Umeå universitets logga

umu.sePublikationer
Ändra sökning
Länk till posten
Permanent länk

Direktlänk
Östlund, Fanny
Publikationer (3 of 3) Visa alla publikationer
Lindén, C., Qvarlander, S., Jóhannesson, G., Johansson, E., Östlund, F., Malm, J. & Eklund, A. (2018). Normal-Tension Glaucoma Has Normal Intracranial Pressure: A Prospective Study of Intracranial Pressure and Intraocular Pressure in Different Body Positions. Ophthalmology, 125(3), 361-368
Öppna denna publikation i ny flik eller fönster >>Normal-Tension Glaucoma Has Normal Intracranial Pressure: A Prospective Study of Intracranial Pressure and Intraocular Pressure in Different Body Positions
Visa övriga...
2018 (Engelska)Ingår i: Ophthalmology, ISSN 0161-6420, E-ISSN 1549-4713, Vol. 125, nr 3, s. 361-368Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: To test the hypothesis that normal-tension glaucoma (NTG) is caused by an increased pressure difference across the lamina cribrosa (LC) related to a low intracranial pressure (ICP).

DESIGN: Prospective case-control study.

PARTICIPANTS: Thirteen NTG patients (9 women; median 71 [range: 56-83] years) were recruited for investigation with the same protocol as 11 healthy volunteers (8 women; 47 [30-59] years). A larger control group (n = 51; 30 women; 68 [30-81] years) was used only for ICP comparison in supine position.

METHODS: ICP and intraocular pressure (IOP) were simultaneously measured in supine, sitting, and 9° head-down tilt (HDT) positions. Trans-lamina cribrosa pressure difference (TLCPD) was calculated using ICP and IOP together with geometric distances estimated from magnetic resonance imaging to adjust for hydrostatic effects.

MAIN OUTCOME MEASURES: ICP, IOP, and TLCPD in different body positions.

RESULTS: Between NTG patients and healthy volunteers, there were no differences in ICP, IOP, or TLCPD in supine, sitting, or HDT (P ≥ 0.11), except for IOP in HDT (P = 0.04). There was no correlation between visual field defect and TLCPD, IOP, or ICP and in any body position (P ≥ 0.39). Mean ICP in supine was 10.3 mmHg (SD = 2.7) in the NTG group (n = 13) and 11.3 (2.2) mmHg in the larger control group (n = 51) (P = 0.24).

CONCLUSIONS: There was no evidence of reduced ICP in NTG patients as compared with healthy controls, either in supine or in upright position. Consequently, the hypothesis that NTG is caused by an elevated TLCPD from low ICP was not supported.

Nationell ämneskategori
Oftalmologi
Identifikatorer
urn:nbn:se:umu:diva-142423 (URN)10.1016/j.ophtha.2017.09.022 (DOI)000425377300015 ()29096996 (PubMedID)2-s2.0-85032749489 (Scopus ID)
Forskningsfinansiär
Vetenskapsrådet, 2015-05616
Tillgänglig från: 2017-11-30 Skapad: 2017-11-30 Senast uppdaterad: 2024-01-15Bibliografiskt granskad
Lindén, C., Qvarlander, S., Jóhannesson, G., Johansson, E., Östlund, F., Malm, J. & Eklund, A. (2018). Re: Linden et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368) REPLY [Letter to the editor]. Ophthalmology, 125(6), e43-e44
Öppna denna publikation i ny flik eller fönster >>Re: Linden et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368) REPLY
Visa övriga...
2018 (Engelska)Ingår i: Ophthalmology, ISSN 0161-6420, E-ISSN 1549-4713, Vol. 125, nr 6, s. e43-e44Artikel i tidskrift, Letter (Refereegranskat) Published
Ort, förlag, år, upplaga, sidor
Elsevier, 2018
Nationell ämneskategori
Oftalmologi
Identifikatorer
urn:nbn:se:umu:diva-148825 (URN)10.1016/j.ophtha.2018.01.006 (DOI)000432371600007 ()29784104 (PubMedID)
Anmärkning

Refers to: Baartman B, Sudhagoni R, Swan R, Greenwood M, Berdahl, J. Re: Linden et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368) DOI: 10.1016/j.ophtha.2017.09.022

Tillgänglig från: 2018-06-21 Skapad: 2018-06-21 Senast uppdaterad: 2024-01-15Bibliografiskt granskad
Lindén, C., Qvarlander, S., Jóhannesson, G., Johansson, E., Östlund, F., Malm, J. & Eklund, A. (2018). Re: Lindén et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology.2018;125:361-368) REPLY [Letter to the editor]. Ophthalmology, 125(10), e74-e75
Öppna denna publikation i ny flik eller fönster >>Re: Lindén et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology.2018;125:361-368) REPLY
Visa övriga...
2018 (Engelska)Ingår i: Ophthalmology, ISSN 0161-6420, E-ISSN 1549-4713, Vol. 125, nr 10, s. e74-e75Artikel i tidskrift, Letter (Refereegranskat) Published
Ort, förlag, år, upplaga, sidor
Elsevier, 2018
Nationell ämneskategori
Oftalmologi
Identifikatorer
urn:nbn:se:umu:diva-213190 (URN)10.1016/j.ophtha.2018.04.028 (DOI)000445012100008 ()30243346 (PubMedID)2-s2.0-85053288788 (Scopus ID)
Anmärkning

Refers to: Re: Lindén et al.: Normal-tension glaucoma has normal intracranial pressure: a prospective study of intracranial pressure and intraocular pressure in different body positions (Ophthalmology. 2018;125:361-368)Ophthalmology, Volume 125, Issue 10, October 2018, Pages e74Xiangxiang Liu, Diya Yang, Yiquan Yang, Hanruo Liu, Xiaoxia Li, Yuan Xie, Ningli Wang. DOI: 10.1016/j.ophtha.2018.04.027

Tillgänglig från: 2023-08-22 Skapad: 2023-08-22 Senast uppdaterad: 2024-01-15Bibliografiskt granskad
Organisationer

Sök vidare i DiVA

Visa alla publikationer