umu.sePublications
Change search
Refine search result
1 - 1 of 1
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1. Stark, Birgit
    et al.
    Emanuelsson, Peter
    Gunnarsson, Ulf
    Department of Surgery, CLINTEC, Karolinska Institute, Stockholm , Sweden.
    Strigård, Karin
    Department of Surgery, CLINTEC, Karolinska Institute, Stockholm , Sweden.
    Validation of Biodex system 4 for measuring the strength of muscles in patients with rectus diastasis2012In: Journal of Plastic Surgery and Hand Surgery, ISSN 2000-656X, E-ISSN 2000-6764, Vol. 46, no 2, p. 102-105Article in journal (Refereed)
    Abstract [en]

    To investigate the validity and reliability of the Biodex system 4 in the assessment of abdominal strength in patients with rectus diastasis, we studied 10 healthy volunteers and 10 patients with rectus diastasis of more than 3 cm. We assessed test-retest reliability at 30(o) and 60(o) of extension/flexion spinal angles, respectively, and isometric muscle strength with and without the abdominal girdle. Reliability was calculated using the interclass correlation coefficient (ICC). Validity was evaluated by correlation with the International Physical Activity Questionnaire (IPAQ) and a visual analogue scale (VAS) for self-assessment of abdominal muscular strength. The Kendall-Tau and Spearman tests were used. Reliability was excellent with ICC values ranging between 0.77 and 0.97. There was no significant difference in muscular strength for tests with or without a girdle except with 60(o) extension. The internal validity assessed as the correlation between VAS and isometric strength (p = 0.008) was excellent, whereas there was no correlation with IPAQ. The Biodex system 4 is a valuable and reliable instrument to measure abdominal wall strength in patients with rectus diastasis. The internal validity is excellent. The incongruence between abdominal muscle strength, as measured using the Biodex system 4, and IPAQ indicates that there is no relation between general physical activity (IPAQ) and muscular strength in patients with rectus diastasis.

1 - 1 of 1
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf