umu.sePublikasjoner
Endre søk
Begrens søket
123 1 - 50 of 121
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Alrifaiy, Ahmed
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Luleå University of Technology.
    Bitaraf, Nazanin
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Luleå University of Technology.
    Druzin, Michael
    Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB), Fysiologi.
    Lindahl, Olof
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Luleå University of Technology.
    Ramser, K
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Luleå University of Technology.
    Hypoxia on a chip: a novel approach for patch-clamp studies in a microfluidic system with full oxygen control2013Inngår i: World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China / [ed] Mian Long, Springer Berlin/Heidelberg, 2013, 313-316 s.Konferansepaper (Fagfellevurdert)
    Abstract [en]

    A new approach to perform patch-clamp experiments on living cells under controlled anoxic and normoxic conditions was developed and tested. To provide an optimal control over the oxygen content and the biochemical environment a patch-clamp recording micropipette was integrated within an oxygen tight poly-methyl methacrylate (PMMA) based microchip. The oxygen content within the microfluidic chamber surrounding patch-clamp micropipette was maintained at 0.5-1.5 % by a continuous flow of artificial extracellular solution purged with nitrogen. The nerve and glial cells acutely obtained from the male rat brain were trapped by the optical tweezers and steered towards the patch-clamp micropipette through the channels of the microchip in order to achieve a close contact between the pipette and the cellular membrane. The patch-clamp recordings revealed that optical tweezers did not affect the electrophysiological properties of the tested cells suggesting that optical trapping is a safe and non-traumatizing method to manipulate living cells in the microfluidic system. Thus, our approach of combining optical tweezers and a gas-tight microfluidic chamber may be applied in various electrophysiological investigations of single cells were optimal control of the experimental conditions and the sample in a closed environment are necessary.

  • 2.
    Alrifaiy, Ahmed
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Ramser, Kerstin
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    How to integrate a micropipette into a closed microfluidic system: absorption spectra of an optically trapped erythrocyte2011Inngår i: Biomedical Optics Express, ISSN 2156-7085, E-ISSN 2156-7085, Vol. 2, nr 8, 2299-2306 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    We present a new concept of integrating a micropipette within a closed microfluidic system equipped with optical tweezers and a UV-Vis spectrometer. A single red blood cell (RBC) was optically trapped and steered in three dimensions towards a micropipette that was integrated in the microfluidic system. Different oxygenation states of the RBC, triggered by altering the oxygen content in the microchannels through a pump system, were optically monitored by a UV-Vis spectrometer. The built setup is aimed to act as a multifunctional system where the biochemical content and the electrophysiological reaction of a single cell can be monitored simultaneously. The system can be used for other applications like single cell sorting, in vitro fertilization or electrophysiological experiments with precise environmental control of the gas-, and chemical content. 

  • 3.
    Ambarki, Khalid
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Lindqvist, Tomas
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Petterson, E
    Warntjes, JBM
    Birgander, Richard
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Evaluation of automatic measurement of the intracranial volume based on quantitative MR imaging2012Inngår i: American Journal of Neuroradiology, ISSN 0195-6108, E-ISSN 1936-959X, Vol. 33, nr 10, 1951-1956 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    BACKGROUND AND PURPOSE: Brain size is commonly described in relation to ICV, whereby accurate assessment of this quantity is fundamental. Recently, an optimized MR sequence (QRAPMASTER) was developed for simultaneous quantification of T1, T2, and proton density. ICV can be measured automatically within minutes from QRAPMASTER outputs and a dedicated software, SyMRI. Automatic estimations of ICV were evaluated against the manual segmentation.

    MATERIALS AND METHODS: In 19 healthy subjects, manual segmentation of ICV was performed by 2 neuroradiologists (Obs1, Obs2) by using QBrain software and conventional T2-weighted images. The automatic segmentation from the QRAPMASTER output was performed by using SyMRI. Manual corrections of the automatic segmentation were performed (corrected-automatic) by Obs1 and Obs2, who were blinded from each other. Finally, the repeatability of the automatic method was evaluated in 6 additional healthy subjects, each having 6 repeated QRAPMASTER scans. The time required to measure ICV was recorded.

    RESULTS: No significant difference was found between reference and automatic (and corrected-automatic) ICV (P > .25). The mean difference between the reference and automatic measurement was -4.84 ± 19.57 mL (or 0.31 ± 1.35%). Mean differences between the reference and the corrected-automatic measurements were -0.47 ± 17.95 mL (-0.01 ± 1.24%) and -1.26 ± 17.68 mL (-0.06 ± 1.22%) for Obs1 and Obs2, respectively. The repeatability errors of the automatic and the corrected-automatic method were <1%. The automatic method required 1 minute 11 seconds (SD = 12 seconds) of processing. Adding manual corrections required another 1 minute 32 seconds (SD = 38 seconds).

    CONCLUSIONS: Automatic and corrected-automatic quantification of ICV showed good agreement with the reference method. SyMRI software provided a fast and reproducible measure of ICV.

  • 4.
    Ambarki, Khalid
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Petr, J.
    Wahlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Wirestam, R.
    Zarrinkoob, Laleh
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Partial Volume Correction of Cerebral Perfusion Estimates Obtained by Arterial Spin Labeling2015Inngår i: 16th Nordic-Baltic Conference on Biomedical Engineering: 16. NBC & 10. MTD 2014 joint conferences. October 14-16, 2014, Gothenburg, Sweden, 2015, Vol. 48, 17-19 s.Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Arterial Spin labeling (ASL) is a fully non-invasive MRI method capable to quantify cerebral perfusion. However, gray (GM) and white matter (WM) ASL perfusions are difficult to assess separately due to limited spatial resolution increasing the partial volume effects (PVE). In the present study, ASL PVE correction was implemented based on a regression algorithm in 22 healthy young men. PVE corrected perfusion of GM and WM were compared to previous studies. PVE-corrected GM perfusion was in agreement with literature values. In general, WM perfusion was higher despite the use of PVE correction.

  • 5.
    Ambarki, Khalid
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Zarrinkoob, Laleh
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Wirestam, R.
    Petr, J.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-Labeling in Healthy Volunteers2015Inngår i: American Journal of Neuroradiology, ISSN 0195-6108, E-ISSN 1936-959X, Vol. 36, nr 10, 1816-1821 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    BACKGROUND AND PURPOSE: The arterial spin-labeling method for CBF assessment is widely available, but its accuracy is not fully established. We investigated the accuracy of a whole-brain arterial spin-labeling technique for assessing the mean parenchymal CBF and the effect of aging in healthy volunteers. Phase-contrast MR imaging was used as the reference method. MATERIALS AND METHODS: Ninety-two healthy volunteers were included: 49 young (age range, 20-30 years) and 43 elderly (age range, 65-80 years). Arterial spin-labeling parenchymal CBF values were averaged over the whole brain to quantify the mean pCBF(ASL) value. Total. CBF was assessed with phase-contrast MR imaging as the sum of flows in the internal carotid and vertebral arteries, and subsequent division by brain volume returned the pCBF(PCMRI) value. Accuracy was considered as good as that of the reference method if the systematic difference was less than 5 mL/min/100 g of brain tissue and if the 95% confidence intervals were equal to or better than +/- 10 mL/min/100 g. RESULTS: pCBF(ASL) correlated to pCBF(PCMRI) (r = 0.73; P < .001). Significant differences were observed between the pCBF(ASL) and pCBF(PCMRI) values in the young (P = .001) and the elderly (P < .001) volunteers. The systematic differences (mean 2 standard deviations) were -4 +/- 14 mL/min/100 g in the young subjects and 6 +/- 12 mL/min/100 g in the elderly subjects. Young subjects showed higher values than the elderly subjects for pCBF(PCMRI) (young, 57 +/- 8 mL/min/100 g; elderly, 54 +/- 7 mL/min/100 g; P = .05) and pCBF(ASL) (young, 61 +/- 10 mL/min/100 g; elderly, 48 +/- 10 mL/min/100 g; P < .001). CONCLUSIONS: The limits of agreement were too wide for the arterial spin-labeling method to be considered satisfactorily accurate, whereas the systematic overestimation in the young subjects and underestimation in the elderly subjects were close to acceptable. The age-related decrease in parenchymal CBF was augmented in arterial spin-labeling compared with phase-contrast MR imaging.

  • 6.
    Andersson, Jonas
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Ryberg, Mats
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Sjöström, Lars-Göran
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Wiklund, Urban
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Karpe, Fredrik
    NIHR Oxford Biomedical Research Centre, Churchill Hospital, Oxford, UK..
    Lindahl, Bernt
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin.
    Olsson, Tommy
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Long term effects of a diet intervention on adipose tissue blood flow, heart rate variability and endothelial function: a randomized controlled trialManuskript (preprint) (Annet vitenskapelig)
  • 7.
    Andersson, Kennet
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Manchester, I. R.
    Laurell, Katarina
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Cesarini, K. Giuliana
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Measurement of CSF dynamics with oscillating pressure infusion2013Inngår i: Acta Neurologica Scandinavica, ISSN 0001-6314, E-ISSN 1600-0404, Vol. 128, nr 1, 17-23 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Introduction Infusion tests are used to diagnose and select patients with idiopathic normal pressure hydrocephalus (INPH) for shunt surgery. The test characterizes cerebrospinal fluid dynamics and estimates parameters of the cerebrospinal fluid system, the pressure-volume index (PVI) and the outflow conductance (Cout). The Oscillating Pressure Infusion (OPI) method was developed to improve the test and reduce the investigation time. The aim of this study was to evaluate the new OPI method by comparing it with an established reference method. Methods Forty-seven patients (age 71.2 +/- 8.9years) with communicating hydrocephalus underwent a preoperative lumbar infusion investigation with two consecutive infusion protocols, reference (42min) and new (20min), that is, 94 infusion tests in total. The OPI method estimated Cout and PVI simultaneously. A real-time analysis of reliability was applied to investigate the possibility of infusion time reduction. Results The difference in Cout between the methods was 1.2 +/- 1.8l/s/kPa (Rout=-0.8 +/- 3.5mmHg/ml/min), P<0.05, n=47. With the reliability analysis, the preset 20min of active infusion could have been even further reduced for 19 patients to between 10 and 19min. PVI was estimated to 16.1 +/- 6.9ml, n=47. Conclusions The novel Oscillating Pressure Infusion method produced real-time estimates of Cout including estimates of reliability that was in good agreement with the reference method and allows for a reduced and individualized investigation time.

  • 8.
    Andersson, Kennet
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Manchester, Ian R
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Neurologi.
    Eklund, Anders
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Real-time estimation of cerebrospinal fluid system parameters via oscillating pressure infusion2010Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 48, nr 11, 1123-1131 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Hydrocephalus is related to a disturbed cerebrospinal fluid (CSF) system. For diagnosis, lumbar infusion test are performed to estimate outflow conductance, C (out), and pressure volume index, PVI, of the CSF system. Infusion patterns and analysis methods used in current clinical practice are not optimized. Minimizing the investigation time with sufficient accuracy is of major clinical relevance. The aim of this study was to propose and experimentally evaluate a new method, the oscillating pressure infusion (OPI). The non-linear model of the CSF system was transformed into a linear time invariant system. Using an oscillating pressure pattern and linear system identification methods, C (out) and PVI with confidence intervals, were estimated in real-time. Forty-two OPI and constant pressure infusion (CPI) investigations were performed on an experimental CSF system, designed with PVI = 25.5 ml and variable C (out). The ARX model robustly estimated C (out) (mean C (out,OPI) - C (out,CPI) = 0.08 μl/(s kPa), n = 42, P = 0.68). The Box-Jenkins model proved most reliable for PVI (23.7 ± 2.0 ml, n = 42). The OPI method, with its oscillating pressure pattern and new parameter estimation methods, efficiently estimated C (out) and PVI as well as their confidence intervals in real-time. The results from this experimental study show potential for the OPI method and supports further evaluation in a clinical setting.

  • 9.
    Backlund, Tomas
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Frankel, Jennifer
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Israelsson, Hanna
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap. Vrinnevi Hospital, Norrköping, Sweden.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Sundström, Nina
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Trunk sway in idiopathic normal pressure hydrocephalus: quantitative assessment in clinical practice2017Inngår i: Gait & Posture, ISSN 0966-6362, E-ISSN 1879-2219, Vol. 54, 62-70 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background: In diagnosis and treatment of patients with idiopathic normal pressure hydrocephalus (iNPH), there is need for clinically applicable, quantitative assessment of balance and gait. Using a body worn gyroscopic system, the aim of this study was to assess postural stability of iNPH patients in standing, walking and during sensory deprivation before and after cerebrospinal fluid (CSF) drainage and surgery. A comparison was performed between healthy elderly (HE) and patients with various types of hydrocephalus (ventriculomegaly (VM)). Methods: Trunk sway was measured in 31 iNPH patients, 22 VM patients and 58 HE. Measurements were performed at baseline in all subjects, after CSF drainage in both patient groups and after shunt surgery in the iNPH group. Results: Preoperatively, the iNPH patients had significantly higher trunk sway compared to HE, specifically for the standing tasks (p < 0.001). Compared to VM, iNPH patients had significantly lower sway velocity during gait in three of four cases on firm support (p < 0.05). Sway velocity improved after CSF drainage and in forward-backward direction after surgery (p < 0.01). Compared to HE both patient groups demonstrated less reliance on visual input to maintain stable posture. Conclusions: INPH patients had reduced postural stability compared to HE, particularly during standing, and for differentiation between iNPH and VM patients sway velocity during gait is a promising parameter. A reversible reduction of visual incorporation during standing was also seen. Thus, the gyroscopic system quantitatively assessed postural deficits in iNPH, making it a potentially useful tool for aiding in future diagnoses, choices of treatment and clinical follow-up. 

  • 10.
    Behrens, Anders
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap. Blekinge Centre of Competence, Blekinge Hospital Karlskrona, Karlskrona, Sweden.
    Eklund, Anders
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Elgh, Eva
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Psykiatri.
    Smith, Cynthia
    Williams, Michael A
    Malm, Jan
    A computerized neuropsychological test battery designed for idiopathic normal pressure hydrocephalus2014Inngår i: Fluids and Barriers of the CNS, ISSN 2045-8118, Vol. 11, 22Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    BACKGROUND: A tool for standardized and repeated neuropsychological assessments in patients with idiopathic normal pressure hydrocephalus (INPH) is needed. The objective of this study was to develop a computerized neuropsychological test battery designed for INPH and to evaluate its reliability, validity and patient's ability to complete the tests.

    METHODS: Based on a structured review of the literature on neuropsychological testing in INPH, the eight tests most sensitive to the INPH cognitive profile were implemented in a computerized format. The Geriatric Depression Scale (GDS) was also included. Tests were presented on a touch-screen monitor, with animated instructions and speaker sound. The battery was evaluated with the following cohorts: A. Test-retest reliability, 44 healthy elderly; B. Validity against standard pen and pencil testing, 28 patients with various cognitive impairments; C. Ability to complete test battery, defined as completion of at least seven of the eight tests, 40 investigated for INPH.

    RESULTS: A. All except the figure copy test showed good test-retest reliability, r = 0.67-0.90; B. A high correlation was seen between conventional and computerized tests (r = 0.66-0.85) except for delayed recognition and figure copy task; C. Seventy-eight percent completed the computerized battery; Patients diagnosed with INPH (n = 26) performed worse on all tests, including depression score, compared to healthy controls.

    CONCLUSIONS: A new computerized neuropsychological test battery designed for patients with communicating hydrocephalus and INPH was introduced. Its reliability, validity for general cognitive impairment and completion rate for INPH was promising. After exclusion of the figure copy task, the battery is ready for clinical evaluation and as a next step we suggest validation for INPH and a comparison before and after shunt surgery.

    TRIAL REGISTRATION: ClinicalTrials.org NCT01265251.

  • 11.
    Behrens, Anders
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Lenfeldt, Niklas
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Ambarki, Khalid
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Koskinen, Lars-Owe D
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Neurokirurgi.
    Intracranial Pressure and Pulsatility Index:  2011Inngår i: Neurosurgery, ISSN 0148-396X, E-ISSN 1524-4040, Vol. 69, nr 4, E1033-E1034 s.Artikkel i tidsskrift (Fagfellevurdert)
  • 12.
    Bodén, Ida
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Larsson, William
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
    Nilsson, David
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
    Forssell, Erik
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
    Naredi, Peter
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Lindholm-Sethson, Britta
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    In vivo skin measurements with a novel probe head for simultaneous skin impedance and near-infrared spectroscopy2011Inngår i: Skin research and technology, ISSN 0909-752X, E-ISSN 1600-0846, Vol. 17, nr 4, 494-504 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background/purpose: Near-infrared (NIR) spectroscopy and skin impedance (IMP) measurements are useful techniques for objective diagnostics of various skin diseases. Here, we present a combined probe head for simultaneous, time-saving NIR spectroscopy and skin impedance measurements. The probe also ensures that both measurements are performed under equal conditions and at the same skin location.

    Methods: Finite element method simulations were performed for evaluation of the impedance. In vivo skin measurements were performed and combined NIR and impedance spectra were analysed by means of multivariate methods with respect to body location, age and gender. The classification rate was determined by a planar discriminant analysis. Reproducibility was investigated by calculation of scatter values and statistical significance between overlapping groups was assessed by the calculation of intra-model distances, q.

    Results: The novel probe yielded rapid reproducible results and was easy to manage. Significant differences between skin locations and to a lesser extent age groups and gender were demonstrated.

    Conclusion: With the novel probe, statistically significant differences between overlapping classes in score plots can be confirmed by calculating intra-model distances. The influence of molecular differences in the skin at different body locations is larger than the influence of gender or age and therefore relevant reference measurements are discussed.

  • 13.
    Bodén, Ida
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Nilsson, David
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
    Naredi, Peter
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Lindholm-Sethson, Britta
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Characterization of healthy skin using near infrared spectroscopy and skin impedance2008Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 46, nr 10, 985-995 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Near infrared spectroscopy (NIR) and skin impedance (IMP) spectroscopy are two methods suggested for diagnoses of diseases inducing adverse effects in skin. The reproducibility of these methods and their potential value in non-invasive diagnostics were investigated. Measurements were performed in vivo on healthy skin at five anatomic body sites on eight young women. partial least squares discriminant analysis showed that both methods were useful for classification of the skin characteristics at the sites. Inter-individually the NIR model gave 100% correct classification while the IMP model provided 92%. Intra-individually the NIR model gave 88% correct classification whereas the IMP model did not provide any useful classification. The correct classification was increased to 93% when both datasets were combined, which demonstrates the value of adding information. Partial least squares discriminant analysis gave 72% correct predictions of skin sites while the combined model slightly improved to 73%.

  • 14.
    Bodén, Ida
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Nyström, Josefina
    Swedish University of Agricultural Sciences, Unit of Biomass Technology and Chemistry.
    Geladi, Paul
    Swedish University of Agricultural Sciences, Unit of Biomass Technology and Chemistry.
    Naredi, Peter
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Lindholm-Sethson, Britta
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
    NIR and skin impedance spectroscopic measurements for studying the effect of coffee and alcohol on skin, and dysplastic naevi2012Inngår i: Skin research and technology, ISSN 0909-752X, E-ISSN 1600-0846, Vol. 18, nr 4, 486-494 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background/purpose: Near infrared (NIR) and impedance spectroscopy can be used for clinical skin measurements and need to be evaluated for possible confounding factors; (a) are skin conditions of the patient and the subsequent skin measurements influenced by alcohol and/or coffee consumption and (b) are measurements of dysplastic naevi (DN) reproducible over time and significantly different compared to reference skin.

    Methods: NIR and skin impedance spectroscopic data were analysed multivariately. In the first study, the skin characteristics of 15 healthy individuals were examined related to body location, gender, individual differences, and consumption of coffee or alcohol. The second study included five patients diagnosed with dysplastic naevi syndrome (DNS). Measurements were taken on DN and reference skin over time.

    Results: In the first study, body location and gender had a major influence on measurement scores. Inter-individual skin characteristics and coffee or alcohol effects on skin characteristics were of minor importance. In the second study, it was shown that DN can be differentiated from reference skin and the measurements are stable over time.

    Conclusions: Moderate consumption of alcohol and coffee did not influence the results of the measurements. It is possible to follow, stable or changed, characteristics of DN over time.

  • 15.
    Brändström, Helge
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Anestesiologi och intensivvård.
    Grip, Helena
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Hallberg, Per
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Grönlund, Christer
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Ängquist, Karl-Axel
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
    Giesbrecht, Gordon G
    Hand cold recovery responses before and after 15 months of military training in a cold climate2008Inngår i: Aviation, Space and Environmental Medicine, ISSN 0095-6562, E-ISSN 1943-4448, Vol. 79, nr 9, 904-908 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    INTRODUCTION: The ability of fingers to rapidly rewarm following cold exposure is a possible indicator of cold injury protection. We categorized the post-cooling hand-rewarming responses of men before and after participation in 15 mo of military training in a cold environment in northern Sweden to determine: 1) if the initial rewarming category was related to the occurrence of local cold injury during training; and 2) if cold training affected subsequent hand-rewarming responses. METHODS: Immersion of the dominant hand in 10 degrees C water for 10 min was performed pre-training on 77 men. Of those, 45 were available for successful post-training retests. Infrared thermography monitored the dorsal hand during 30 min of recovery. Rewarming was categorized as normal, moderate, or slow based on mean fingertip temperature at the end of 30 min of recovery (TFinger,30) and the percentage of time that fingertips were vasodilated (%VD). RESULTS: Cold injury occurrence during training was disproportionately higher in the slow rewarmers (four of the five injuries). Post-training, baseline fingertip temperatures and cold recovery variables increased significantly in moderate and slow rewarmers: TFinger30 increased from 21.9 +/- 4 to 30.4 +/- 6 degrees C (Moderate), and from 17.4 +/- 0 to 22.3 +/- 7 degrees C (Slow); %VD increased from 27.5 +/- 16 to 65.9 +/- 34% (Moderate), and from 0.7 +/- 2 to 31.7 +/- 44% (Slow). CONCLUSIONS: Results of the cold recovery test were related to the occurrence of local cold injury during long-term cold-weather training. Cold training itself improved baseline and cold recovery in moderate and slow rewarmers.

  • 16.
    Burström, Lage
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.
    Hagberg, Mats
    Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital, Box 414, SE-405 30 Gothenburg, Sweden.
    Liljelind, Ingrid
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.
    Lundström, Ronnie
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Nilsson, Tohr
    Department of Occupational and Environmental Medicine, Sundsvall Hospital, Sundsvall, SE-851 86 Sweden.
    Pettersson, Hans
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.
    Wahlström, Jens
    Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital, Box 414, SE-405 30 Gothenburg, Sweden.
    A follow-up study of welders’ exposure to vibration in a heavy engineering production workshop2010Inngår i: Journal of Low Frequency Noise Vibration and Active Control, ISSN 0263-0923, Vol. 29, nr 1, 33-39 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Manual work involving vibrating power tools is associated with symptoms that include vascular, neurological and musculoskeletal disorders. This study examines the vibration exposure of welders to determine the change between 1987 and 2008. Vibration measurements on handheld tools were used to evaluate the acceleration and the daily exposure time was determined by subjective rating. From these data, the 8-hour equivalent vibration exposure A(8), has been calculated. During the period, the A(8) decreased from 3.9 m/s2 to 1.9 m/s2. It was concluded that this decrease is the result of fewer vibrating tools and a decrease in daily exposure time. Although the daily vibration exposure has decreased over the study time, for some welders the daily vibration exposure A(8) is still above the action value set by the EU directive on vibration. This means more effort should be spent to decrease vibration exposure.

  • 17.
    Candefjord, Stefan
    et al.
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Nyberg, Morgan
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Jalkanen, Ville
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
    Ramser, Kerstin
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Lindahl, Olof
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Combining fibre optic Raman spectroscopy and tactile resonance measurement for tissue characterization2010Inngår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 21, nr 125801, 1-8 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Tissue characterization is fundamental for identification of pathological conditions. Raman spectroscopy (RS) and tactile resonance measurement (TRM) are two promising techniques that measure biochemical content and stiffness, respectively. They have potential to complement the golden standard-–histological analysis. By combining RS and TRM, complementary information about tissue content can be obtained and specific drawbacks can be avoided. The aim of this study was to develop a multivariate approach to compare RS and TRM information. The approach was evaluated on measurements at the same points on porcine abdominal tissue. The measurement points were divided into five groups by multivariate analysis of the RS data. A regression analysis was performed and receiver operating characteristic (ROC) curves were used to compare the RS and TRM data. TRM identified one group efficiently (area under ROC curve 0.99). The RS data showed that the proportion of saturated fat was high in this group. The regression analysis showed that stiffness was mainly determined by the amount of fat and its composition. We concluded that RS provided additional, important information for tissue identification that was not provided by TRM alone. The results are promising for development of a method combining RS and TRM for intraoperative tissue characterization.

  • 18.
    Candefjord, Stefan
    et al.
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Nyberg, Morgan
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Jalkanen, Ville
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Ramser, Kerstin
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Lindahl, Olof
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Evaluating the use of a Raman fiberoptic probe in conjunction with a resonance sensor for measuring porcine tissue in vitro2009Inngår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Heidelberg: Springer , 2009, 414-417 s.Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Prostate cancer is the most common form of cancer and is the third leading cause of cancer-related death in European men. There is a need for new methods that can accurately localize and diagnose prostate cancer. In this study a new approach is presented: a combination of resonance sensor technology and Raman spectroscopy. Both methods have shown promising results for prostate cancer detection in vitro. The aim of this study was to evaluate the combined information from measurements with a Raman fiberoptic probe and a resonance sensor system. Pork belly tissue was used as a model system. A three-dimensional translation table was equipped with an in-house developed software, allowing measurements to be performed at the same point using two separate instruments. The Raman data was analyzed using principal component analysis and hierarchical clustering analysis. The spectra were divided into 5 distinct groups. The mean stiffness of each group was calculated from the resonance sensor measurements. One of the groups differed significantly (p < 0.05) from the others. A regression analysis, with the stiffness parameter as response variable and the principal component scores of the Raman data as the predictor variables, explained 67% of the total variability. The use of a smaller resonance sensor tip would probably increase the degree of correlation. In conclusion, Raman spectroscopy provides additional discriminatory power to the resonance sensor.

  • 19.
    Candefjord, Stefan
    et al.
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Nyberg, Morgan
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Jalkanen, Ville
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Ramser, Kerstin
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Lindahl, Olof
    Dept. of Computer Science and Electrical Engineering, Luleå University of Technology.
    Kombinationsinstrument för detektering av prostatacancer: korrelation mellan resonanssensor och fiberoptisk Ramanprobe2009Inngår i: Medicinteknikdagarna 2009, Svensk förening för medicinsk teknik och fysik , 2009, 60- s.Konferansepaper (Fagfellevurdert)
  • 20.
    Dunås, Tora
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Ambarki, Khalid
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Zarrinkoob, Laleh
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    A Stereotactic Probabilistic Atlas for the Major Cerebral Arteries2017Inngår i: Neuroinformatics, ISSN 1539-2791, E-ISSN 1559-0089, Vol. 15, nr 1, 101-110 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Improved whole brain angiographic and velocity-sensitive MRI is pushing the boundaries of noninvasively obtained cerebral vascular flow information. The complexity of the information contained in such datasets calls for automated algorithms and pipelines, thus reducing the need of manual analyses by trained radiologists. The objective of this work was to lay the foundation for such automated pipelining by constructing and evaluating a probabilistic atlas describing the shape and location of the major cerebral arteries. Specifically, we investigated how the implementation of a non-linear normalization into Montreal Neurological Institute (MNI) space improved the alignment of individual arterial branches. In a population-based cohort of 167 subjects, age 64-68 years, we performed 4D flow MRI with whole brain volumetric coverage, yielding both angiographic and anatomical data. For each subject, sixteen cerebral arteries were manually labeled to construct the atlas. Angiographic data were normalized to MNI space using both rigid-body and non-linear transformations obtained from anatomical images. The alignment of arterial branches was significantly improved by the non-linear normalization (p < 0.001). Validation of the atlas was based on its applicability in automatic arterial labeling. A leave-one-out validation scheme revealed a labeling accuracy of 96 %. Arterial labeling was also performed in a separate clinical sample (n = 10) with an accuracy of 92.5 %. In conclusion, using non-linear spatial normalization we constructed an artery-specific probabilistic atlas, useful for cerebral arterial labeling.

  • 21.
    Dunås, Tora
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Zarrinkoob, Laleh
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Ambarki, Khalid
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Towards Automatic Identification of Cerebral Arteries in 4D Flow MRI2015Inngår i: 16th Nordic-Baltic Conference on Biomedical Engineering / [ed] Henrik Mindedal, Mikael Persson, 2015, Vol. 48, 40-43 s.Konferansepaper (Fagfellevurdert)
    Abstract [en]

    4D flow MRI is a powerful imaging technique which provides an angiographic image with information about blood flow in a large volume, time resolved over the cardiac cycle, in a short imaging time. This study aims to develop an automatic method for identification of cerebral arteries. The proposed method is based on an atlas of twelve arteries, developed from 4D flow MRI of 25 subjects. The atlas was constructed by normalizing all images to MNI-space, manually identifying the arteries and creating an average over the volume. The identification is done by extracting a vascular skeleton from the image, transforming it to MNI-space, labeling it with the atlas and transforming it back to subject space. The method was evaluated on a pilot cohort of 8 subjects. The rate of correctly identified arteries was 97%.

  • 22.
    Duvaldt, Maria
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik. Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Karolinska Universitetssjukhuset Huddinge.
    Developing a Semi-Automatised Tool for Grading Brain Tumours with Susceptibility-Weighted MRI2015Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
    Abstract [en]

    Gliomas are a common type of brain tumour and for the treatment of a patient it is important to determine the tumour’s grade of malignancy. This is done today by a biopsy, a histopathological analysis of the tumourous tissue, that is classified by the World Health Organization on a malignancy scale from I to IV. Recent studies have shown that the local image variance (LIV) and the intratumoural susceptibility signal (ITSS) in susceptibility-weighted MR images correlate to the tumour grade. This thesis project aims to develop a software program as aid for the radiologists when grading a glioma. The software should by image analysis be able to separate the gliomas into low grade (I-II) and high grade (III-IV). The result is a graphical user interface written in Python 3.4.3. The user chooses an image, draws a region of interest and starts the analysis. The analyses implemented in the program are LIV and ITSS mentioned above, and the code can be extended to contain other types of analyses as research progresses. To validate the image analysis, 16 patients with glioma grades confirmed by biopsy are included in the study. Their susceptibility-weighted MR images were analysed with respect to LIV and ITSS, and the outcome of those image analyses was tested versus the known grades of the patients. No statistically significant difference could be seen between the high and the low grade group, in the case of LIV. This was probably due to hemorrhage and calcification, characteristic for some tumours and interpreted as blood vessels. Concerning ITSS a statistically significant difference could be seen between the high and the low grade group (p < 0.02). The sensitivity and specificity was 80% and 100% respec- tively. Among these 16 gliomas, 11 were astrocytic tumours and between low and high grade astrocytomas a statistically significant difference was shown. The degree of LIV was significantly different between the two groups (p < 0.03) and the sensitivity and specificity were 86% and 100% respectively. The degree of ITSS was significantly different between the two groups (p < 0.04) and the sensitivity and specificity were 86% and 100% respectively. Spearman correlation showed a correlation between LIV and tumour grade (for all gliomas r = 0.53 and p < 0.04, for astrocytomas r = 0.84 and p < 0.01). A correlation was also found between ITSS and tumour grade (for all gliomas r = 0.69 and p < 0.01, for astrocytomas r = 0.63 and p < 0.04). The results indicate that SWI is useful for distinguishing between high and low grade astrocytoma with 1.5T imaging within this cohort. It also seems possible to distinguish between high and low grade glioma with ITSS.

  • 23.
    Eklund, Anders
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Jóhannesson, Gauti
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
    Johansson, Elias
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Farmakologi.
    Holmlund, Petter
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Qvarlander, Sara
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Ambarki, Khalid
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Wåhlin, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).
    Koskinen, Lars-Owe D.
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Farmakologi.
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
    The Pressure Difference between Eye and Brain Changes with Posture2016Inngår i: Annals of Neurology, ISSN 0364-5134, E-ISSN 1531-8249, Vol. 80, nr 2, 269-276 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Objective: The discovery of a posture-dependent effect on the difference between intraocular pressure (IOP) and intracranial pressure (ICP) at the level of lamina cribrosa could have important implications for understanding glaucoma and idiopathic intracranial hypertension and could help explain visual impairments in astronauts exposed to microgravity. The aim of this study was to determine the postural influence on the difference between simultaneously measured ICP and IOP.

    Methods: Eleven healthy adult volunteers (age = 46 ± 10 years) were investigated with simultaneous ICP, assessed through lumbar puncture, and IOP measurements when supine, sitting, and in 9° head-down tilt (HDT). The trans–lamina cribrosa pressure difference (TLCPD) was calculated as the difference between the IOP and ICP. To estimate the pressures at the lamina cribrosa, geometrical distances were estimated from magnetic resonance imaging and used to adjust for hydrostatic effects.

    Results: The TLCPD (in millimeters of mercury) between IOP and ICP was 12.3 ± 2.2 for supine, 19.8 ± 4.6 for sitting, and 6.6 ± 2.5 for HDT. The expected 24-hour average TLCPD on earth—assuming 8 hours supine and 16 hours upright—was estimated to be 17.3mmHg. By removing the hydrostatic effects on pressure, a corresponding 24-hour average TLCPD in microgravity environment was simulated to be 6.7mmHg.

    Interpretation: We provide a possible physiological explanation for how microgravity can cause symptoms similar to those seen in patients with elevated ICP. The observed posture dependency of TLCPD also implies that assessment of the difference between IOP and ICP in upright position may offer new understanding of the pathophysiology of idiopathic intracranial hypertension and glaucoma. 

  • 24.
    Eklund, Anders
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Lindén, Christina
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap.
    Bäcklund, Tomas
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Andersson, Britt M
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Lindahl, Olof A
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Evaluation of applanation resonator sensors for intra-ocular pressure measurement: results from clinical and in vitro studies.2003Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 41, nr 2, 190-197 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.

  • 25. Ertzgaard, Per
    et al.
    Öhberg, Fredrik
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Gerdle, Björn
    Grip, Helena
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    A new way of assessing arm function in activity using kinematic Exposure Variation Analysis and portable inertial sensors - A validity study2016Inngår i: Manual Therapy, ISSN 1356-689X, E-ISSN 1532-2769, Vol. 21, 241-249 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Portable motion systems based on inertial motion sensors are promising methods, with the advantage compared to optoelectronic cameras of not being confined to a laboratory setting. A challenge is to develop relevant outcome measures for clinical use. The aim of this study was to characterize elbow and shoulder motion during functional tasks, using portable motion sensors and a modified Exposure Variation Analysis (EVA) and evaluate system accuracy with optoelectronic cameras. Ten healthy volunteers and one participant with sequel after stroke performed standardised functional arm tasks. Motion was registered simultaneously with a custom developed motion sensor system, including gyroscopes and accelerometers, and an optoelectronic camera system. The EVA was applied on elbow and shoulder joints, and angular and angular velocity EVA plots was calculated. The EVA showed characteristic patterns for each arm task in the healthy controls and a distinct difference between the affected and unaffected arm in the participant with sequel after stroke. The accuracy of the portable system was high with a systematic error ranging between -1.2 degrees and 2.0 degrees. The error was direction specific due to a drift component along the gravity vector. Portable motion sensor systems have high potential as clinical tools for evaluation of arm function. EVA effectively illustrates joint angle and joint angle velocity patterns that may capture deficiencies in arm function and movement quality. Next step will be to manage system drift by including magnetometers, to further develop clinically relevant outcome variables and apply this for relevant patient groups.

  • 26.
    Grönlund, Christer
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Claesson, Kenji
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    D Hooge, Jan
    Department of Cardiovascular sciences, Leuven, Belgium.
    Henein, Michael Y
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi. Umeå Heart Centre.
    Lindqvist, Per
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi. Umeå Heart Centre.
    Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging2013Inngår i: Biomedical engineering online, ISSN 1475-925X, Vol. 12, nr 1, 107- s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    BACKGROUND: Ultrasound imaging of the heart is a commonly used clinical tool to assess cardiac function. The basis for this analysis is the quantification of cardiac blood flow and myocardial velocities. These are typically measured using different imaging modes and on different cardiac cycles. However, due to beat-to-beat variations such as irregular heart rhythm and transient events, simultaneous acquisition is preferred. There exists specialized ultrasound systems for this purpose; however, it would be beneficial if this could be achieved using conventional ultrasound systems due to their wide availability. The conventional Duplex mode ultrasound allows simultaneous acquisition, however at a highly reduced spatial and temporal resolution.

    METHODS: The aim of this work was to present and evaluate the performance of a novel method to recover myocardial tissue velocity using conventional Duplex ultrasound imaging, and to demonstrate its feasibility for the assessment of simultaneous blood flow and myocardial velocity in-vivo. The essence of the method was the estimation of the axial phase shift of robust echogenic structures between subsequent image frames. The performance of the method was evaluated on synthetic tissue mimicking B-mode image sequences at different frame rates (20--60 Hz) and tissue velocities (peak velocities 5-15cm/s), using cardiac deformation and displacement characteristics. The performance was also compared to a standard 2-D speckle tracking technique.

    RESULTS: The method had an overall high performance at frame rates above 25 Hz, with less than 15% error of the peak diastolic velocity, and less than 10 ms peak timing error. The method showed superior performance compared to the 2-D tracking technique at frame rates below 50 Hz. The in-vivo quantification of simultaneous blood flow and myocardial tissue velocities verified the echocardiographic patterns and features of healthy subjects and the specific patient group.

    CONCLUSIONS: A novel myocardial velocity quantification method was presented and high performance at frame rates above 25Hz was shown. In-vivo quantification of simultaneous myocardial and blood flow velocities was feasible using the proposed method and conventional Duplex mode imaging. We propose that the methodology is suitable for retrospective as well as prospective studies on the mechanics and hemodynamics of the heart.

  • 27.
    Grönlund, Christer
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Claesson, Kenji
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Holtermannz, Andreas
    Imaging two-dimensional mechanical waves of skeletal muscle contraction2013Inngår i: Ultrasound in Medicine and Biology, ISSN 0301-5629, Vol. 39, nr 2, 360-369 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Skeletal muscle contraction is related to rapid mechanical shortening and thickening. Recently, specialized ultrasound systems have been applied to demonstrate and quantify transient tissue velocities and one-dimensional (1-D) propagation of mechanical waves during muscle contraction. Such waves could potentially provide novel information on musculoskeletal characteristics, function and disorders. In this work, we demonstrate two-dimensional (2-D) mechanical wave imaging following the skeletal muscle contraction. B-mode image acquisition during multiple consecutive electrostimulations, speckle-tracking and a time-stamp sorting protocol were used to obtain 1.4 kHz frame rate 2-D tissue velocity imaging of the biceps brachii muscle contraction. The results present novel information on tissue velocity profiles and mechanical wave propagation. In particular, counter-propagating compressional and shear waves in the longitudinal direction were observed in the contracting tissue (speed 2.8-4.4 m/s) and a compressional wave in the transverse direction of the non-contracting muscle tissue (1.2-1.9 m/s). In conclusion, analysing transient 2-D tissue velocity allows simultaneous assessment of both active and passive muscle tissue properties. (E-mail: christer.gronlund@vll.se) (C) 2013 World Federation for Ultrasound in Medicine & Biology.

  • 28.
    Grönlund, Christer
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Östlund, Nils
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Lindh, Jack
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Bergström, Per
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
    Karlsson, Stefan J
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
    Spatio-temporal processing of surface EMG signals from the sternocleidomastoideus muscle to assess effects of radiotherapy on motor unit conduction velocity and firing rate: a pilot study2008Inngår i: Biomedical Signal Processing and Control, ISSN 1746-8094, Vol. 3, nr 2, 163-168 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Radiation therapy causes both muscle and nerve tissue damage. However, the evolution and mechanisms of these damages are not fully understood. Information on the state of active muscle fibres and motoneurons can be obtained by measuring sEMG signals and calculating the conduction velocity (CV) and firing rate of individual motor units, respectively. The aim of this pilot study was to evaluate if the multi-channel surface EMG (sEMG) technique could be applied to the sternocleidomastoideus muscle (SCM) of radiotherapy patients, and to assess if the CV and firing rate are altered as a consequence of the radiation.

    Surface EMG signals were recorded from the radiated and healthy SCM muscles of 10 subjects, while subjects performed isometric rotation of the head. CV and firing rate were calculated using two recently proposed methods based on spatio-temporal processing of the sEMG signals. The multi-channel sEMG technique was successfully applied to the SCM muscle and CV and firing rates were obtained. The measurements were fast and simple and comfortable for the patients. Sufficient data quality was obtained from both sides of seven and four subjects for the CV and firing rate analysis, respectively. No differences in CV or firing rate were found between the radiated and non-radiated sides (p = 0.13 and p = 0.20, respectively). Firing rate and CV were also obtained from a myokymic discharge pattern. It was found that the CV decreased significantly (p = 0.01) during the bursts.

  • 29.
    Gustavsson, Sandra
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Klinisk fysiologi. Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi.
    Granåsen, Gabriel
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Grönlund, Christer
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Wiklund, Urban
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Mörner, Stellan
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi.
    Henein, Michael
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi.
    Suhr, Ole B
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
    Lindqvist, Per
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Klinisk fysiologi. Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi.
    Can echocardiography and ECG discriminate hereditary transthyretin V30M amyloidosis from hypertrophic cardiomyopathy?2015Inngår i: Amyloid: Journal of Protein Folding Disorders, ISSN 1350-6129, E-ISSN 1744-2818, Vol. 22, nr 3, 163-170 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Objective: Hereditary transthyretin (ATTR) amyloidosis with increased left ventricular wall thickness could easily be misdiagnosed by echocardiography as hypertrophic cardiomyopathy (HCM). Our aim was to create a diagnostic tool based on echocardiography and ECG that could optimise identification of ATTR amyloidosis. Methods: Data were analysed from 33 patients with biopsy proven ATTR amyloidosis and 30 patients with diagnosed HCM. Conventional features from ECG were acquired as well as two dimensional and Doppler echocardiography, speckle tracking derived strain and tissue characterisation analysis. Classification trees were used to select the most important variables for differentiation between ATTR amyloidosis and HCM. Results: The best classification was obtained using both ECG and echocardiographic features, where a QRS voltage >30 mm was diagnostic for HCM, whereas in patients with QRS voltage <30 mm, an interventricular septal/posterior wall thickness ratio (IVSt/PWt) >1.6 was consistent with HCM and a ratio <1.6 supported the diagnosis of ATTR amyloidosis. This classification presented both high sensitivity (0.939) and specificity (0.833). Conclusion: Our study proposes an easily interpretable classification method for the differentiation between HCM and increased left ventricular myocardial thickness due to ATTR amyloidosis. Our combined echocardiographic and ECG model could increase the ability to identify ATTR cardiac amyloidosis in clinical practice.

  • 30.
    Hallberg, Per
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Lindén, Christina
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
    Bäcklund, Tomas
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Symmetric sensor for applanation resonance tonometry of the eye2006Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 44, nr 1-2, 54-60 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Applanation resonance tonometry (ART) has been shown in a number of studies to be useful for measuring intraocular pressure (IOP). Data from in vitro laboratory bench testing, where the sensor was carefully centralised onto the cornea, has been very consistent with good precision in the determination of IOP. However, in a clinical study the unavoidable off-centre placement of the sensor against the cornea resulted in a reduced precision. The aim of this study was to evaluate a new design of the sensor with a symmetric sensor probe and a contact piece with a larger diameter. Two in vitro porcine eye experimental set-ups were used. One bench-based for examining position dependence and one biomicroscope-based set-up, simulating a clinical setting, for evaluating IOP(ART) precision at seven different pressure levels (1040 mmHg), set by connecting a saline column to the vitreous chamber. The reference IOP was recorded using a pressure transducer. There was no significant difference between four positions 1 mm off centre and the one centre position. The precision of the ART as compared with the reference pressure was +/- 1.03 mmHg (SD, n = 42). The design improvement has enhanced the precision of the ART in the biomicroscope set-up to be in parity with bench test results from a set-up using perfect positioning. This indicates that off-centre positioning was no longer a major contributor to the deviations in measured IOP. The precision was well within the limits set by ISO standard for eye tonometers. Therefore, a larger in vivo study on human eyes with the ART should be performed.

  • 31.
    Hallberg, Per
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Lindén, Christina
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
    Lindahl, Olof A.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Bäcklund, Tomas
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Eklund, Anders
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Applanation resonance tonometry for intraocular pressure in humans2004Inngår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 25, nr 4, 1053-1065 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Glaucoma is a group of diseases associated with optic nerve damage and loss of visual field. The aetiology is not completely understood, but one of the major risk factors is elevated intraocular pressure (IOP). Reliable methods for measuring the IOP are therefore important. The aim of the study was to investigate the ability of the applanation resonance tonometry (ART) system, based on continuous force and area recording, to measure IOP in humans. Both the phase of initial indentation (IOPIndentation) and the phase when the sensor was removed (IOPRemoval) from the cornea were analysed. The Goldmann applanation tonometry (GAT) was used as reference method. The study included 24 healthy volunteers with normal IOP and 24 patients with elevated IOP. The correlation and standard deviation (SD) between IOPIndentation and IOPGAT was R = 0.92 (p < 0.001), SD = 3.6 mmHg, n = 104, and between IOPRemoval and IOPGAT R = 0.94 (p < 0.001), SD = 3.1 mmHg, n = 104. In conclusion, resonance sensor technology has made it possible to introduce a new multi-point method for measuring IOP, and the method is relevant for measuring IOP in humans. The study indicates that with further development towards elimination of position dependence, the ART has the potential to become a useful clinical instrument for IOP measurement.

  • 32.
    Hallberg, Per
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Santala, Kenneth
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
    Lindén, Christina
    Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
    Lindahl, Olof A
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model2006Inngår i: J Med Eng Technol, ISSN 0309-1902, Vol. 30, nr 6, 345-352 s.Artikkel i tidsskrift (Fagfellevurdert)
  • 33.
    Holtermann, A
    et al.
    Human Movement Sciences Programme, Norwegian University of Science and Technology, Trondheim, Norway.
    Grönlund, Christer
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Ingebrigtsen, J
    Human Movement Sciences Programme, Norwegian University of Science and Technology, Trondheim, Norway.
    Karlsson, J Stefan
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Roeleveld, K
    Human Movement Sciences Programme, Norwegian University of Science and Technology, Trondheim, Norway.
    Duration of differential activations is functionally related to fatigue prevention during low-level contractions.2010Inngår i: Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology, ISSN 1873-5711, Vol. 20, nr 2, 241-245 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The aim of this study was to investigate the importance of duration of differential activations between the heads of the biceps brachii on local fatigue during prolonged low-level contractions. Fifteen subjects carried out isometric elbow flexion at 5% of maximal voluntary contraction (MVC) for 30 min. MVCs were performed before and at the end of the prolonged contraction. Surface electromyographic (EMG) signals were recorded from both heads of the biceps brachii. Differential activation was analysed based on the difference in EMG amplitude (activation) between electrodes situated at the two heads. Differential activations were quantified by the power spectral median frequency of the difference in activation between the heads throughout the contraction. The inverse of the median frequency was used to describe the average duration of the differential activations. The relation between average duration of the differential activations and the fatigue-induced reduction in maximal force was explored by linear regression analysis. The main finding was that the average duration of differential activation was positively associated to relative maximal force at the end of the 30 min contraction (R(2)=0.5, P<0.01). The findings of this study highlight the importance of duration of differential activations for local fatigue, and support the hypothesis that long term differential activations prevent fatigue during prolonged low-level contractions.

  • 34.
    Israelsson, Hanna
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap. Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
    Carlberg, Bo
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin.
    Wikkelsö, Carsten
    Laurell, Katarina
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Kahlon, Babar
    Leijon, Göran
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Vascular risk factors contribute to idiopathic normal pressure hydrocephalus: the INPH-CRasH StudyManuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    Objective

    The objective was to determine the complete modern vascular risk factor (VRF) profile of idiopathic normal pressure hydrocephalus (INPH) using a large sample of representative INPH-patients and population-based controls, in order to confirm the impact of vascular disease on INPH pathophysiology.

     

    Methods

    All shunted INPH-patients in Sweden 2008-2010 were compared to age- and gender-matched population-based controls. Inclusion criteria: 60-85 years and mini mental state estimation ³23. The ten most important modern VRFs as well as cerebrovascular and peripheral vascular disease were prospectively assessed through blood samples, by-protocol clinical examinations and standardized questionnaires. Investigated VRFs: hypertension, hyperlipidemia, diabetes, obesity, psychosocial factors, smoking, diet, alcohol intake, cardiac disease and, physical activity.

     

    Results

    After exclusion, 176 INPH-patients and 368 controls participated. Using multivariable logistic regression, hyperlipidemia (OR: 2.380, 95%CI: 1.434-3.950), diabetes (OR: 2.169, 95%CI: 1.195-3.938), obesity (OR: 5.428, 95%CI: 2.502-11.772) and, psychosocial factors (OR: 5.343, 95%CI: 3.219-8.868) were independently associated with INPH. Hypertension, physical inactivity, cerebrovascular and peripheral vascular disease were overrepresented in INPH, although not independently. The protective factors: moderate alcohol intake and physical activity were overrepresented among the controls. The population attributable risk percentage was 24%.

     

    Conclusions

    Our findings confirm that INPH-patients have a more dangerous VRF-profile and lack the protective factors present in the population. Almost one quarter of INPH could be explained by VRF, suggesting that INPH possibly may be a subgroup of vascular dementia. Targeted interventions against modifiable VRF are likely to have beneficial effects in INPH.

  • 35.
    Israelsson, Hanna
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Carlberg, Bo
    Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin.
    Wikkelsö, Carsten
    Laurell, Katarina
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Kahlon, Babar
    Leijon, Göran
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Vascular risk factors in INPH A prospective case- control study (the INPH-CRasH study)2017Inngår i: Neurology, ISSN 0028-3878, E-ISSN 1526-632X, Vol. 88, nr 6, 577-585 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Objective: To assess the complete vascular risk factor (VRF) profile of idiopathic normal pressure hydrocephalus (INPH) using a large sample of representative patients with INPH and populationbased controls to determine the extent to which vascular disease influences INPH pathophysiology. Methods: All patients with INPH who underwent shunting in Sweden in 2008-2010 were compared to age-and sex-matched population-based controls. Inclusion criteria were age 60-85 years and no dementia. The 10 most important VRFs and cerebrovascular and peripheral vascular disease were prospectively assessed using blood samples, clinical examinations, and standardized questionnaires. Assessed VRFs were hypertension, hyperlipidemia, diabetes, obesity, psychosocial factors, smoking habits, diet, alcohol intake, cardiac disease, and physical activity. Results: In total, 176 patients with INPH and 368 controls participated. Multivariable logistic regression analysis indicated that hyperlipidemia (odds ratio [OR] 2.380; 95% confidence interval [CI] 1.434-3.950), diabetes (OR 2.169; 95% CI 1.195-3.938), obesity (OR 5.428; 95% CI 2.502-11.772), and psychosocial factors (OR 5.343; 95% CI 3.219-8.868) were independently associated with INPH. Hypertension, physical inactivity, and cerebrovascular and peripheral vascular disease were also overrepresented in INPH. Moderate alcohol intake and physical activity were overrepresented among the controls. The population-attributable risk percentage was 24%. Conclusions: Our findings confirm that patients with INPH have more VRFs and lack the protective factors present in the general population. Almost 25% of cases of INPH may be explained by VRFs. This suggests that INPH may be a subtype of vascular dementia. Targeted interventions against modifiable VRFs are likely to have beneficial effects on INPH.

  • 36.
    Israelsson, Hanna
    et al.
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    Eklund, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Malm, Jan
    Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.
    CSF shunting improves long-term quality of life in idiopathic normal pressure hydrocephalus: the INPH-CRasH StudyManuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    Introduction

    Measurements of quality of life (QoL) are important when evaluating a surgical method. However, QoL after shunting in idiopathic normal pressure hydrocephalus (INPH) is seldom assessed. The objective of this study was to assess QoL in a large cohort of shunted INPH patients, compared to the population, and investigate which factors influence QoL in INPH.

     

    Methods

    All INPH patients shunted in Sweden 2008-2010 were scrutinized. Population-based controls were age- and gender-matched to the patients. One hundred and seventy-six INPH patients and 368 controls were included. QoL was assessed using the EQ5D5L instrument, measuring overall QoL and health status in five dimensions. Independency, measured by accommodation and need for in-home care, and comorbidities were assessed. Patients were followed up 6-45 months after surgery (mean follow-up time: 21 months).

     

    Results

    Shunted INPH patients had lower QoL than controls (p<0.001). The patients’ health status in mobility, self-care, daily activities, and anxiety/depression was worse than the controls both before and after surgery (p<0.001). Shunting improved QoL (p<0.001) and health status in all dimensions (p<0.005). The main predictors of low QoL in INPH were depression (p<0.001) and severity of gait disturbance (p=0.001). Fewer INPH patients than controls lived independently (45% vs 85%, p<0.001) Time after shunting had no influence on QoL.

     

    Interpretation

    Improvement in QoL after shunting in INPH is long lasting, but shunted INPH patients do not reach the same level of QoL as the population. Depression and severity of gait disturbance are the strongest predictors of low QoL in INPH. 

  • 37.
    Jalkanen, Ville
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Hand-held resonance sensor for tissue stiffness measurements: a theoretical and experimental analysis2010Inngår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 21, nr 055801, 8pp- s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    A piezoelectric transducer in a feedback circuit operating in a resonance state is the basis of a resonance sensor. Upon contact with a soft object a change in the resonance frequency reflects the acoustic impedance. Together with force measurement it is possible to obtain the elastic stiffness of the object. The aim of this study was to evaluate the concept of a hand-held resonance sensor for tissue stiffness measurement. A time derivative analysis of the force and the frequency change showed that a stiffness-sensitive parameter was independent of the impression speed. Soft tissue phantoms of gelatin were used in an experimental validation of the theory. A force indentation method was used as a reference method for assessing the gelatin's elastic stiffness. Results from the hand-held measurements showed that the stiffness parameter accurately measured the elastic stiffness of the gelatin (R2 = 0.94, p < 0.05). The stiffness parameter was weakly (on average R2 = 0.15) and non-significantly (p > 0.05, 14 out of 17) dependent on an impression speed parameter. On average, a small amount of the total variance was explained by the impression speed. In conclusion, soft tissue stiffness can be objectively measured with free-hand measurement with a resonance sensor. This study contributes a theoretical analysis and an experimental demonstration of the concept of a hand-held resonance sensor for stiffness measurements.

  • 38.
    Jalkanen, Ville
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Handheld resonance sensor instrumentation towards faster diagnosis of prostate cancer: stiffness measurements on a soft tissue phantom2009Inngår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Heidelberg: Springer , 2009, 808-811 s.Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Prostate cancer is the most common type of cancer among men. Standard methods for detecting and diagnosing prostate cancer are not sensitive enough. Radical prostatectomy is a procedure where the prostate is removed as a treatment for prostate cancer. Objectively measured prostate stiffness could be a clinical marker for prostate cancer and this could be accomplished with a stiffness sensitive resonance sensor. A future handheld pen-like resonance sensor instrument could be a valuable clinical tool for locating cancer during radical prostatectomy surgery and thus aid in the diagnosis and treatment. The aim of this study was to evaluate the concept of a handheld resonance sensor for stiffness measurements on a soft tissue phantom. For a handheld resonance sensor set-up the impression depth and speed of the sensor tip into the tissue are unknown. A theoretical model was derived to show that a stiffness sensitive parameter can be obtained independent of the impression depth and the impression speed. The theoretical result was verified on a soft tissue phantom made of gelatin with a silicon tumor inclusion. These results were promising for further studies and development of a handheld instrument towards faster diagnosis of prostate cancer.

  • 39.
    Jalkanen, Ville
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Handhållen resonanssensor för styvhetsmätning av vävnadsmodeller2009Inngår i: Medicinteknikdagarna 2009, Svensk förening för medicinsk teknik och fysik , 2009, 62- s.Konferansepaper (Fagfellevurdert)
  • 40.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Andersson, Britt
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Bergh, Anders
    Umeå universitet, Medicinsk fakultet, Medicinsk biovetenskap. Umeå universitet, Medicinsk fakultet, Medicinsk biovetenskap, Patologi.
    Ljungberg, Börje
    Umeå universitet, Medicinsk fakultet, Kirurgisk och perioperativ vetenskap. Umeå universitet, Medicinsk fakultet, Kirurgisk och perioperativ vetenskap, Urologi och andrologi.
    Lindahl, Olof
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Detection of prostate cancer with a resonance sensor2005Inngår i: IFMBE Proccedings: NBC'05 Umeå 13th Nordic Baltic Conferenceon Biomedical Engineering and Medical Physics, Umeå, 2005, 130-131 s.Konferansepaper (Fagfellevurdert)
  • 41.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Andersson, Britt
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Bergh, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Patologi.
    Ljungberg, Börje
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Urologi och andrologi.
    Lindahl, Olof
    Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Indentation loading response of a resonance sensor: discriminating prostate cancer and normal tissue2013Inngår i: Journal of Medical Engineering & Technology, ISSN 0309-1902, E-ISSN 1464-522X, Vol. 37, nr 7, 416-423 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Prostate cancer is the most common type of cancer among men worldwide. Mechanical properties of prostate tissue are promising for distinguishing prostate cancer from healthy prostate tissue. The aim was to investigate the indentation loading response of a resonance sensor for discriminating prostate cancer tissue from normal tissue. Indentation measurements were done on prostate tissue specimens ex vivo from 10 patients from radical prostatectomy. The measurement areas were analysed using standard histological methods. The stiffness parameter was linearly dependent on the loading force (average R2 = 0.90) and an increased loading force caused a greater stiffness contrast of prostate cancer vs normal tissue. The accuracy of the stiffness contrast was assessed by the ROC curve with the area under the curve being 0.941 for a loading force of 12.8 mN. The results are promising for the development of a resonance sensor instrument for detecting prostate cancer.

  • 42.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Andersson, Britt
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Eklund, Anders
    Medicinsk teknik och informatik, Biomedical Engineering and Informatics, Umeå University Hospital.
    Lindahl, Olof
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    A resonance sensor technique to detect cancer in prostate - Model experiments in silicone2002Inngår i: IFMBE Proceedings: The 12th Nordic Baltic Conference on Biomedical Engineering and Medical Physics, Reykjavik, 2002, 33-34 s.Konferansepaper (Fagfellevurdert)
  • 43.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Andersson, Britt
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Lindahl, Olof
    Dept of Computer Science and Electrical Engineering, Luleå University of Technology.
    Instrument towards faster diagnosis and treatment of prostate cancer: Resonance sensor stiffness measurements on human prostate tissue in vitro2009Inngår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Heidelberg: Springer , 2009, 145-148 s.Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Prostate cancer is the most common cancer among men and the methods used to detect and diagnose prostate cancer are not sufficiently accurate. Radical prostatectomy is a surgical treatment of prostate cancer where the whole prostate is removed from the patient. Prostate tissue stiffness can be measured with a stiffness sensitive resonance sensor. The aim of this study was to measure the stiffness on the anterior and posterior side of fresh human prostate tissue in vitro and compare these two groups with each other and relate the findings with the prostate tissue histology.  In a prostate tissue slice with mostly normal healthy tissue, the anterior side was significantly harder (p-value < 0.05) as expected. In a prostate tissue slice with areas of cancer tumors, no difference was found between the anterior and posterior sides. However, large stiffness variations were found within groups with measurements points on cancer tissue (coefficient of variation, CV = 42 and 85%), as opposed to groups without cancer tissue (CV = 27 and 28%).  The large stiffness variations could be used as a sign for the presence of cancer. The results are promising for the development of an instrument and method for faster diagnosis on radical prostatectomy samples.

  • 44.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Andersson, Britt
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Lindahl, Olof
    Dept. of Computer Science and Electrical Engineering (Systemteknik), Luleå University of Technology.
    Stiffness of a small tissue phantom measured by a tactile resonance sensor2010Inngår i: IFMBE Proceedings of XII Mediterranean Conference on Medical and Biological Engineering and Computing, Heidelberg: Springer , 2010, 395-398 s.Konferansepaper (Fagfellevurdert)
  • 45.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Andersson, Britt M
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Bergh, Anders
    Umeå universitet, Medicinsk fakultet, Medicinsk biovetenskap.
    Ljungberg, Börje
    Umeå universitet, Medicinsk fakultet, Kirurgisk och perioperativ vetenskap.
    Lindahl, Olof
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Resonance sensor for prostate tissue stiffness measurements – detecting prostate cancer2006Inngår i: World Congress on Biomedical Engineering and Medical Physics, August 27 - September 1, 2006, Seoul, Korea, IFMBE , 2006Konferansepaper (Fagfellevurdert)
  • 46.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Andersson, Britt M
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Bergh, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Patologi.
    Ljungberg, Börje
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Urologi och andrologi.
    Lindahl, Olof A
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Explanatory models for a tactile resonance sensor system-elastic and density-related variations of prostate tissue in vitro2008Inngår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 29, nr 7, 729-745 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Tactile sensors based on piezoelectric resonance have been adopted for medical applications. The sensor consists of an oscillating piezoelectric sensor–circuit system, and a change in resonance frequency is observed when the sensor tip contacts a measured object such as tissue. The frequency change at a constant applied force or mass load is used as a stiffness-sensitive parameter in many applications. Differential relations between force and frequency have also been used for monitoring intraocular pressure and stiffness variations in prostate tissue in vitro. The aim of this study was to relate the frequency change (Δf), measured force (F) and the material properties, density and elasticity to an explanatory model for the resonance sensor measurement principle and thereby to give explanatory models for the stiffness parameters used previously. Simulations of theoretical equations were performed to investigate the relation between frequency change and contact impedance. Measurements with a resonance sensor system on prostate tissue in vitro were used for experimental validation of the theory. Tissue content was quantified with a microscopic-based morphometrical method. Simulation results showed that the frequency change was dependent upon density (ρ) and contact area (S) according to Δf ∝ ρS3/2. The experiments followed the simulated theory at small impression depths. The measured contact force followed a theoretical model with the dependence of the elastic modulus (E) and contact area, FES3/2. Measured density variations related to histological variations were statistically weak or non-significant. Elastic variations were statistically significant with contributions from stroma and cancer relative to normal glandular tissue. The theoretical models of frequency change and force were related through the contact area, and a material-dependent explanatory model was found as Δf ∝ ρE−1F. It explains the measurement principle and the previously established stiffness parameters from the material properties point of view.

  • 47.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Andersson, Britt M
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Bergh, Anders
    Umeå universitet, Medicinsk fakultet, Medicinsk biovetenskap.
    Ljungberg, Börje
    Umeå universitet, Medicinsk fakultet, Kirurgisk och perioperativ vetenskap.
    Lindahl, Olof A
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro.2006Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, Vol. 44, nr 7, 593-603 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Prostate cancer is the most common form of cancer in men in Europe and in the USA. Some prostate tumours are stiffer than the surrounding normal tissue, and it could therefore be of interest to measure prostate tissue stiffness. Resonance sensor technology based on piezoelectric resonance detects variations in tissue stiffness due to a change in the resonance frequency. An impression-controlled resonance sensor system was used to detect stiffness in silicone rubber and in human prostate tissue in vitro using two parameters, both combinations of frequency change and force. Variations in silicone rubber stiffness due to the mixing ratio of the two components could be detected (p<0.05) using both parameters. Measurements on prostate tissue showed that there existed a statistically significant (MANOVA test, p<0.001) reproducible difference between tumour tissue (n=13) and normal healthy tissue (n=98) when studying a multivariate parameter set. Both the tumour tissue and normal tissue groups had variations within them, which were assumed to be related to differences in tissue composition. Other sources of error could be uneven surfaces and different levels of dehydration for the prostates. Our results indicated that the resonance sensor could be used to detect stiffness variations in silicone and in human prostate tissue in vitro. This is promising for the development of a future diagnostic tool for prostate cancer.

  • 48.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Andersson, Britt M
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Bergh, Anders
    Umeå universitet, Medicinsk fakultet, Medicinsk biovetenskap.
    Ljungberg, Börje
    Umeå universitet, Medicinsk fakultet, Kirurgisk och perioperativ vetenskap.
    Lindahl, Olof A
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Resonance sensor measurements of stiffness variations in prostate tissue in vitro: a weighted tissue proportion model2006Inngår i: Physiological Measurement, ISSN 0967-3334, Vol. 27, nr 12, 1373-86 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Prostate cancer is the most common type of cancer in men in Europe and the US. The methods to detect prostate cancer are still precarious and new techniques are needed. A piezoelectric transducer element in a feedback system is set to vibrate with its resonance frequency. When the sensor element contacts an object a change in the resonance frequency is observed, and this feature has been utilized in sensor systems to describe physical properties of different objects. For medical applications it has been used to measure stiffness variations due to various patho-physiological conditions. In this study the sensor's ability to measure the stiffness of prostate tissue, from two excised prostatectomy specimens in vitro, was analysed. The specimens were also subjected to morphometric measurements, and the sensor parameter was compared with the morphology of the tissue with linear regression. In the probe impression interval 0.5-1.7 mm, the maximum R(2) > or = 0.60 (p < 0.05, n = 75). An increase in the proportion of prostate stones (corpora amylacea), stroma, or cancer in relation to healthy glandular tissue increased the measured stiffness. Cancer and stroma had the greatest effect on the measured stiffness. The deeper the sensor was pressed, the greater, i.e., deeper, volume it sensed. Tissue sections deeper in the tissue were assigned a lower mathematical weighting than sections closer to the sensor probe. It is concluded that cancer increases the measured stiffness as compared with healthy glandular tissue, but areas with predominantly stroma or many stones could be more difficult to differ from cancer.

  • 49.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Andersson, Britt M.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Bergh, Anders
    Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap.
    Ljungberg, Börje
    Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Urologi och andrologi.
    Lindahl, Olof A.
    Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
    Resonanssensorteknik för detektering av prostatacancer2010Inngår i: Medicinteknikdagarna 2010 / [ed] Ronnie Lundström, Umeå: Svensk förening för medicinsk teknik och fysik , 2010, 193-193 s.Konferansepaper (Fagfellevurdert)
  • 50.
    Jalkanen, Ville
    et al.
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Andersson, Britt M
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Bergh, Anders
    Umeå universitet, Medicinsk fakultet, Medicinsk biovetenskap.
    Ljungberg, Börje
    Umeå universitet, Medicinsk fakultet, Kirurgisk och perioperativ vetenskap.
    Lindahl, Olof A
    Umeå universitet, Teknisk-naturvetenskaplig fakultet, Tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskaplig fakultet, Centrum för medicinsk teknik och fysik.
    Spatial variations in prostate tissue histology as measured by a tactile resonance sensor2007Inngår i: Physiological Measurement, ISSN 0967-3334, Vol. 28, nr 10, 1267-81 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    In recent years, tactile sensors based on piezoelectric resonance sensor technology have been used for medical diagnosis where the sensor's stiffness-measuring properties can reflect tissue pathology. The change in the frequency of the resonating system and the change in force when contact is made with tissue are used as a stiffness parameter. Earlier stiffness measurements of prostate tissue in vitro demonstrate variations related to tissue composition. In this study, measured stiffness from two human prostate specimens was compared to histological composition of prostate tissue below and around the measurement points. Tissue stiffness was measured with the resonance sensor system. Tissue composition was measured at four different depths in the tissue specimen using a microscopic-image-based morphometrical method. With this method, the proportion of tissue types was determined at the points of intersections in a circular grid on the images representing each measurement point. Numerical values were used for weighting the tissue proportions at different depths in the tissue specimen. For an impression depth of 1.0 mm, the sensing depth in this study was estimated to be 3.5-5.5 mm. Stiffness variations due to horizontal tissue variations were investigated by studying the dependence of the size of the circular grid area relative to the contact area of the sensor tip. The sensing area (grid radius) was estimated to be larger than the contact area (contact radius) between the sensor tip and the tissue. Thus, the sensor tip registers spatial variations in prostate tissue histology, both directly below and lateral to the tip itself. These findings indicate that tumours around the sensor tip could be detected, which in turn supports the idea of a future resonance-sensor-based clinical device for detecting tumours and for guiding biopsies.

123 1 - 50 of 121
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf