Umeå University's logo

umu.sePublikasjoner
Endre søk
Link to record
Permanent link

Direct link
Östlund, Fanny
Publikasjoner (3 av 3) Visa alla publikasjoner
Lindén, C., Qvarlander, S., Jóhannesson, G., Johansson, E., Östlund, F., Malm, J. & Eklund, A. (2018). Normal-Tension Glaucoma Has Normal Intracranial Pressure: A Prospective Study of Intracranial Pressure and Intraocular Pressure in Different Body Positions. Ophthalmology, 125(3), 361-368
Åpne denne publikasjonen i ny fane eller vindu >>Normal-Tension Glaucoma Has Normal Intracranial Pressure: A Prospective Study of Intracranial Pressure and Intraocular Pressure in Different Body Positions
Vise andre…
2018 (engelsk)Inngår i: Ophthalmology, ISSN 0161-6420, E-ISSN 1549-4713, Vol. 125, nr 3, s. 361-368Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

PURPOSE: To test the hypothesis that normal-tension glaucoma (NTG) is caused by an increased pressure difference across the lamina cribrosa (LC) related to a low intracranial pressure (ICP).

DESIGN: Prospective case-control study.

PARTICIPANTS: Thirteen NTG patients (9 women; median 71 [range: 56-83] years) were recruited for investigation with the same protocol as 11 healthy volunteers (8 women; 47 [30-59] years). A larger control group (n = 51; 30 women; 68 [30-81] years) was used only for ICP comparison in supine position.

METHODS: ICP and intraocular pressure (IOP) were simultaneously measured in supine, sitting, and 9° head-down tilt (HDT) positions. Trans-lamina cribrosa pressure difference (TLCPD) was calculated using ICP and IOP together with geometric distances estimated from magnetic resonance imaging to adjust for hydrostatic effects.

MAIN OUTCOME MEASURES: ICP, IOP, and TLCPD in different body positions.

RESULTS: Between NTG patients and healthy volunteers, there were no differences in ICP, IOP, or TLCPD in supine, sitting, or HDT (P ≥ 0.11), except for IOP in HDT (P = 0.04). There was no correlation between visual field defect and TLCPD, IOP, or ICP and in any body position (P ≥ 0.39). Mean ICP in supine was 10.3 mmHg (SD = 2.7) in the NTG group (n = 13) and 11.3 (2.2) mmHg in the larger control group (n = 51) (P = 0.24).

CONCLUSIONS: There was no evidence of reduced ICP in NTG patients as compared with healthy controls, either in supine or in upright position. Consequently, the hypothesis that NTG is caused by an elevated TLCPD from low ICP was not supported.

HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-142423 (URN)10.1016/j.ophtha.2017.09.022 (DOI)000425377300015 ()29096996 (PubMedID)2-s2.0-85032749489 (Scopus ID)
Forskningsfinansiär
Swedish Research Council, 2015-05616
Tilgjengelig fra: 2017-11-30 Laget: 2017-11-30 Sist oppdatert: 2024-01-15bibliografisk kontrollert
Lindén, C., Qvarlander, S., Jóhannesson, G., Johansson, E., Östlund, F., Malm, J. & Eklund, A. (2018). Re: Linden et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368) REPLY [Letter to the editor]. Ophthalmology, 125(6), e43-e44
Åpne denne publikasjonen i ny fane eller vindu >>Re: Linden et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368) REPLY
Vise andre…
2018 (engelsk)Inngår i: Ophthalmology, ISSN 0161-6420, E-ISSN 1549-4713, Vol. 125, nr 6, s. e43-e44Artikkel i tidsskrift, Letter (Fagfellevurdert) Published
sted, utgiver, år, opplag, sider
Elsevier, 2018
HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-148825 (URN)10.1016/j.ophtha.2018.01.006 (DOI)000432371600007 ()29784104 (PubMedID)
Merknad

Refers to: Baartman B, Sudhagoni R, Swan R, Greenwood M, Berdahl, J. Re: Linden et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368) DOI: 10.1016/j.ophtha.2017.09.022

Tilgjengelig fra: 2018-06-21 Laget: 2018-06-21 Sist oppdatert: 2024-01-15bibliografisk kontrollert
Lindén, C., Qvarlander, S., Jóhannesson, G., Johansson, E., Östlund, F., Malm, J. & Eklund, A. (2018). Re: Lindén et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology.2018;125:361-368) REPLY [Letter to the editor]. Ophthalmology, 125(10), e74-e75
Åpne denne publikasjonen i ny fane eller vindu >>Re: Lindén et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology.2018;125:361-368) REPLY
Vise andre…
2018 (engelsk)Inngår i: Ophthalmology, ISSN 0161-6420, E-ISSN 1549-4713, Vol. 125, nr 10, s. e74-e75Artikkel i tidsskrift, Letter (Fagfellevurdert) Published
sted, utgiver, år, opplag, sider
Elsevier, 2018
HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-213190 (URN)10.1016/j.ophtha.2018.04.028 (DOI)000445012100008 ()30243346 (PubMedID)2-s2.0-85053288788 (Scopus ID)
Merknad

Refers to: Re: Lindén et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368)Ophthalmology, Volume 125, Issue 10, October 2018, Pages e74Xiangxiang Liu, Diya Yang, Yiquan Yang, Hanruo Liu, Xiaoxia Li, Yuan Xie, Ningli Wang. DOI: 10.1016/j.ophtha.2018.04.027

Tilgjengelig fra: 2023-08-22 Laget: 2023-08-22 Sist oppdatert: 2024-01-15bibliografisk kontrollert
Organisasjoner