gap between the nerve stumps. The injury gap was bridged by using a 14-mm-long fibrin glue conduit, entubulating 2mm of the nerve stump at each end. A reversed autologous nerve graft was used as a control. The regenerative response from sensory and motor neurones was evaluated following retrograde labelling with Fast Blue fluorescent tracer. In control experiments, at 16 weeks following peripheral nerve grafting, 5184 (+/-574 standard error of mean (SEM)) sensory dorsal root ganglion neurones and 1001 (+/-37 SEM) spinal motor neurones regenerated across the distal nerve-graft interface. The fibrin conduit promoted regeneration of 60% of sensory neurones and 52% of motor neurones when compared to the control group. The total number of myelinated axons in the distal nerve stump in the fibrin-conduit group reached 86% of the control and the weight of gastrocnemius and soleus muscles recovered to 82% and 89% of the controls, respectively. The present results suggest that a tubular fibrin conduit can be used to promote neuronal regeneration following peripheral nerve injury.

  • 12.
    Pettersson, Jonas
    et al.
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    McGrath, Aleksandra
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Kalbermatten, Daniel
    University Hospital of Basel.
    Novikova, Liudmila
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Wiberg, Mikael
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Hand Surgery.
    Kingham, Paul
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Novikov, Lev
    Umeå University, Faculty of Medicine, Department of Integrative Medical Biology (IMB), Anatomy.
    Muscle recovery after repair of short and long peripheral nerve gaps using fibrin conduits2011In: Neuroscience Letters, ISSN 0304-3940, E-ISSN 1872-7972, Vol. 500, no 1, p. 41-46Article in journal (Refereed)
    Abstract [en]

    Peripheral nerve injuries with loss of nervous tissue are a significant clinical problem and are currently treated using autologous nerve transplants. To avoid the need for donor nerve, which results in additional morbidity such as loss of sensation and scarring, alternative bridging methods have been sought. Recently we showed that an artificial nerve conduit moulded from fibrin glue is biocompatible to nerve regeneration. In this present study, we have used the fibrin conduit or a nerve graft to bridge either a 10 mm or 20 mm sciatic nerve gap and analyzed the muscle recovery in adult rats after 16 weeks. The gastrocnemius muscle weights of the operated side were similar for both gap sizes when treated with nerve graft. In contrast, muscle weight was 48.32 ± 4.96% of the contra-lateral side for the 10 mm gap repaired with fibrin conduit but only 25.20 ± 2.50% for the 20 mm gap repaired with fibrin conduit. The morphology of the muscles in the nerve graft groups showed an intact, ordered structure, with the muscle fibers grouped in fascicles whereas the 20 mm nerve gap fibrin group had a more chaotic appearance. The mean area and diameter of fast type fibers in the 20 mm gap repaired with fibrin conduits were significantly (P < 0.01) worse than those of the corresponding 10 mm gap group. In contrast, both gap sizes treated with nervegraft showed similar fiber size. Furthermore, the 10 mm gaps repaired with either nerve graft or fibrin conduit showed similar muscle fiber size. These results indicate that the fibrin conduit can effectively treat short nerve gaps but further modification such as the inclusion of regenerative cells may be required to attain the outcomes of nerve graft for long gaps.

1 - 12 of 12
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf