Umeå University's logo

umu.sePublications
Change search
Link to record
Permanent link

Direct link
Publications (10 of 12) Show all publications
Zhao, G., Hausmaninger, T., Schmidt, F. M., Ma, W. & Axner, O. (2019). High-resolution trace gas detection by sub-Doppler noise-immune cavity-enhanced optical heterodyne molecular spectrometry: application to detection of acetylene in human breath. Optics Express, 27(13), 17940-17953
Open this publication in new window or tab >>High-resolution trace gas detection by sub-Doppler noise-immune cavity-enhanced optical heterodyne molecular spectrometry: application to detection of acetylene in human breath
Show others...
2019 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 27, no 13, p. 17940-17953Article in journal (Refereed) Published
Abstract [en]

A sensitive high-resolution sub-Doppler detecting spectrometer, based on noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS), for trace gas detection of species whose transitions have severe spectral overlap with abundant concomitant species is presented. It is designed around a NICE-OHMS instrumentation utilizing balanced detection that provides shot-noise limited Doppler-broadened (Db) detection. By synchronous dithering the positions of the two cavity mirrors, the effect of residual etalons between the cavity and other surfaces in the system could be reduced. An Allan deviation of the absorption coefficient of 2.2 × 10-13 cm-1 at 60 s, which, for the targeted transition in C2H2, corresponds to a 3σ detection sensitivity of 130 ppt, is demonstrated. It is shown that despite significant spectral interference from CO2 at the targeted transition, which precludes Db detection of C2H2, acetylene could be detected in exhaled breath of healthy smokers.

Place, publisher, year, edition, pages
Optical Society of America, 2019
National Category
Atom and Molecular Physics and Optics Physical Chemistry Medical Engineering
Identifiers
urn:nbn:se:umu:diva-161422 (URN)10.1364/OE.27.017940 (DOI)000472621000043 ()31252745 (PubMedID)2-s2.0-85068037731 (Scopus ID)
Projects
Bio4Energy
Funder
Swedish Research Council, 2015-04374Swedish Research Council, 2013-6031The Kempe Foundations, JCK-1317The Kempe Foundations, SMK-1446Bio4Energy
Available from: 2019-07-07 Created: 2019-07-07 Last updated: 2023-03-23Bibliographically approved
Johansson, A. C., Rutkowski, L., Maslowski, P., Filipsson, A., Hausmaninger, T., Zhao, G., . . . Foltynowicz, A. (2019). Precise comb-based fourier transform spectroscopy for line parameter retrieval. In: 2019 Conference on Lasers and Electro-Optics Europe and European Quantum Electronics Conference (CLEO/EUROPE-EQEC): . Paper presented at Conference on Lasers and Electro-Optics Europe / European Quantum Electronics Conference (CLEO/Europe-EQEC), Munich, GERMANY, JUN 23-27, 2019.. Institute of Electrical and Electronics Engineers (IEEE), Article ID 8872655.
Open this publication in new window or tab >>Precise comb-based fourier transform spectroscopy for line parameter retrieval
Show others...
2019 (English)In: 2019 Conference on Lasers and Electro-Optics Europe and European Quantum Electronics Conference (CLEO/EUROPE-EQEC), Institute of Electrical and Electronics Engineers (IEEE), 2019, article id 8872655Conference paper, Published paper (Refereed)
Abstract [en]

Accurate parameters of molecular transitions are needed for data analysis in many applications, ranging from atmospheric research to astrophysics and determination of fundamental constants. Optical frequency comb Fourier transform spectroscopy (OFC-FTS) is particularly well-suited for high-precision measurements of broadband molecular spectra. From these spectra, the parameters of individual transitions - all measured simultaneously under the same experimental conditions - can be determined. We use a mechanical OFC-FTS spectrometer with sub-nominal resolution [1, 2] to perform precise broadband measurements of entire molecular bands of CO2 using either direct absorption spectroscopy or cavity-enhanced complex refractive index spectroscopy (CE-CRIS) [3] and we extract line parameters for line shapes beyond the Voigt profile.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2019
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-187341 (URN)10.1109/CLEOE-EQEC.2019.8872655 (DOI)000630002700957 ()2-s2.0-85074627170 (Scopus ID)978-1-7281-0469-0 (ISBN)
Conference
Conference on Lasers and Electro-Optics Europe / European Quantum Electronics Conference (CLEO/Europe-EQEC), Munich, GERMANY, JUN 23-27, 2019.
Available from: 2021-09-13 Created: 2021-09-13 Last updated: 2023-08-28Bibliographically approved
Johansson, A. C., Rutkowski, L., Filipsson, A., Hausmaninger, T., Zhao, G., Axner, O. & Foltynowicz, A. (2018). Broadband calibration-free cavity-enhanced complex refractive index spectroscopy using a frequency comb. Optics Express, 26(16), 20633-20648
Open this publication in new window or tab >>Broadband calibration-free cavity-enhanced complex refractive index spectroscopy using a frequency comb
Show others...
2018 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 26, no 16, p. 20633-20648Article in journal (Refereed) Published
Abstract [en]

We present broadband cavity-enhanced complex refractive index spectroscopy (CE-CRIS), a technique for calibration-free determination of the complex refractive index of entire molecular bands via direct measurement of transmission modes of a Fabry-Perot cavity filled with the sample. The measurement of the cavity transmission spectrum is done using an optical frequency comb and a mechanical Fourier transform spectrometer with sub-nominal resolution. Molecular absorption and dispersion spectra (corresponding to the imaginary and real parts of the refractive index) are obtained from the cavity mode broadening and shift retrieved from fits of Lorentzian profiles to the individual cavity modes. This method is calibration-free because the mode broadening and shift are independent of the cavity parameters such as the length and mirror reflectivity. In this first demonstration of broadband CE-CRIS we measure simultaneously the absorption and dispersion spectra of three combination bands of CO2 in the range between 1525 nm and 1620 nm and achieve good agreement with theoretical models. This opens up for precision spectroscopy of the complex refractive index of several molecular bands simultaneously. 

Place, publisher, year, edition, pages
Optical Society of America, 2018
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-151397 (URN)10.1364/OE.26.020633 (DOI)000440803600079 ()30119372 (PubMedID)2-s2.0-85051244198 (Scopus ID)
Funder
Swedish Research Council, 2016-03593Swedish Research Council, 2015-04374Knut and Alice Wallenberg Foundation, KAW 2015.0159
Available from: 2018-09-04 Created: 2018-09-04 Last updated: 2023-03-23Bibliographically approved
Johansson, A. C., Rutkowski, L., Filipsson, A., Hausmaninger, T., Zhao, G., Axner, O. & Foltynowicz, A. (2018). Broadband Complex Refractive Index Spectroscopy via Measurement of Cavity Modes. In: 2018 Conference on Lasers and Electro-Optics (CLEO): . Paper presented at Conference on Lasers and Electro-Optics (CLEO), May 13-18, 2018, San Jose, CA, United States. IEEE
Open this publication in new window or tab >>Broadband Complex Refractive Index Spectroscopy via Measurement of Cavity Modes
Show others...
2018 (English)In: 2018 Conference on Lasers and Electro-Optics (CLEO), IEEE, 2018Conference paper (Refereed)
Abstract [en]

We retrieve high precision absorption and dispersion spectra of the 3v(1)+v(3) band of CO2 from direct measurement of cavity transmission modes using an optical frequency comb and a mechanical Fourier transfolin spectrometer with sub-nominal resolution.

Place, publisher, year, edition, pages
IEEE, 2018
Series
Conference on Lasers and Electro-Optics, ISSN 2160-9020
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-174239 (URN)10.1364/CLEO_SI.2018.STu3P.4 (DOI)000526031003272 ()2-s2.0-85048952198 (Scopus ID)978-1-9435-8042-2 (ISBN)
Conference
Conference on Lasers and Electro-Optics (CLEO), May 13-18, 2018, San Jose, CA, United States
Note

Paper STu3P.4

Available from: 2020-08-19 Created: 2020-08-19 Last updated: 2023-03-24Bibliographically approved
Johansson, A. C., Rutkowski, L., Filipsson, A., Hausmaninger, T., Zhao, G., Axner, O. & Foltynowicz, A. (2018). Cavity-enhanced complex refractive index spectroscopy of entire molecular bands using a frequency comb. In: Optics InfoBase Conference Papers: . Paper presented at Fourier Transform Spectroscopy, FTS 2018, 5–8 November, 2018, Singapore, Singapore. Optica Publishing Group, Article ID JT2A.29.
Open this publication in new window or tab >>Cavity-enhanced complex refractive index spectroscopy of entire molecular bands using a frequency comb
Show others...
2018 (English)In: Optics InfoBase Conference Papers, Optica Publishing Group , 2018, article id JT2A.29Conference paper, Published paper (Refereed)
Abstract [en]

We demonstrate broadband calibration-free complex refractive index spectroscopy of entire molecular bands by direct measurement of transmission modes of a Fabry-Perot cavity using frequency comb-based Fourier transform spectrometer with sub-nominal resolution.

Place, publisher, year, edition, pages
Optica Publishing Group, 2018
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-203021 (URN)10.1364/FTS.2018.JT2A.29 (DOI)2-s2.0-85059542397 (Scopus ID)9781943580477 (ISBN)
Conference
Fourier Transform Spectroscopy, FTS 2018, 5–8 November, 2018, Singapore, Singapore
Available from: 2023-01-16 Created: 2023-01-16 Last updated: 2023-03-24Bibliographically approved
Hausmaninger, T., Zhao, G., Ma, W. & Axner, O. (2018). Depletion of the vibrational ground state of CH4 in absorption spectroscopy at 3.4 μm in N2 and air in the 1-100Torr range. Journal of Quantitative Spectroscopy and Radiative Transfer, 205, 59-70
Open this publication in new window or tab >>Depletion of the vibrational ground state of CH4 in absorption spectroscopy at 3.4 μm in N2 and air in the 1-100Torr range
2018 (English)In: Journal of Quantitative Spectroscopy and Radiative Transfer, ISSN 0022-4073, E-ISSN 1879-1352, Vol. 205, p. 59-70Article in journal (Refereed) Published
Abstract [en]

A model presented in an accompanying work predicts that mid-IR absorption signals from methane in trace concentrations in various buffer gases detected at pressures in the 1-100Torr range can be reduced and distorted due to depletion of the vibrational ground state if the molecules are exposed to laser powers in the tens of mW range or above. This work provides experimental evidence of such depletion in a resonant cavity under a variety of conditions, e.g. for intracavity laser powers up to 2W and for buffer gases of N-2 or dry air, and verifies the applicability of the model. It was found that the degree of depletion is significantly larger in N-2 than dry air, and that it increases with pressure for pressures up to around 10Torr (attributed to a decreased diffusion rate) but decreases with pressure for pressures above 20Torr (caused by an increased collisional vibrational decay rate). The maximum degree of depletion (similar to 80%) was obtained for methane in N-2 at around 15Torr. This implies that absorption spectrometry of methane can experience significant non-linear dependencies on laser power, pressure, as well as buffer gas composition. It is shown that depletion takes place also in (CH4)-C-13, which verifies the applicability of the model also for this isotopologue, and that NICE-OHMS signals detected in absorption phase are less affected by depletion than in dispersion. It was concluded that the absorption mode of detection can provide concentration assessments that are virtually free of influence of depletion for intracavity powers below 0.8 W. 

Place, publisher, year, edition, pages
PERGAMON-ELSEVIER SCIENCE LTD, 2018
Keywords
Absorption spectroscopy, Cavity enhanced, Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy, Methane, Depletion, Optical saturation
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-143714 (URN)10.1016/j.jqsrt.2017.10.007 (DOI)000417665000008 ()2-s2.0-85033558806 (Scopus ID)
Available from: 2018-01-08 Created: 2018-01-08 Last updated: 2023-03-24Bibliographically approved
Zhao, G., Hausmaninger, T., Ma, W. & Axner, O. (2018). Shot-noise-limited Doppler-broadened noise-immune cavity-enhanced optical heterodyne molecular spectrometry. Optics Letters, 43(4), 715-718
Open this publication in new window or tab >>Shot-noise-limited Doppler-broadened noise-immune cavity-enhanced optical heterodyne molecular spectrometry
2018 (English)In: Optics Letters, ISSN 0146-9592, E-ISSN 1539-4794, Vol. 43, no 4, p. 715-718Article in journal (Refereed) Published
Abstract [en]

Shot-noise-limited Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) has been realized by implementation of balanced detection. A characterization of the system based on Allan-Werle plots of the absorption coefficient, retrieved by fitting a model function to data, shows that the system has a white noise equivalent absorption per unit length per square root of bandwidth of 2.3 x 10(-13) cm(-1) Hz(-1/2), solely 44% above the shot noise limit, and a detection sensitivity of 2.2 x 10(-14) cm(-1) over 200 s, both being unprecedented for Db NICE-OHMS. The white noise response follows the expected inverse square root dependence on power that is representative of a shot-noise-limited response, which confirms that the system is shot-noise-limited. 

National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-145590 (URN)10.1364/OL.43.000715 (DOI)000425123700023 ()29444060 (PubMedID)2-s2.0-85042053622 (Scopus ID)
Funder
Swedish Research Council, 2015-04374
Available from: 2018-03-21 Created: 2018-03-21 Last updated: 2023-03-23Bibliographically approved
Zhao, G., Hausmaninger, T., Ma, W. & Axner, O. (2017). Differential noise-immune cavity-enhanced optical heterodyne molecular spectroscopy for improvement of the detection sensitivity by reduction of drifts from background signals. Optics Express, 25(23), 29454-29471
Open this publication in new window or tab >>Differential noise-immune cavity-enhanced optical heterodyne molecular spectroscopy for improvement of the detection sensitivity by reduction of drifts from background signals
2017 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 25, no 23, p. 29454-29471Article in journal (Refereed) Published
Abstract [en]

The detection sensitivity of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) is often limited by background signals that bring in drifts. A novel realization of NICE-OHMS, termed differential NICE-OHMS, that both reduces such drifts and enlarges the molecular signal is presented. It is based on simultaneous detection of NICE-OHMS signals in reflection and transmission, followed by a subtraction of the former (properly weighted) from the latter. An Allan plot analysis shows that the instrumentation could demonstrate a noise equivalent absorption per unit length (NEAL) of 4.7 × 10−14 cm−1, obtained for an integration time of 170 s.

Place, publisher, year, edition, pages
Optical Society of America, 2017
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-142459 (URN)10.1364/OE.25.029454 (DOI)000415136700127 ()2-s2.0-85033585268 (Scopus ID)
Available from: 2017-12-04 Created: 2017-12-04 Last updated: 2023-03-24Bibliographically approved
Rutkowski, L., Johansson, A. C., Zhao, G., Hausmaninger, T., Khodabakhsh, A., Axner, O. & Foltynowicz, A. (2017). Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution. Optics Express, 25(18), 21711-21718
Open this publication in new window or tab >>Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution
Show others...
2017 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 25, no 18, p. 21711-21718Article in journal (Refereed) Published
Abstract [en]

Optical cavities provide high sensitivity to dispersion since their resonance frequencies depend on the index of refraction. We present a direct, broadband, and accurate measurement of the modes of a high finesse cavity using an optical frequency comb and a mechanical Fourier transform spectrometer with a kHz-level resolution. We characterize 16000 longitudinal cavity modes spanning 16 THz of bandwidth in terms of center frequency, linewidth, and amplitude. Using the center frequencies we retrieve the group delay dispersion of the cavity mirror coatings and pure N2 with 0.1 fs2 precision and 1 fs2 accuracy, as well as the refractivity of the 3ν13 absorption band of CO2 with 5 × 10‒12 precision. This opens up for broadband refractive index metrology and calibration-free spectroscopy of entire molecular bands.

Place, publisher, year, edition, pages
Optical Society of America, 2017
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-140651 (URN)10.1364/OE.25.021711 (DOI)000411529000067 ()2-s2.0-85029217998 (Scopus ID)
Note

Errata: Lucile Rutkowski, Alexandra C. Johansson, Gang Zhao, Thomas Hausmaninger, Amir Khodabakhsh, Ove Axner, and Aleksandra Foltynowicz, "Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution: erratum," Opt. Express 28, 13290-13291 (2020). DOI: 10.1364/OE.392937

Available from: 2017-10-17 Created: 2017-10-17 Last updated: 2023-03-24Bibliographically approved
Zhao, G., Hausmaninger, T., Ma, W. & Axner, O. (2017). Whispering-gallery-mode laser-based noise-immune cavity-enhanced optical heterodyne molecular spectrometry. Optics Letters, 42(16), 3109-3112
Open this publication in new window or tab >>Whispering-gallery-mode laser-based noise-immune cavity-enhanced optical heterodyne molecular spectrometry
2017 (English)In: Optics Letters, ISSN 0146-9592, E-ISSN 1539-4794, Vol. 42, no 16, p. 3109-3112Article in journal (Refereed) Published
Abstract [en]

The whispering-gallery-mode (WGM) laser is a type of laser that has an exceptionally narrow linewidth. Noise-immune cavity-enhanced optical heterodyne molecular spectrometry, which is a detection technique with extraordinary properties that benefit from narrow linewidth lasers, has been realized with a WGM laser. By locking to a cavity with a finesse of 55 000, acetylene and carbon dioxide could be simultaneously detected down to an unprecedented noise equivalent absorption per unit length of 6.6 x 10(-14) cm(-1) over 150 s, corresponding to 5 ppt of C2H2.

Place, publisher, year, edition, pages
OPTICAL SOC AMER, 2017
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:umu:diva-142879 (URN)10.1364/OL.42.003109 (DOI)000407640000014 ()28809884 (PubMedID)2-s2.0-85027510589 (Scopus ID)
Available from: 2017-12-13 Created: 2017-12-13 Last updated: 2023-03-23Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0002-3966-8943

Search in DiVA

Show all publications