umu.sePublikationer
Ändra sökning
Avgränsa sökresultatet
1 - 41 av 41
RefereraExporteraLänk till träfflistan
Permanent länk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Träffar per sida
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Författare A-Ö
  • Författare Ö-A
  • Titel A-Ö
  • Titel Ö-A
  • Publikationstyp A-Ö
  • Publikationstyp Ö-A
  • Äldst först
  • Nyast först
  • Skapad (Äldst först)
  • Skapad (Nyast först)
  • Senast uppdaterad (Äldst först)
  • Senast uppdaterad (Nyast först)
  • Disputationsdatum (tidigaste först)
  • Disputationsdatum (senaste först)
  • Standard (Relevans)
  • Författare A-Ö
  • Författare Ö-A
  • Titel A-Ö
  • Titel Ö-A
  • Publikationstyp A-Ö
  • Publikationstyp Ö-A
  • Äldst först
  • Nyast först
  • Skapad (Äldst först)
  • Skapad (Nyast först)
  • Senast uppdaterad (Äldst först)
  • Senast uppdaterad (Nyast först)
  • Disputationsdatum (tidigaste först)
  • Disputationsdatum (senaste först)
Markera
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1. Antoni, Gunnar
    et al.
    Lubberink, Mark
    Estrada, Sergio
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Carlson, Kristina
    Lindsjö, Lars
    Kero, Tanja
    Långström, Bengt
    Granstam, Sven-Olof
    Rosengren, Sara
    Vedin, Ola
    Wassberg, Cecilia
    Wikstrom, Gerhard
    Westermark, Per
    Sörensen, Jens
    In Vivo Visualization of Amyloid Deposits in the Heart with C-11-PIB and PET2013Ingår i: Journal of Nuclear Medicine, ISSN 0161-5505, E-ISSN 1535-5667, Vol. 54, nr 2, s. 213-220Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Cardiac amyloidosis is a differential diagnosis in heart failure and is associated with high mortality. There is currently no noninvasive imaging test available for specific diagnosis. N-[methyl-C-11]2-(4'-methylamino-phenyl)-6-hydroxybenzothiazole (C-11-PIB) PET is used in the evaluation of brain amyloidosis. We evaluated the potential use of C-11-PIB PET in systemic amyloidosis affecting the heart. Methods: Patients (n = 10) diagnosed with systemic amyloidosis-including heart involvement of either monoclonal immunoglobulin light-chain (AL) or transthyretin (ATTR) type- and healthy volunteers (n = 5) were investigated with PET/CT using C-11-PIB to study cardiac amyloid deposits and with C-11-acetate to measure myocardial blood flow to study the impact of global and regional perfusion on PIB retention. Results: Myocardial C-11-PIB uptake was visually evident in all patients 15-25 min after injection and was not seen in any volunteer. A significant difference in C-11-PIB retention in the heart between patients and healthy controls was found. The data indicate that myocardial amyloid deposits in patients diagnosed with systemic amyloidosis could be visualized with C-11-PIB. No correlation between C-11-PIB retention index and myocardial blood flow as measured with C-11-acetate was found on the global level, whereas a positive correlation on the segmental level was seen in a single patient. Conclusion: C-11-PIB and PET could be a method to study systemic amyloidosis of type AL and ATTR affecting the heart and should be investigated further both as a diagnostic tool and as a noninvasive method for treatment follow-up.

  • 2.
    Asklund, Thomas
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Henriksson, Roger
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Bergström, Åsa
    Kasper, Maria
    Ögren, Margareta
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Toftgård, Rune
    Riklund, Katrine Åhlström
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Early and persisting response to vismodegib in a patient with bone metastasizing medulloblastoma2013Ingår i: Acta Oncologica, ISSN 0284-186X, E-ISSN 1651-226X, Vol. 52, nr 4, s. 862-865Artikel i tidskrift (Refereegranskat)
  • 3.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Imlook4d: introducing an extendable research 4d analysis software2014Ingår i: XII Turku PET Symposium, 24-27 May 2014, Turku, Finland: the symposium of Nordic Association for Clinical Physics (NACP), 2014, s. 63-63Konferensbidrag (Övrigt vetenskapligt)
    Abstract [en]

    Imlook4d (http://www.dicom-port.com) is a free Matlab based graphical user interface (GUI) tool useful for static, dynamic and gated PET studies.  It supports reading and writing DICOM, Nifti, Analyze, ECAT.  The DICOM reader is orders of magnitude faster than the Matlab imaging toolbox.  Imlook4d requires no additional Matlab toolboxes.

    The main benefit with imlook4d is that it is easily extendable with scripts, accessing exported variables such as the image matrix (4D) and a region-of-interest (ROI) matrix.  Scripts are available via a menu in the imlook4d GUI, and can be used to manipulate the image-matrix and ROI data.  There is also a menu option to export and import these variables to the Matlab workspace for interactive manipulation, useful for one-off fixes or for script development.  There are presently about 30 scripts in categories such as ROI, Matrix, Header info etc.  There is also direct export to ImageJ [1] and import back from ImageJ, thus giving access to all tools available within ImageJ.

    Imlook4d has a built in volume-of-interest editor, with a brush tool for quick interactive ROI delineation, and via scripts, different ways of thresholding ROIs from parts of the image.  Time activity data is saved to a tab-delimited text file.

    The principal-component (PC) based Hotelling filter is an integrated part of the program, which allows for interactive noise reduction without loss of quantitation [2].  A typical work flow for a dynamic data set is to turn on the filter for ROI delineation, and then there is the choice of turning it off for export of time-activity data.  Also the PC images can be used to draw ROIs on, which under some circumstances gives enhanced contrast.

    Calculation of parametric pharmacokinetic modelling images can be performed interactively, calculated slice by slice as the user scrolls through the volume.  Reference models for Patlak, Logan and Averaged Simple Flow Model [3]  applied on 15O-water are implemented, and it is relatively easy to implement other kinetic models.  Similarly, scripts have been developed for regional Patlak and Logan models on ROI data.

    [1] Rasband, WS, ImageJ, U. S. National Institutes of Health, Bethesda, Maryland, USA, http://imagej.nih.gov/ij/, 1997-2014

    [2] Axelsson J, Sörensen J, The 2D Hotelling filter - a quantitative noise-reducing principal-component filter for dynamic PET data, with applications in patient dose reduction. BMC Med Phys. 2013 Apr 10;13:1. doi: 10.1186/1756-6649-13-1.

    [3] Yoshida, K, Mullani, N and Gould KL, Coronary Flow and Flow Reserve by PET Simplified for Clinical Applications Using Rubidium-82 or Nitrogen-13-Ammonia, J Nucl Med 1996; 37:1701-1712

    Figure 1.  The imlook4d GUI with the user SCRIPTS menu selected.  The group of ROI scripts was further selected.  In the underlying image, a rough ROI is created.  

  • 4.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    PET/MR ur fysikerns perspektiv2015Konferensbidrag (Övrigt vetenskapligt)
  • 5.
    Axelsson, Jan
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Sörensen, Jens
    PET-center, Department of Radiology, Oncology and Radiation Sciences, Uppsala University, Uppsala, Sweden.
    The 2D Hotelling filter: a quantitativenoise-reducing principal-component filter fordynamic PET data, with applications in patientdose reduction2013Ingår i: BMC Medical Physics, ISSN 1756-6649, Vol. 13, nr 1Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Background: In this paper we apply the principal-component analysis filter (Hotelling filter) to reduce noise fromdynamic positron-emission tomography (PET) patient data, for a number of different radio-tracer molecules. Wefurthermore show how preprocessing images with this filter improves parametric images created from suchdynamic sequence.We use zero-mean unit variance normalization, prior to performing a Hotelling filter on the slices of a dynamictime-series. The Scree-plot technique was used to determine which principal components to be rejected in thefilter process. This filter was applied to [11C]-acetate on heart and head-neck tumors, [18F]-FDG on liver tumors andbrain, and [11C]-Raclopride on brain. Simulations of blood and tissue regions with noise properties matched to realPET data, was used to analyze how quantitation and resolution is affected by the Hotelling filter. Summing varyingparts of a 90-frame [18F]-FDG brain scan, we created 9-frame dynamic scans with image statistics comparable to 20MBq, 60 MBq and 200 MBq injected activity. Hotelling filter performed on slices (2D) and on volumes (3D) werecompared.Results: The 2D Hotelling filter reduces noise in the tissue uptake drastically, so that it becomes simple to manuallypick out regions-of-interest from noisy data. 2D Hotelling filter introduces less bias than 3D Hotelling filter in focalRaclopride uptake. Simulations show that the Hotelling filter is sensitive to typical blood peak in PET prior to tissueuptake have commenced, introducing a negative bias in early tissue uptake. Quantitation on real dynamic data isreliable. Two examples clearly show that pre-filtering the dynamic sequence with the Hotelling filter prior toPatlak-slope calculations gives clearly improved parametric image quality. We also show that a dramatic dosereduction can be achieved for Patlak slope images without changing image quality or quantitation.Conclusions: The 2D Hotelling-filtering of dynamic PET data is a computer-efficient method that gives visuallyimproved differentiation of different tissues, which we have observed improve manual or automated regionof-interest delineation of dynamic data. Parametric Patlak images on Hotelling-filtered data display improved clarity,compared to non-filtered Patlak slope images without measurable loss of quantitation, and allow a dramaticdecrease in patient injected dose.

  • 6.
    Brynolfsson, Patrik
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Holmberg, August
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Jonsson, Joakim
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Goldhaber, David
    Jian, Yiqiang
    Illerstam, Fredrik
    Engström, Mathias
    Zackrisson, Björn
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Nyholm, Tufve
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Technical note: adapting a GE SIGNA PET/MR scanner for radiotherapy2018Ingår i: Medical physics (Lancaster), ISSN 0094-2405, Vol. 45, nr 8, s. 3546-3550Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Purpose: Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. Method: A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. Result: We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. Conclusion: We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.

  • 7. Chen, Hanwei
    et al.
    Jiang, Jinzhao
    Gao, Junling
    Liu, Dan
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Cui, Minyi
    Gong, Nan-Jie
    Feng, Shi-Ting
    Luo, Liangping
    Huang, Bingsheng
    Tumor Volumes Measured From Static and Dynamic F-18-fluoro-2-deoxy-D-glucose Positron Emission Tomography-Computed Tomography Scan: Comparison of Different Methods Using Magnetic Resonance Imaging as the Criterion Standard2014Ingår i: Journal of computer assisted tomography, ISSN 0363-8715, E-ISSN 1532-3145, Vol. 38, nr 2, s. 209-215Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Objective: The objective of this study was to compare the accuracy of calculating the primary tumor volumes using a gradient-based method and fixed threshold methods on the standardized uptake value (SUV) maps and the net influx of FDG (Ki) maps from positron emission tomography-computed tomography (PET-CT) images. Materials and Methods: Newly diagnosed patients with head and neck cancer were recruited, and dynamic PET-CT scan and T2-weighted magnetic resonance imaging were performed. The maps of Ki and SUV were calculated from PET-CT images. The tumor volumes were calculated using a gradient-based method and a fixed threshold method at 40% of maximal SUV or maximal Ki. Four kinds of volumes, VOLKi-Gra (from the Ki maps using the gradient-based method), VOLKi-40% (from the Ki maps using the threshold of 40% maximal Ki), VOLSUV-Gra (from the SUV maps using the gradient-based method), and VOLSUV-40% (from the SUV maps using the threshold of 40% maximal SUV), were acquired and compared with VOLMRI (the volumes acquired on T2-weighted images) using the Pearson correlation, paired t test, and similarity analysis. Results: Eighteen patients were studied, of which 4 had poorly defined tumors (PDT). The positron emission tomography-derived volumes were as follows: VOLSUV-40%, 2.1 to 41.2 cm(3) (mean [SD], 12.3 [10.6]); VOLSUV-Gra, 2.2 to 28.1 cm(3) (mean [SD], 13.2 [8.4]); VOLKi-Gra, 2.4 to 17.0 cm(3) (mean [SD], 9.5 [4.6]); and VOLKi-40%, 2.7 to 20.3 cm(3) (mean [SD], 12.0 [6.0]). The VOLMRI ranged from 2.9 to 18.1 cm(3) (mean [SD], 9.1 [3.9]). The VOLKi-Gra significantly correlated with VOLMRI with the highest correlation coefficient (PDT included, R = 0.673, P = 0.002; PDT excluded, R = 0.841, P < 0.001) and presented no difference from VOLMRI (P = 0.672 or 0.561, respectively, PDT included and excluded). The difference between VOLKi-Gra and VOLMRI was also the smallest. Conclusions: The tumor volumes delineated on the Ki maps using the gradient-based method are more accurate than those on the SUV maps and using the fixed threshold methods.

  • 8. de Boer, Lieke
    et al.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Chowdhury, Rumana
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Dolan, Raymond J.
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB), Fysiologi.
    Backman, Lars
    Guitart-Masip, Marc
    Dorsal striatal dopamine D1 receptor availability predicts an instrumental bias in action learning2019Ingår i: Proceedings of the National Academy of Sciences of the United States of America, ISSN 0027-8424, E-ISSN 1091-6490, Vol. 116, nr 1, s. 261-270Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Learning to act to obtain reward and inhibit to avoid punishment is easier compared with learning the opposite contingencies. This coupling of action and valence is often thought of as a Pavlovian bias, although recent research has shown it may also emerge through instrumental mechanisms. We measured this learning bias with a rewarded go/no-go task in 60 adults of different ages. Using computational modeling, we characterized the bias as being instrumental. To assess the role of endogenous dopamine (DA) in the expression of this bias, we quantified DA D1 receptor availability using positron emission tomography (PET) with the radioligand [11C]SCH23390. Using principal-component analysis on the binding potentials in a number of cortical and striatal regions of interest, we demonstrated that cortical, dorsal striatal, and ventral striatal areas provide independent sources of variance in DA D1 receptor availability. Interindividual variation in the dorsal striatal component was related to the strength of the instrumental bias during learning. These data suggest at least three anatomical sources of variance in DA D1 receptor availability separable using PET in humans, and we provide evidence that human dorsal striatal DA D1 receptors are involved in the modulation of instrumental learning biases.

  • 9. de Boer, Lieke
    et al.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Dayan, Peter
    Backman, Lars
    Guitart-Masip, Marc
    Attenuation of dopamine-modulated prefrontal value signals underlies probabilistic reward learning deficits in old age2017Ingår i: eLIFE, E-ISSN 2050-084X, Vol. 6, artikel-id e2642Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Probabilistic reward learning is characterised by individual differences that become acute in aging. This may be due to age-related dopamine (DA) decline affecting neural processing in striatum, prefrontal cortex, or both. We examined this by administering a probabilistic reward learning task to younger and older adults, and combining computational modelling of behaviour, fMRI and PET measurements of DA D1 availability. We found that anticipatory value signals in ventromedial prefrontal cortex (vmPFC) were attenuated in older adults. The strength of this signal predicted performance beyond age and was modulated by D1 availability in nucleus accumbens. These results uncover that a value-anticipation mechanism in vmPFC declines in aging, and that this mechanism is associated with DA D1 receptor availability.

  • 10.
    Holmberg, Daniel
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Sundström, Torbjörn
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Ljungberg, Michael
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Reducing Scanning Time to 50% for In-111 Pentetreotide SPECT When Using Model-Based Compensation2012Ingår i: 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) / [ed] B. Yu, 2012, s. 2946-2949Konferensbidrag (Refereegranskat)
    Abstract [en]

    In In-111-pentetreotide SPECT, it can be difficult to detect small tumors because of high noise levels and low spatial resolution. The aim of this study was to perform optimization of tumor detection in the liver, with regards to the acquisition and reconstruction protocol for In-111-pentetreotide SPECT with model-based compensation included in the OSEM reconstruction. We were also interested in the effect of performing the examination in half of the time or with half the administered activity. Image reconstruction without model-based compensation was also included for comparison. The study concentrates on the acquired number of projections and the subset size in the OSEM reconstruction, and evaluates contrast as a function of noise for a range of OSEM iterations. The raw-data projections are produced using Monte Carlo simulations of a patient-like anthropomorphic phantom with realistic In-111 pentetreotide uptake, including spherical tumors in the liver. Two collimators are evaluated, the extended low-energy general-purpose (ELEGP) and the medium-energy general-purpose (MEGP) collimator. ELEGP proved to be a better collimator when using model-based compensation. The results also indicate that a relatively low number of subsets is advantageous, and that 60 projection angles or even lower is a better choice than 120. For both collimators the time-reduced scan including model-based compensation was better compared to the full-time reconstructions without model-based compensation.

  • 11.
    Häggström, Ida
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Schmidtlein, Ross
    Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York 10065, USA.
    Karlsson, Mikael
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Garpebring, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Johansson, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Sörensen, Jens
    Medical Sciences, Nuclear Medicine, Uppsala University Hospital, Uppsala, Sweden.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    A Monte Carlo study of the dependence of early frame sampling on uncertainty and bias in pharmacokinetic parameters from dynamic PET2015Ingår i: Journal of Nuclear Medicine Technology, ISSN 0091-4916, E-ISSN 1535-5675, Vol. 43, nr 1, s. 53-60Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Compartmental modeling of dynamic PET data enables quantifi- cation of tracer kinetics in vivo, through the calculated model parameters. In this study, we aimed to investigate the effect of early frame sampling and reconstruction method on pharmacokinetic parameters obtained from a 2-tissue model, in terms of bias and uncertainty (SD). Methods: The GATE Monte Carlo software was used to simulate 2 · 15 dynamic 3′-deoxy-3′-18F-fluorothymidine (18F-FLT) brain PET studies, typical in terms of noise level and kinetic parameters. The data were reconstructed by both 3- dimensional (3D) filtered backprojection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM) into 6 dynamic image sets with different early frame durations of 1, 2, 4, 6, 10, and 15 s. Bias and SD were evaluated for fitted parameter estimates, calculated from regions of interest. Results: The 2-tissue-model parameter estimates K1, k2, and fraction of arterial blood in tissue depended on early frame sampling, and a sampling of 6–15 s generally minimized bias and SD. The shortest sampling of 1 s yielded a 25% and 42% larger bias than the other schemes, for 3DRP and OSEM, respectively, and a parameter uncertainty that was 10%–70% higher. The schemes from 4 to 15 s were generally not significantly different in regards to bias and SD. Typically, the reconstruction method 3DRP yielded less framesampling dependence and less uncertain results, compared with OSEM, but was on average more biased. Conclusion: Of the 6 sampling schemes investigated in this study, an early frame duration of 6–15 s generally kept both bias and uncertainty to a minimum, for both 3DRP and OSEM reconstructions. Veryshort frames of 1 s should be avoided because they typically resulted in the largest parameter bias and uncertainty. Furthermore, 3DRP may be p

  • 12.
    Häggström, Ida
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Garpebring, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Johansson, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Schmidtlein, C. Ross
    Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA.
    Sörensen, Jens
    Medical Sciences, Nuclear Medicine, Uppsala University Hospital, Uppsala, Sweden.
    Karlsson, Mikael
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    The influence of time sampling scheme on kinetic parameters obtained from compartmental modeling of a dynamic PET study: a Monte Carlo study2012Ingår i: IEEE Nuclear Science Symposium Conference Record / [ed] B. Yu, Anaheim: IEEE conference proceedings, 2012, s. 3101-3107Konferensbidrag (Refereegranskat)
    Abstract [en]

    Compartmental modeling of dynamic PET data enables quantification of tracer kinetics in vivo, through the obtained model parameters. The dynamic data is sorted into frames during or after the acquisition, with a sampling interval usually ranging from 10 s to 300 s. In this study we wanted to investigate the effect of the chosen sampling interval on kinetic parameters obtained from a 2-tissue model, in terms of bias and standard deviation, using a complete Monte Carlo simulated dynamic F-18-FLT PET study. The results show that the bias and standard deviation in parameter K-1 is small regardless of sampling scheme or noise in the time-activity curves (TACs), and that the bias and standard deviation in k(4) is large for all cases. The bias in V-a is clearly dependent on sampling scheme, increasing for increased sampling interval. In general, a too short sampling interval results in very noisy images and a large bias of the parameter estimate, and a too long sampling interval also increases bias. Noise in the TACs is the largest source of bias.

  • 13.
    Jakobson Mo, Susanna
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Jonasson, Lars
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Ögren, Mattias J.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Ögren, Margareta
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Varrone, Andrea
    Eriksson, Linda
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Bäckström, David
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    af Bjerkén, Sara
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Linder, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Dopamine transporter imaging with [18F]FE-PE2I PET and [123I]FP-CIT SPECT – a clinical comparison2018Ingår i: EJNMMI Research, ISSN 2191-219X, E-ISSN 2191-219X, Vol. 8, artikel-id 100Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Background: Dopamine transporter (DAT) imaging may be of diagnostic value in patients with clinically suspected parkinsonian disease. The purpose of this study was to compare the diagnostic performance of DAT imaging with positron emission computed tomography (PET), using the recently developed, highly DAT-selective radiopharmaceutical [18F]FE-PE2I (FE-PE2I), to the commercially available and frequently used method with [123I]FP-CIT (FP-CIT) single-photon emission computed tomography (SPECT) in early-stage idiopathic parkinsonian syndrome (PS).

    Methods: Twenty-two patients with a clinical de novo diagnosis of PS and 28 healthy controls (HC) participating in an on-going clinical trial of FE-PE2I were analyzed in this study. Within the trial protocol, participants are clinically reassessed 2 years after inclusion. A commercially available software was used for automatic calculation of FP-CIT-specific uptake ratio (SUR). MRI-based volumes of interest combined with threshold PET segmentation were used for FE-PE2I binding potential relative to non-displaceable binding (BPND) quantification and specific uptake value ratios (SUVR).

    Results: PET with FE-PE2I revealed significant differences between patients with a clinical de novo diagnosis of PS and healthy controls in striatal DAT availability (p < 0.001), with excellent accuracy of predicting dopaminergic deficit in early-stage PS. The effect sizes were calculated for FE-PE2I BPND (Glass’s Δ = 2.95), FE-PE2I SUVR (Glass’s Δ = 2.57), and FP-CIT SUR (Glass’s Δ = 2.29). The intraclass correlation (ICC) between FE-PE2I BPND FP-CIT SUR was high in the caudate (ICC = 0.923), putamen (ICC = 0.922), and striatum (ICC = 0.946), p < 0.001. Five of the 22 patients displayed preserved striatal DAT availability in the striatum with both methods. At follow-up, a non-PS clinical diagnosis was confirmed in three of these, while one was clinically diagnosed with corticobasal syndrome. In these patients, FE-PE2I binding was also normal in the substantia nigra (SN), while significantly reduced in the remaining patients. FE-PE2I measurement of the mean DAT availability in the putamen was strongly correlated with BPND in the SN (R = 0.816, p < 0.001). Olfaction and mean putamen DAT availability was correlated using both FE-PE2I BPND and FP-CIT SUR (R ≥ 0.616, p < 0.001).

    Conclusion: DAT imaging with FE-PE2I PET yields excellent basic diagnostic differentiation in early-stage PS, at least as good as FP-CIT SPECT.

  • 14.
    Jonasson, Lars
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR).
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Boraxbekk, Carl-Johan
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR). Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital, Hvidovre, Denmark.
    Simulating effects of brain atrophy in longitudinal PET imaging with an anthropomorphic brain phantom2017Ingår i: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 62, nr 13, s. 5213-5227Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    In longitudinal positron emission tomography (PET), the presence of volumetric changes over time can lead to an overestimation or underestimation of the true changes in the quantified PET signal due to the partial volume effect (PVE) introduced by the limited spatial resolution of existing PET cameras and reconstruction algorithms. Here, a 3D-printed anthropomorphic brain phantom with attachable striata in three sizes was designed to enable controlled volumetric changes. Using a method to eliminate the non-radioactive plastic wall, and manipulating BP levels by adding different number of events from list-mode acquisitions, we investigated the artificial volume dependence of BP due to PVE, and potential bias arising from varying BP. Comparing multiple reconstruction algorithms we found that a high-resolution ordered- subsets maximization algorithm with spatially variant point-spread function resolution modeling provided the most accurate data. For striatum, the BP changed by 0.08% for every 1% volume change, but for smaller volumes such as the posterior caudate the artificial change in BP was as high as 0.7% per 1% volume change. A simple gross correction for striatal volume is unsatisfactory, as the amplitude of the PVE on the BP differs depending on where in the striatum the change occurred. Therefore, to correctly interpret age-related longitudinal changes in the BP, we must account for volumetric changes also within a structure, rather than across the whole volume. The present 3D-printing technology, combined with the wall removal method, can be implemented to gain knowledge about the predictable bias introduced by the PVE differences in uptake regions of varying shape.

  • 15.
    Jonasson, Lars
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR).
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Kramer, Arthur F
    Departments of Psychology and Mechanical and Industrial Engineering, Northeastern University, Boston, MA, USA.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Boraxbekk, Carl-Johan
    Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Danish Research Centre for Magnetic Resonance, Copenhagen University Hospital, Hvidovre, Denmark..
    Aerobic fitness influences working memory updating via the striatal dopaminergic system in older adultsManuskript (preprint) (Övrigt vetenskapligt)
    Abstract [en]

    There is much evidence that dopamine is vital for cognitive functioning in aging. Here we tested the hypothesis that aerobic exercise and fitness influences dopaminergic neurotransmission in the striatum as measured by positron emission tomography (PET) and the non-displacable binding potential (BPND ) of [11C]raclopride, and in turn performance on offline working-memory updating tasks. In a sample of 58 older sedentary adults undergoing a six-months exercise intervention, aerobic exercise compared to stretching, toning, and resistance training did not have a differential effect on BPND . At baseline, higher aerobic fitness levels (VO2peak ) were associated with higher BPND  in the striatum. Following the intervention, for both forms of training, we found reduced BPND , indicating increased dopamine (DA), in a cluster in the anterior striatum in individuals with larger improvements in VO2peak . This reduction in BPND  mediated a positive indirect effect of VO2peak  on working-memory updating performance. Collectively these findings implicate DA as a neurocognitive mechanism explaining the positive effects of staying physically active at an old age for working memory.

  • 16.
    Jonasson, Lars S.
    et al.
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Samhällsvetenskapliga fakulteten, Centrum för befolkningsstudier (CBS).
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Braver, Todd S.
    Department of Psychology,Washington University, St Louis, MO 63130, USA.
    Ögren, Mattias
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Bäckman, Lars
    Aging Research Center, Karolinska Institute, SE-113 30 Stockholm, Sweden.
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB), Fysiologi.
    Dopamine release in nucleus accumbens during rewarded task switching measured by [11C]raclopride2014Ingår i: NeuroImage, ISSN 1053-8119, E-ISSN 1095-9572, Vol. 99, s. 357-364Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Reward and motivation have positive influences on cognitive-control processes in numerous settings. Models of reward implicate corticostriatal loops and the dopamine (DA) system, with special emphasis on D2 receptors in nucleus accumbens (NAcc). In this study, 11 right-handed males (35-40 years) were scanned with positron emission tomography (PET) in a single [(11)C]raclopride dynamic scan during rewarded and non-rewarded task switching. Rewarded task switching (relative to baseline task switching) decreased [(11)C]raclopride binding in NAcc. Decreasing NAcc [(11)C]raclopride binding was strongly associated with task reaction time measures that reflect individual differences in effort and control strategies. Voxelwise analyses additionally revealed reward-related DA release in anterodorsal caudate, a region previously associated with task-switching. These PET findings provide evidence for striatal DA release during motivated cognitive control, and further suggest that NAcc DA release predicts the task reaction time benefits of reward incentives.

  • 17.
    Jonasson, Lars S.
    et al.
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Kramer, Arthur F.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Boraxbekk, Carl-Johan
    Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Danish Research Centre for Magnetic Resonance, Copenhagen University Hospital, Hvidovre, Denmark.
    Higher striatal D2-receptor availability in aerobically fit older adults but non-selective intervention effects after aerobic versus resistance training2019Ingår i: NeuroImage, ISSN 1053-8119, E-ISSN 1095-9572, Vol. 202, artikel-id 116044Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    There is much evidence that dopamine is vital for cognitive functioning in aging. Here we tested the hypothesis that aerobic exercise and fitness influence dopaminergic neurotransmission in the striatum, and in turn performance on offline working-memory updating tasks. Dopaminergic neurotransmission was measured by positron emission tomography (PET) and the non-displacable binding potential (BPND) of [11C]raclopride, i.e. dopamine (DA) D2-receptor (D2R) availability. Fifty-four sedentary older adults underwent a six-months exercise intervention, performing either aerobic exercise or stretching, toning, and resistance active control training. At baseline, higher aerobic fitness levels (VO2peak) were associated with higher BPND in the striatum, providing evidence of a link between an objective measure of aerobic fitness and D2R in older adults. BPND decreased substantially over the intervention in both groups but the intervention effects were non-selective with respect to exercise group. The decrease was several times larger than any previously estimated annual decline in D2R, potentially due to increased endogenous DA. Working-memory was unrelated to D2R both at baseline and following the intervention. To conclude, we provide partial evidence for a link between physical exercise and DA. Utilizing a PET protocol able to disentangle both D2R and DA levels could shed further light on whether, and how, aerobic exercise impacts the dopaminergic system in older adults.

  • 18.
    Jonsson, Per
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Lindmark, Lorentz
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Avdelningen för medicin.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Karlsson, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Avdelningen för medicin.
    Lundberg, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Stegmayr, Bernd
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers2018Ingår i: Artificial Organs, ISSN 0160-564X, E-ISSN 1525-1594, Vol. 42, nr 5, s. 533-539Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    We were encouraged to investigate the reasons for large amounts of foam observed in bloodlines during hemodialysis (HD). Foam was visible in the venous air trap within the Artis Gambro dialysis device. Estimates of the extent of foam were graded (0no foam, 10extensive foam) by two persons that were blind to the type of dialyzer used. Thirty-seven patients were involved in the dialysis procedures. Consecutive dialyses were graded using dialyzers from Fresenius Medical Care (CorDiax dialyzers that were used for high flux HDFX80 and FX100, and for hemodiafiltrationFX1000). The extracorporeal circuit was primed automatically by dialysate using Gambro Artis software 8.15 006 (Gambro, Dasco, Medolla Italy, Baxter, Chicago, IL, USA). The priming volume recommended by the manufacturer was 1100 mL, whereas our center uses 1500 mL. Extensive amounts of blood foam were visual in the air traps. Although the manufacturer recommended extension of priming volume up to 3000 mL, this did not eliminate the foam. Microbubble measurement during HD revealed the air to derive from the dialyzers. When changing to PF210H dialyzers (Baxter) and using a priming volume of 1500 mL, the foam was significantly less (P<0.01). The extent of foam correlated with the size of the FX-dialyzer surface (P=0.002). The auto-priming program was updated to version 8.21 by the manufacturer and the extent of foam in the air trap using FX dialyzers was now reduced and there was no longer a difference between FX and PF dialyzers, although less foam was still visible in the venous air trap during several dialyses. In conclusion, this study urgently calls attention to blood foam development in the venous air trap when using Artis devices and priming software 8.15 in combination with Fresenius dialyzers. Updated auto-priming software (version 8.21) of Artis should be requested to reduce the extent of foam for the Fresenius dialyzers. Other interactions may also be present. We recommend further studies to clarify these problems. Meanwhile caution is warranted for the combined use of dialysis devices and dialyzers with incompatible automatic priming.

  • 19.
    Karalija, Nina
    et al.
    Umeå universitet.
    Papenberg, Goran
    Wåhlin, Anders
    Umeå universitet.
    Johansson, Jarkko
    Umeå universitet.
    Andersson, Micael
    Umeå universitet.
    Axelsson, Jan
    Umeå universitet.
    Riklund, Katrine
    Umeå universitet.
    Lövdén, Martin
    Lindenberger, Ulman
    Bäckman, Lars
    Nyberg, Lars
    Umeå universitet.
    C957T-mediated Variation in Ligand Affinity Affects the Association between C-11-raclopride Binding Potential and Cognition2019Ingår i: Journal of cognitive neuroscience, ISSN 0898-929X, E-ISSN 1530-8898, Vol. 31, nr 2, s. 314-325Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    The dopamine (DA) system plays an important role in cognition. Accordingly, normal variation in DA genes has been found to predict individual differences in cognitive performance. However, little is known of the impact of genetic differences on the link between empirical indicators of the DA system and cognition in humans. The present work used PET with C-11-raclopride to assess DA D2-receptor binding potential (BP) and links to episodic memory, working memory, and perceptual speed in 179 healthy adults aged 64-68 years. Previously, the T-allele of a DA D2-receptor single-nucleotide polymorphism, C957T, was associated with increased apparent affinity of C-11-raclopride, giving rise to higher BP values despite similar receptor density values between allelic groups. Consequently, we hypothesized that C-11-raclopride BP measures inflated by affinity rather than D2-receptor density in T-allele carriers would not be predictive of DA integrity and therefore prevent finding an association between C-11-raclopride BP and cognitive performance. In accordance with previous findings, we show that C-11-raclopride BP was increased in T-homozygotes. Importantly, C-11-raclopride BP was only associated with cognitive performance in groups with low or average ligand affinity (C-allele carriers of C957T, n = 124), but not in the high-affinity group (T-homozygotes, n = 55). The strongest C-11-raclopride BP-cognition associations and the highest level of performance were found in C-homozygotes. These findings show that genetic differences modulate the link between BP and cognition and thus have important implications for the interpretation of DA assessments with PET and C-11-raclopride in multiple disciplines ranging from cognitive neuroscience to psychiatry and neurology.

  • 20. Koehncke, Ylva
    et al.
    Papenberg, Goran
    Jonasson, Lars S.
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Karalija, Nina
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Salami, Alireza
    Andersson, Micael
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Bäckman, Lars
    Lindenberger, Ulman
    Lövdén, Martin
    Self-rated intensity of habitual physical activities is positively associated with dopamine D-2/3 receptor availability and cognition2018Ingår i: NeuroImage, ISSN 1053-8119, E-ISSN 1095-9572, Vol. 181, s. 605-616Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Between-person differences in cognitive performance in older age are associated with variations in physical activity. The neurotransmitter dopamine (DA) contributes to cognitive performance, and the DA system deteriorates with advancing age. Animal data and a patient study suggest that physical activity modulates DA receptor availability, but data from healthy humans are lacking. In a cross-sectional study with 178 adults aged 64-68 years, we investigated links among self-reported physical activity, D(2/3)DA receptor (D2/3DR) availability, and cognitive performance. D2/3DR availability was measured with [C-11]raclopride positron emission tomography at rest. We used structural equation modeling to obtain latent factors for processing speed, episodic memory, working memory, physical activity, and D2/3DR availability in caudate, putamen, and hippocampus. Physical activity intensity was positively associated with D2/3DR availability in caudate, but not putamen and hippocampus. Frequency of physical activity was not related to D2/3DR availability. Physical activity intensity was positively related to episodic memory and working memory. D2/3DR availability in caudate and hippocampus was positively related to episodic memory. Taken together, our results suggest that striatal DA availability might be a neurochemical correlate of episodic memory that is also associated with physical activity.

  • 21.
    Larsson, Anne
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Holmberg, Daniel
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Sundström, Torbjörn
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Optimal contrast as a function of noise for Butterworth filtering of 111 In-pentetreotide SPECT when using model-based compensation2013Ingår i: 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013Konferensbidrag (Refereegranskat)
    Abstract [en]

    In 111 In-pentetreotide SPECT, it can be difficult to detect small tumors because of low spatial resolution and high noise levels. For an efficient cancer treatment, it is however important to detect the tumors at an early stage. The aim of this study was to perform optimization of Butterworth post-filtering of In-111-pentetreotide SPECT, with regard to small tumor detection in the liver. All images were reconstructed with model-based OSEM reconstruction. Two collimators are evaluated, the extended low-energy general-purpose (ELEGP) and the medium-energy general-purpose (MEGP) collimator. The raw-data projection images are produced using Monte Carlo simulations of an anthropomorphic phantom with realistic In-111-pentetreotide uptake, including seven spherical tumors in the liver. Evaluation was performed using tumor contrast as a function of background noise. According to the results, the detection of the smallest tumors is facilitated by not applying a filter. For somewhat larger tumors, a Butterworth filter of critical frequencies of 0.5-0.6 cm(-1) and an order of 10-12 is more appropriate. ELEGP proved to be better than MEGP for small tumor detection. The study is a continuation of a previous project where collimator choice, acquisition time, number of projection angles and OSEM settings were studied for the same geometry.

  • 22.
    Larsson, Anne
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Johansson, Adam
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Nyholm, Tufve
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Asklund, Thomas
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Karlsson, Mikael
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images2013Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine, ISSN 0968-5243, E-ISSN 1352-8661, Vol. 26, nr 1, s. 127-136Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    The aim of this study was to evaluate MR-based attenuation correction of PET emission data of the head, based on a previously described technique that calculates substitute CT (sCT) images from a set of MR images. Images from eight patients, examined with F-18-FLT PET/CT and MRI, were included. sCT images were calculated and co-registered to the corresponding CT images, and transferred to the PET/CT scanner for reconstruction. The new reconstructions were then compared with the originals. The effect of replacing bone with soft tissue in the sCT-images was also evaluated. The average relative difference between the sCT-corrected PET images and the CT-corrected PET images was 1.6 % for the head and 1.9 % for the brain. The average standard deviations of the relative differences within the head were relatively high, at 13.2 %, primarily because of large differences in the nasal septa region. For the brain, the average standard deviation was lower, 4.1 %. The global average difference in the head when replacing bone with soft tissue was 11 %. The method presented here has a high rate of accuracy, but high-precision quantitative imaging of the nasal septa region is not possible at the moment.

  • 23.
    Leffler, Klara
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för matematik och matematisk statistik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Häggström, Ida
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Yu, Jun
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för matematik och matematisk statistik.
    Sharper Positron Emission Tomography: Intelligent Data Sampling to Promote Accelerated Medical Imaging2019Konferensbidrag (Övrigt vetenskapligt)
  • 24.
    Lizana, Helena
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Johansson, L.
    Umeå universitet.
    Larsson, A.
    Umeå universitet.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Linder, J.
    Umeå universitet.
    Ögren, M.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Varrone, A.
    Halldin, C.
    Jakobson Mo, Susanna
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Dosimetry and whole body distribution of [F-18]PE2I in healthy volunteers2016Ingår i: European Journal of Nuclear Medicine and Molecular Imaging, ISSN 1619-7070, E-ISSN 1619-7089, Vol. 43, s. S533-S533Artikel i tidskrift (Refereegranskat)
  • 25.
    Lizana, Helena
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Johansson, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Ögren, Mattias
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Linder, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Halldin, Christer
    Varrone, Andrea
    Jakobson Mo, Susanna
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Whole-Body Biodistribution and Dosimetry of the Dopamine Transporter Radioligand 18F-FE-PE2I in Human Subjects2018Ingår i: Journal of Nuclear Medicine, ISSN 0161-5505, E-ISSN 1535-5667, Vol. 59, nr 8, s. 1275-1280Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    F-18-(E)-N-(3-iodoprop-2-enyl)-2 beta-carbofluoroethoxy-3 beta-(4'-methylphenyl) nortropane (F-18-FE-PE2I) was recently developed and has shown adequate affinity and high selectivity for the dopamine transporter (DAT). Previous studies have shown promising results for F-18-FE-PE2I as a suitable radioligand for DAT imaging. In this study, we investigated the whole-body biodistribution and dosimetry of F-18-FE-PE2I in healthy volunteers to support its utility as a suitable PET imaging agent for the DAT. Methods: Five healthy volunteers were given a mean activity of 2.5 MBq/kg, and 3 PET scans, head to thigh, were performed immediately after injection followed by 4 whole-body PET/CT scans between 0.5 and 6 h after injection. Blood samples were drawn in connection with the whole-body scans, and all urine was collected until 6 h after injection. Volumes of interest were delineated around 17 organs on all images, and the areas under the time-activity curves were calculated to obtain the total number of decays in the organs. The absorbed doses to organs and the effective dose were calculated using the software IDAC. Results: The highest activity concentration was observed in the liver (0.9%-1.2% injected activity/100 g) up to 30 min after injection. At later time points, the highest concentration was seen in the gallbladder (1.1%-0.1% injected activity/100 g). The activity excreted with urine ranged between 23% and 34%, with a mean of 28%. The urinary bladder received the highest absorbed dose (119 mu Gy/MBq), followed by the liver (46 mu Gy/MBq). The effective dose was 23 mu Sv/MBq (range, 19-28 mu Sv/MBq), resulting in an effective dose of 4.6 mSv for an administered activity of 200 MBq. Conclusion: The effective dose is within the same order of magnitude as other commonly used PET imaging agents as well as DAT agents. The reasonable effective dose, together with the previously reported favorable characteristics for DAT imaging and quantification, indicates that F-18-FE-PE2I is a suitable radioligand for DAT imaging.

  • 26.
    Lundman, Josef A.
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Johansson, Adam
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States.
    Olofsson, Jörgen
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Nyholm, Tufve
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Medical Radiation Physics, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden.
    Effect of gradient field nonlinearity distortions in MRI-based attenuation maps for PET reconstruction2017Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 35, s. 1-6Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Purpose: Attenuation correction is a requirement for quantification of the activity distribution in PET. The need to base attenuation correction on MRI instead of CT has arisen with the introduction of integrated PET/MRI systems. The aim was to describe the effect of residual gradient field nonlinearity distortions on PET attenuation correction.

    Methods: MRI distortions caused by gradient field nonlinearity were simulated in CT images used for attenuation correction in PET reconstructions. The simulations yielded radial distortion of up to  at 15 cm from the scanner isocentre for distortion corrected images. The mean radial distortion of uncorrected images were 6.3 mm at the same distance. Reconstructions of PET data were performed using the distortion corrected images as well as the images where no correction had been applied.

    Results: The mean relative difference in reconstructed PET uptake intensity due to incomplete distortion correction was less than ±5%. The magnitude of this difference varied between patients and the size of the distortions remaining after distortion correction.

    Conclusions: Radial distortions of 2 mm at 15 cm radius from the scanner isocentre lead to PET attenuation correction errors smaller than 5%. Keeping the gradient field nonlinearity distortions below this limit can be a reasonable goal for MRI systems used for attenuation correction in PET for quantification purposes. A higher geometrical accuracy may, however, be warranted for quantification of peripheral lesions. These distortions can, e.g., be controlled at acceptance testing and subsequent quality assurance intervals.

  • 27. Lövdén, Martin
    et al.
    Karalija, Nina
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Andersson, Micael
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Köhncke, Ylva
    Jonasson, Lars S.
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR).
    Rieckmann, Anna
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Papenberg, Goran
    Garrett, Douglas D.
    Guitart-Masip, Marc
    Salami, Alireza
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Bäckman, Lars
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Lindenberger, Ulman
    Latent-profile analysis reveals behavioral and brain correlates of dopamine-cognition associations2018Ingår i: Cerebral Cortex, ISSN 1047-3211, E-ISSN 1460-2199, Vol. 28, nr 11, s. 3894-3907Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Evidence suggests that associations between the neurotransmitter dopamine and cognition are nonmonotonic and open to modulation by various other factors. The functional implications of a given level of dopamine may therefore differ from person to person. By applying latent-profile analysis to a large (n = 181) sample of adults aged 64-68 years, we probabilistically identified 3 subgroups that explain the multivariate associations between dopamine D2/3R availability (probed with C-11-raclopride-PET, in cortical, striatal, and hippocampal regions) and cognitive performance (episodic memory, working memory, and perceptual speed). Generally, greater receptor availability was associated with better cognitive performance. However, we discovered a subgroup of individuals for which high availability, particularly in striatum, was associated with poor performance, especially for working memory. Relative to the rest of the sample, this subgroup also had lower education, higher body-mass index, and lower resting-state connectivity between caudate nucleus and dorsolateral prefrontal cortex. We conclude that a smaller subset of individuals induces a multivariate non-linear association between dopamine D2/3R availability and cognitive performance in this group of older adults, and discuss potential reasons for these differences that await further empirical scrutiny.

  • 28.
    Mähler, Emma
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Sundström, Torbjörn
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Detecting small liver tumors with In-111-Pentetreotide SPECT-A Collimator study based on Monte Carlo simulations2012Ingår i: IEEE Transactions on Nuclear Science, ISSN 0018-9499, E-ISSN 1558-1578, Vol. 59, nr 1, s. 47-53Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    In In-111- pentetreotide single-photon emission computed tomography (SPECT), the tumor-to-background-uptake ratio is generally high. The noise is, however, also usually on a high level, and in combination with the low spatial resolution of SPECT, this may lead to difficulties in the detection of small tumors. This is especially the case in regions with a relatively high background activity, such as in the liver, which is a common region for somatostatin-positive metastases. Visually detecting the small tumors is important for a successful treatment of the cancer disease. In this paper, we compare three different parallel-hole collimators for In-111-pentetreotide SPECT regarding contrast as a function of image noise for a phantom simulating small tumors in liver background. The corresponding contrast-to-noise ratios are also presented. All raw-data projections are produced using Monte Carlo simulations. The collimators are of type low-energy general-purpose (LEGP), extended LEGP (ELEGP), and medium-energy general-purpose (MEGP). Reconstructions were performed with OSEM both with and without model-based compensation. Of the investigated collimators, the ELEGP collimator proved to be the most optimal for the smallest tumors, both with and without model-based compensation included in the reconstruction. It is also shown that model-based compensation outperforms the conventional reconstruction technique.

  • 29.
    Nevalainen, Nina
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Andersson, Micael
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB), Fysiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Ögren, Mattias
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Lövdén, M
    Aging Research Center, Karolinska Institutet & Stockholm University, Stockholm.
    Lindenberger, U
    Center for Lifespan Psychology, Max Planck Institute for Human Development, Berlin, Germany.
    Bäckman, L
    Aging Research Center, Karolinska Institutet & Stockholm University, Stockholm.
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB), Fysiologi. Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    COBRA: A prospective multimodal imaging study of dopamine, brain structure and function, and cognition.2015Ingår i: Brain Research, ISSN 0006-8993, E-ISSN 1872-6240, Vol. 1612, s. 83-103Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Cognitive decline is a characteristic feature of normal human aging. Previous work has demonstrated marked interindividual variability in onset and rate of decline. Such variability has been linked to factors such as maintenance of functional and structural brain integrity, genetics, and lifestyle. Still, few, if any, studies have combined a longitudinal design with repeated multimodal imaging and a comprehensive assessment of cognition as well as genetic and lifestyle factors. The present paper introduces the Cognition, Brain, and Aging (COBRA) study, in which cognitive performance and brain structure and function are measured in a cohort of 181 older adults aged 64 to 68 years at baseline. Participants will be followed longitudinally over a 10-year period, resulting in a total of three equally spaced measurement occasions. The measurement protocol at each occasion comprises a comprehensive set of behavioral and imaging measures. Cognitive performance is evaluated via computerized testing of working memory, episodic memory, perceptual speed, motor speed, implicit sequence learning, and vocabulary. Brain imaging is performed using positron emission tomography with [(11)C]-raclopride to assess dopamine D2/D3 receptor availability. Structural magnetic resonance imaging (MRI) is used for assessment of white and gray-matter integrity and cerebrovascular perfusion, and functional MRI maps brain activation during rest and active task conditions. Lifestyle descriptives are collected, and blood samples are obtained and stored for future evaluation. Here, we present selected results from the baseline assessment along with a discussion of sample characteristics and methodological considerations that determined the design of the study.

  • 30.
    Nyberg, Lars
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Karalija, Nina
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Salami, Alireza
    Andersson, Micael
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Kaboovand, Neda
    Köhncke, Ylva
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Rieckmann, Anna
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Papenberg, Goran
    Garrett, Douglas D.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Lövdén, Martin
    Lindenberger, Ulman
    Bäckman, Lars
    Dopamine D2 receptor availability is linked to hippocampal-caudate functional connectivity and episodic memory2016Ingår i: Proceedings of the National Academy of Sciences of the United States of America, ISSN 0027-8424, E-ISSN 1091-6490, Vol. 113, nr 28, s. 7918-7923Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    D1 and D2 dopamine receptors (D1DRs and D2DRs) may contribute differently to various aspects of memory and cognition. The D1DR system has been linked to functions supported by the prefrontal cortex. By contrast, the role of the D2DR system is less clear, although it has been hypothesized that D2DRs make a specific contribution to hippocampus-based cognitive functions. Here we present results from 181 healthy adults between 64 and 68 y of age who underwent comprehensive assessment of episodic memory, working memory, and processing speed, along with MRI and D2DR assessment with [C-11]raclopride and PET. Caudate D2DR availability was positively associated with episodic memory but not with working memory or speed. Whole-brain analyses further revealed a relation between hippocampal D2DR availability and episodic memory. Hippocampal and caudate D2DR availability were interrelated, and functional MRI-based resting-state functional connectivity between the ventral caudate and medial temporal cortex increased as a function of caudate D2DR availability. Collectively, these findings indicate that D2DRs make a specific contribution to hippocampus-based cognition by influencing striatal and hippocampal regions, and their interactions.

  • 31. Papenberg, Goran
    et al.
    Karalija, Nina
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Salami, Alireza
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Andersson, Micael
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Lindenberger, Ulman
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Bäckman, Lars
    The Influence of Hippocampal Dopamine D2 Receptors on Episodic Memory Is Modulated by BDNF and KIBRA Polymorphisms2019Ingår i: Journal of cognitive neuroscience, ISSN 0898-929X, E-ISSN 1530-8898, Vol. 31, nr 9, s. 1422-1429Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Episodic memory is a polygenic trait influenced by different molecular mechanisms. We used PET and a candidate gene approach to investigate how individual differences at the molecular level translate into between-person differences in episodic memory performance of elderly persons. Specifically, we examined the interactive effects between hippocampal dopamine D2 receptor (D2DR) availability and candidate genes relevant for hippocampus-related memory functioning. We show that the positive effects of high D2DR availability in the hippocampus on episodic memory are confined to carriers of advantageous genotypes of the brain-derived neurotrophic factor (BDNF, rs6265) and the kidney and brain expressed protein (KIBRA, rs17070145) polymorphisms. By contrast, these polymorphisms did not modulate the positive relationship between caudate D2DR availability and episodic memory.

  • 32.
    Rutegård, Miriam
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Båtsman, Malin
    Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Patologi.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Brynolfsson, Patrik
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Brännström, Fredrik
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Rutegård, Jörgen
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Ljuslinder, Ingrid
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Blomqvist, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Palmqvist, Richard
    Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Patologi.
    Rutegård, Martin
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    PET/MRI and PET/CT hybrid imaging of rectal cancer - description and initial observations from the RECTOPET (REctal Cancer trial on PET/MRI/CT) study2019Ingår i: Cancer Imaging, ISSN 1740-5025, E-ISSN 1470-7330, Vol. 19, artikel-id 52Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    PurposeThe role of hybrid imaging using F-18-fluoro-2-deoxy-D-glucose positron-emission tomography (FDG-PET), computed tomography (CT) and magnetic resonance imaging (MRI) to improve preoperative evaluation of rectal cancer is largely unknown. To investigate this, the RECTOPET (REctal Cancer Trial on PET/MRI/CT) study has been launched with the aim to assess staging and restaging of primary rectal cancer. This report presents the study workflow and the initial experiences of the impact of PET/CT on staging and management of the first patients included in the RECTOPET study.MethodsThis prospective cohort study, initiated in September 2016, is actively recruiting patients from Region Vasterbotten in Sweden. This pilot study includes patients recruited and followed up until December 2017. All patients had a biopsy-verified rectal adenocarcinoma and underwent a minimum of one preoperative FDG-PET/CT and FDG-PET/MRI examination. These patients were referred to the colorectal cancer multidisciplinary team meeting at Umea University Hospital. All available data were evaluated when making management recommendations. The clinical course was noted and changes consequent to PET imaging were described; surgical specimens underwent dedicated MRI for anatomical matching between imaging and histopathology.ResultsTwenty-four patients have so far been included in the study. Four patients were deemed unresectable, while 19 patients underwent or were scheduled for surgery; one patient was enrolled in a watch-and-wait programme after restaging. Consequent to taking part in the study, two patients were upstaged to M1 disease: one patient was diagnosed with a solitary hepatic metastasis detected using PET/CT and underwent metastasectomy prior to rectal cancer surgery, while one patient with a small, but metabolically active, lung nodulus experienced no change of management. PET/MRI did not contribute to any recorded change in patient management.ConclusionsThe RECTOPET study investigating the role of PET/CT and PET/MRI for preoperative staging of primary rectal cancer patients will provide novel data that clarify the value of adding hybrid to conventional imaging, and the role of PET/CT versus PET/MRI.Trial registrationNCT03846882.

  • 33.
    Salami, Alireza
    et al.
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Wallenberg centrum för molekylär medicin vid Umeå universitet (WCMM). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Aging Research Center, Karolinska Institutet and Stockholm University, Sweden.
    Garrett, Douglas D.
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Rieckmann, Anna
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Papenberg, Goran
    Karalija, Nina
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Center for Lifespan Psychology, Max Planck Institute for Human Development, Berlin, Germany.
    Jonasson, Lars
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
    Andersson, Micael
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Johansson, Jarkko
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Lövdén, Martin
    Lindenberger, Ulman
    Bäckman, Lars
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Dopamine D2/3 Binding Potential Modulates Neural Signatures of Working Memory in a Load-Dependent Fashion.2019Ingår i: Journal of Neuroscience, ISSN 0270-6474, E-ISSN 1529-2401, Vol. 39, nr 3, s. 537-547Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Dopamine (DA) modulates corticostriatal connections. Studies in which imaging of the DA system is integrated with functional imaging during cognitive performance have yielded mixed findings. Some work has shown a link between striatal DA (measured by PET) and fMRI activations, whereas others have failed to observe such a relationship. One possible reason for these discrepant findings is differences in task demands, such that a more demanding task with greater prefrontal activations may yield a stronger association with DA. Moreover, a potential DA–BOLD association may be modulated by task performance. We studied 155 (104 normal-performing and 51 low-performing) healthy older adults (43% females) who underwent fMRI scanning while performing a working memory (WM) n-back task along with DA D2/3 PET assessment using [11C]raclopride. Using multivariate partial-least-squares analysis, we observed a significant pattern revealing positive associations of striatal as well as extrastriatal DA D2/3 receptors to BOLD response in the thalamo–striatal–cortical circuit, which supports WM functioning. Critically, the DA–BOLD association in normal-performing, but not low-performing, individuals was expressed in a load-dependent fashion, with stronger associations during 3-back than 1-/2-back conditions. Moreover, normal-performing adults expressing upregulated BOLD in response to increasing task demands showed a stronger DA–BOLD association during 3-back, whereas low-performing individuals expressed a stronger association during 2-back conditions. This pattern suggests a nonlinear DA–BOLD performance association, with the strongest link at the maximum capacity level. Together, our results suggest that DA may have a stronger impact on functional brain responses during more demanding cognitive tasks.

  • 34.
    Sandgren, Kristina
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Johansson, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Jonsson, Joakim
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Ögren, Mattias
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Ögren, Margareta
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Andersson, Martin
    Strandberg, Sara
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Nyholm, Tufve
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Widmark, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Radiation dosimetry of [Ga-68]PSMA-11 in low-risk prostate cancer patients2019Ingår i: EJNMMI Physics, ISSN 2197-7364, E-ISSN 2191-219X, Vol. 6, artikel-id 2Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Background: 68Ga-labeled Glu-NH-CO-NH-Lys(Ahx)-HBED-CC ([68Ga]PSMA-11) has been increasingly used to image prostate cancer using positron emission tomography (PET)/computed tomography (CT) both during diagnosis and treatment planning. It has been shown to be of clinical value for patients both in the primary and secondary stages of prostate cancer. The aim of this study was to determine the effective dose and organ doses from injection of [68Ga]PSMA-11 in a cohort of low-risk prostate cancer patients.

    Methods: Six low-risk prostate cancer patients were injected with 133–178 MBq [68Ga]PSMA-11 and examined with four PET/CT acquisitions from injection to 255 min post-injection. Urine was collected up to 4 h post-injection, and venous blood samples were drawn at 45 min, 85 min, 175 min, and 245 min post-injection. Kidneys, liver, lungs, spleen, salivary and lacrimal glands, and total body where delineated, and cumulated activities and absorbed organ doses calculated. The software IDAC-Dose 2.1 was used to calculate absorbed organ doses according to the International Commission on Radiological Protection (ICRP) publication 107 using specific absorbed fractions published in ICRP 133 and effective dose according to ICRP Publication 103. We also estimated the absorbed dose to the eye lenses using Monte Carlo methods.

    Results: [68Ga]PSMA-11 was rapidly cleared from the blood and accumulated preferentially in the kidneys and the liver. The substance has a biological half-life in blood of 6.5 min (91%) and 4.4 h (9%). The effective dose was calculated to 0.022 mSv/MBq. The kidneys received approximately 40 mGy after an injection with 160 MBq [68Ga]PSMA-11 while the lacrimal glands obtained an absorbed dose of 0.12 mGy per administered MBq. Regarding the eye lenses, the absorbed dose was low (0.0051 mGy/MBq).

    Conclusion: The effective dose for [68Ga]PSMA-11 is 0.022 mSv/MBq, where the kidneys and lacrimal glands receiving the highest organ dose.

  • 35.
    Sandgren, Kristina
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Jonsson, Joakim
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Nyholm, Tufve
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Strandberg, Sara
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Ögren, M.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Blomqvist, Lennart
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Friedrich, Bengt
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Urologi och andrologi.
    Bergh, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap.
    Ahlström Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Windmark, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Histology correlation of in vivo [68Ga]PSMA-PET/MRI data of the prostate2018Ingår i: Radiotherapy and Oncology, ISSN 0167-8140, E-ISSN 1879-0887, Vol. 127, s. S541-S541Artikel i tidskrift (Övrigt vetenskapligt)
  • 36.
    Strandberg, Sara
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Hashemi, Armin
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Optimization of PET reconstruction algorithm, SUV thresholding algorithm and PET acquisition time in clinical 11C-acetate PET/CT2018Ingår i: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 13, nr 12, artikel-id e0209169Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Introduction 11C-acetate (ACE)-PET/CT is used for staging of high-risk prostate cancer. PET data is reconstructed with iterative algorithms, such as VUEPointHD ViP (VPHD) and VUEPoint HD Sharp IR (SharpIR), the latter with additional resolution recovery. It is expected that the resolution recovery algorithm should render more accurate maximum and mean standardized uptake values (SUVmax and SUVmean) and functional tumor volumes (FTV) than the ordinary OSEM. Performing quantitative analysis, choice of volume-of-interest delineation algorithm (SUV threshold) may influence FTV. Optimizing PET acquisition time is justified if image quality and quantitation do not deteriorate. The aim of this study is to identify the optimal reconstruction algorithm, SUV threshold and acquisition time for ACE-PET/CT. Methods ACE-PET/CT data acquired with a General Electric Discovery 690 PET/CT from 16 consecutive high-risk prostate cancer patients was reconstructed with VPHD and SharpIR. Forty pelvic lymph nodes (LNs) and 14 prostate glands were delineated with 42% and estimated threshold. SUVmax, SUVmean, FTV and total lesion uptake were measured. Default acquisition time was four minutes per bed position. In a subset of lesions, acquisition times of one, two and four minutes were evaluated. Structural tumor volumes (STV) of the LNs were measured with CT for correlation with functional volumetric parameters. To validate SUV quantification under different conditions with SharpIR 42%, recovery coefficients (RCs) of SUVmean and FTV were calculated from a phantom with 18F-fluoro-deoxy-glucose (FDG)-filled volumes 0.1–9.2cm3 and signal-to-background (S/B) ratios 4.3–15.9. Results With SharpIR, SUVmax and SUVmean were higher and FTV lower compared with VPHD, regardless of threshold method, in both prostates and LNs. Total lesion uptake determined with both threshold methods was lower with SharpIR compared with VPHD with both threshold methods, except in subgroup analysis of prostate targets where estimated threshold returned higher values. Longer acquisition times returned higher FTV for both threshold methods, regardless of reconstruction algorithm. The FTV difference was most pronounced with one minute’s acquisition per bed position, which also produced visually the highest noise. SUV parameters were unaffected by varying acquisition times. FTV with SharpIR 42% showed the best correspondence with STV. SharpIR 42% gave higher RCs of SUVmean and FTV with increasing phantom size and S/B-ratio, as expected. Conclusions Delineation with SharpIR 42% seems to provide the most accurate combined information from SUVmax, SUVmean, FTV and total lesion uptake. Acquisition time may be shortened to two minutes per bed position with preserved image quality.

  • 37.
    Strandberg, Sara
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Karlsson, Camilla Thellenberg
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Sundström, Torbjörn
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Ögren, Mattias
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Ögren, Margareta
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    11C-acetate PET/CT in pre-therapeutic lymph node staging in high-risk prostate cancer patients and its influence on disease management: a retrospective study2014Ingår i: EJNMMI Research, ISSN 2191-219X, E-ISSN 2191-219X, Vol. 4, nr 55, s. 1-9Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Background: Radiation treatment with simultaneous integrated boost against suspected lymph node metastases may be a curative therapeutic option in patients with high-risk prostate cancer (> 15% estimated risk of pelvic lymph node metastases according to the Cagiannos nomogram). C-11-acetate positron emission tomography/computed tomography (PET/CT) can be used for primary staging as well as for detection of suspected relapse of prostate cancer. The aims of this study were to evaluate the association between positive C-11-acetate PET/CT findings and the estimated risk of pelvic lymph node metastases and to assess the impact of C-11-acetate PET/CT on patient management in high-risk prostate cancer patients. Methods: Fifty consecutive prostate cancer patients referred for primary staging with C-11-acetate PET/CT prior to radiotherapy with curative intention were enrolled in this retrospective study. Results: All patients showed increased C-11-acetate uptake in the prostate. Pelvic lymph node uptake was seen in 42% (21/50) of the patients, with positive external iliac lymph nodes in 71% (15/21) of these. The overall observed proportion of PET/CT-positive pelvic lymph nodes at patient level was higher than the average estimated risk, especially in low-risk groups (< 15%). There was a significant association between observed proportion and estimated risk of pelvic lymph node metastases in groups with <= 45 and >45% estimated risk. Treatment strategy was altered due to C-11-acetate PET/CT findings in 43% (20/47) of the patients. Conclusions: The observed proportion of C-11-acetate PET/CT findings suggestive of locoregional metastases was higher than the estimated risk, suggesting that the Cagiannos nomogram underestimates the risk for metastases. The imaging results with C-11-acetate PET/CT have a considerable impact on patient management.

  • 38.
    Strandberg, Sara
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Karlsson, Camilla Thellenberg
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Ögren, Mattias
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    C-11-Acetate-PET/CT Compared to Tc-99m-HDP Bone Scintigraphy in Primary Staging of High-risk Prostate Cancer2016Ingår i: Anticancer Research, ISSN 0250-7005, E-ISSN 1791-7530, Vol. 36, nr 12, s. 6475-6479Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Aim: The aim of this study was to evaluate the detection rate of bone metastases and the added value of C-11-acetate (ACE) positron-emission tomography/computed tomography (PET/CT) compared to bone scintigraphy (BS) in high-risk prostate cancer (PC). Materials and Methods: A total of 66 untreated patients with high-risk PC with ACE-PET/CT and planar BS findings within 3 months of each other were retrospectively enrolled. Findings were compared and verified with follow-up data after an average of 26 months. Results: The rate of detection of bone metastases was superior with ACE-PET/CT compared to BS (p<0.01). Agreement between the methods and between BS and follow-up was moderate (Cohen's kappa coefficient of 0.64 and 0.66, respectively). Agreement between ACE-PET/CT and follow-up was excellent (kappa coefficient of 0.95). Therapy was changed in 11% of patients due to ACE-PET/CT results. Conclusion: ACE-PET/CT performed better than planar BS in detection of bone metastases in high-risk PC. ACE-PET/CT findings influenced clinical management.

  • 39.
    Wallstén, Elin
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Karlsson, Mikael
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    A Study of Dynamic PET Frame-Binning on the Reference Logan Binding Potential2017Ingår i: IEEE Transactions on Radiation and Plasma Medical Sciences, ISSN 2469-7311, Vol. 1, nr 2, s. 128-135Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    Objective: The reference Logan plot is a tool for determining the non-displaceable binding potential for dynamic PET exams using tracers with reversible bindings. Dynamic frame protocols affect noise in PET images and short frames can lead to quantitative uncertainties and noise-induced reconstruction bias. The aim of this study was to analyze the effect of frame binning on 11C-Raclopride striatal binding potential from reference Logan analysis. Methods: 12 healthy volunteers were scanned in list mode using 11C-raclopride, and the image data were reconstructed into 9 different frame binning schemes whereof 3 clinical schemes. Reconstruction was performed with 3 different algorithms, one based on filtered back projection (FBP) and two based on ordered subset expectation maximization (OSEM); one including resolution recovery. Logan plots were used for calculating the non-displaceable binding potential. Variation in binding potential was evaluated using Students t-tests. Results: It was found that frame lengths of up to 60 s gave significantly different results compared to the reference clinical protocol for OSEM, both with and without resolution recovery (maximum deviation: 10.3 % for the 15 s protocol). For FBP, frame lengths of up to 30 s gave significantly different results with a maximum deviation of 2.8 %. The higher sampling dependence of OSEM compared to FBP is likely due to noise-dependent bias in the OSEM algorithm, most apparent at high noise levels. Conclusions: Bias related to OSEM reconstruction of high-noise data is an important factor for dynamic PET protocols. Time frames of 120 s or more generate the most stable values for the striatum binding potential with the reference Logan plot for 11C-Raclopride brain PET.

  • 40.
    Wallstén, Elin
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Karlsson, Mikael
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Nyberg, Lars
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Häggström, I.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    The Influence of Time Sampling on Parameters in the Logan Plot2013Ingår i: 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013Konferensbidrag (Refereegranskat)
    Abstract [en]

    The Logan plot is a graphical method for reversible tracer bindings. The bias and uncertainties of this method have previously been analyzed with respect to noise, but little is known about the direct effects from varying the time sampling scheme. This study aims to investigate the effect of time sampling on the binding potential from the reference Logan plot. Image data from seven healthy subjects imaged with [11C]raclopride was reconstructed into six dynamic series of equal length time frames with frame times between 15 s and 480 s. Images were reconstructed using both filtered back projection (FBP) and a resolution enhanced ordered subset expectation maximization (OSEM) algorithm, SharpIR. For each sampling scheme, the nondisplaceable binding potential (BPND) parameter was calculated from the reference Logan plot with cerebellum as a reference region. The variation in BPND was analyzed as percentage deviations from the BPND for the 480 s scheme. R-2 of the linear fit was also analyzed. Comparison between all sampling schemes showed that the largest deviation in BPND was 7.4% between the 15 s sampling scheme and the 480 s sampling scheme reconstructed with SharpIR. The corresponding deviation for FBP images was 1.6%. R-2 was highest for long time frames, but all R-2 values were above 0.997 in this study.

  • 41.
    Wallstén, Elin
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Axelsson, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Sundström, Torbjörn
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Riklund, Katrine
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Larsson, Anne
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Subcentimeter Tumor Lesion Delineation for High-Resolution 18F-FDG PET Images: Optimizing Correction for Partial-Volume Effects.2013Ingår i: Journal of Nuclear Medicine Technology, ISSN 0091-4916, E-ISSN 1535-5675, Vol. 41, nr 2, s. 85-91Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    In PET, partial-volume effects cause errors in estimation of size and activity for small objects with radiopharmaceutical uptake. Recent methods for image reconstruction, compared with traditional reconstruction techniques, include algorithms for resolution recovery that result in images with higher resolution and enable quantification of size and activity of smaller objects. The purpose of this study was to evaluate a combination of 2 algorithms for volume delineation and partial-volume correction on uptake volumes smaller than 0.7 mL using image reconstruction algorithms with and without resolution recovery.

    METHODS: Volumes of interests (VOIs) were delineated using a threshold intensity calculated as a weighted sum of tumor and background intensities. These VOIs were used for calculating correction factors by convolving a tumor mask with the system point-spread function. The methods algorithms were evaluated using a phantom constructed from 5 small different-sized balloons filled with (18)F-FDG in background activity. Six different backgrounds were used. Data were acquired using a PET/CT scanner, and the images were reconstructed using 2 iterative algorithms, one of which used a resolution recovery algorithm.

    RESULTS: For the images reconstructed using the resolution recovery algorithm, the method for volume delineation resulted in VOI sizes that were correct within 1 SD for all balloons of a volume of 0.35 mL (equivalent diameter, 8.8 mm) and larger, in all backgrounds. For the images reconstructed without resolution recovery, the VOI sizes were background-dependent and generally less accurate. Correct volume delineations generally led to accurate activity estimates.

    CONCLUSION: The algorithms tested on the phantom developed for this study could, for this PET camera and these reconstruction algorithms, be used for accurate volume delineation and activity quantification of lesions 0.35 mL and larger.

1 - 41 av 41
RefereraExporteraLänk till träfflistan
Permanent länk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf