Umeå University's logo

umu.sePublikasjoner
Endre søk
Link to record
Permanent link

Direct link
Rezaei-Pandar, Mohammad
Publikasjoner (2 av 2) Visa alla publikasjoner
Vardast, S., Muschet, A., Smijesh, N., Rezaei-Pandar, M., Schnur, F., Weissenbilder, R., . . . Veisz, L. (2026). High-intensity attosecond beamline for XUV pump–XUV probe measurements with photon energies up to 150 eV. APL Photonics, 11(5), Article ID 056115.
Åpne denne publikasjonen i ny fane eller vindu >>High-intensity attosecond beamline for XUV pump–XUV probe measurements with photon energies up to 150 eV
Vise andre…
2026 (engelsk)Inngår i: APL Photonics, E-ISSN 2378-0967, Vol. 11, nr 5, artikkel-id 056115Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The field of attosecond physics has expanded significantly in recent years, yet experimental facilities supporting attosecond pump–attosecond probe spectroscopy remain rare. Here, we present a newly constructed beamline for the generation and application of energetic, isolated extreme ultraviolet (XUV) and soft x-ray attosecond pulses via upscaling of high-harmonic generation (HHG) in a gas medium. The fundamental properties of the HHG radiation—energy, beam profile, spectrum, and divergence—are characterized and optimized. The source delivers up to 55 nJ of pulse energy within the Zr window (65–150 eV) with high stability (∼5%–10%) and a divergence of 0.1 mrad. Numerical simulations identify optimal operating conditions consistent with experimental results. Temporal super-resolution of the driving laser is applied, resulting in a broadened spectral continuum. Furthermore, the beamline includes a split-and-delay stage before focusing the HHG radiation to a < 6 μm spot for pump–probe experiments using two distinct focusing optics. Spatially resolved ion microscopy is employed to trace the generated ions at the focus. The presented beamline is designed for nonlinear XUV studies with isolated attosecond pulses.

sted, utgiver, år, opplag, sider
AIP Publishing, 2026
HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-254284 (URN)10.1063/5.0324877 (DOI)001777351800001 ()2-s2.0-105040179233 (Scopus ID)
Forskningsfinansiär
Swedish Research Council, 2017-04106Swedish Research Council, 2019-02376Swedish Research Council, 2020-05111Swedish Research Council, 2021-05992Swedish Research Council, 2023-04684Swedish Research Council, 2023-04603Knut and Alice Wallenberg Foundation, 2019.0140Knut and Alice Wallenberg Foundation, 2020.0111Knut and Alice Wallenberg Foundation, 2024.0120Knut and Alice Wallenberg Foundation, 2023.0207The Kempe Foundations, SMK21-0017The Kempe Foundations, JCSMK24-539
Tilgjengelig fra: 2026-06-15 Laget: 2026-06-15 Sist oppdatert: 2026-06-15bibliografisk kontrollert
Vardast, S., Muschet, A., Smijesh, N., Rezaei-Pandar, M., Schnur, F., Weissenbilder, R., . . . Veisz, L.High intensity attosecond beamline for XUV pump XUV probe measurements with photon energies up to 150 eV.
Åpne denne publikasjonen i ny fane eller vindu >>High intensity attosecond beamline for XUV pump XUV probe measurements with photon energies up to 150 eV
Vise andre…
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
Abstract [en]

The field of attosecond physics has expanded significantly in recent years, yet experimental facilities supporting attosecond pump attosecond probe spectroscopy remain rare. Here, we present a newly constructed beamline for the generation and application of energetic, isolated extreme ultraviolet (XUV) and soft X-ray attosecond pulses via upscaling of high-harmonic generation (HHG) in a gas medium. The fundamental properties of the HHG radiation energy, beam profile, spectrum, and divergence are characterized and optimized. The source delivers up to 55 nJ of pulse energy within the Zr window (65-150 eV) with high stability (~5-10) and a divergence of 0.1 mrad. Numerical simulations identify optimal operating conditions consistent with experimental results. Temporal super-resolution of the driving laser is applied, resulting in a broadened spectral continuum. Furthermore, the beamline includes a split-and-delay stage before focusing the HHG radiation to a <6 um spot for pump-probe experiments using two distinct focusing optics. Spatially resolved ion microscopy is employed to trace the generated ions at the focus. The presented beamline is designed for nonlinear XUV studies with attosecond isolated pulses.

HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-253291 (URN)10.48550/arXiv.2604.12602 (DOI)
Tilgjengelig fra: 2026-05-20 Laget: 2026-05-20 Sist oppdatert: 2026-05-20bibliografisk kontrollert
Organisasjoner