Optimal contrast as a function of noise for Butterworth filtering of 111 In-pentetreotide SPECT when using model-based compensation
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Vise andre og tillknytning
2013 (engelsk)Inngår i: 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

In 111 In-pentetreotide SPECT, it can be difficult to detect small tumors because of low spatial resolution and high noise levels. For an efficient cancer treatment, it is however important to detect the tumors at an early stage. The aim of this study was to perform optimization of Butterworth post-filtering of In-111-pentetreotide SPECT, with regard to small tumor detection in the liver. All images were reconstructed with model-based OSEM reconstruction. Two collimators are evaluated, the extended low-energy general-purpose (ELEGP) and the medium-energy general-purpose (MEGP) collimator. The raw-data projection images are produced using Monte Carlo simulations of an anthropomorphic phantom with realistic In-111-pentetreotide uptake, including seven spherical tumors in the liver. Evaluation was performed using tumor contrast as a function of background noise. According to the results, the detection of the smallest tumors is facilitated by not applying a filter. For somewhat larger tumors, a Butterworth filter of critical frequencies of 0.5-0.6 cm(-1) and an order of 10-12 is more appropriate. ELEGP proved to be better than MEGP for small tumor detection. The study is a continuation of a previous project where collimator choice, acquisition time, number of projection angles and OSEM settings were studied for the same geometry.

sted, utgiver, år, opplag, sider
2013.
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-129851DOI: 10.1109/NSSMIC.2013.6829275ISI: 000347163501089Scopus ID: 2-s2.0-84904166100ISBN: 978-1-4799-0534-8 (tryckt)OAI: oai:DiVA.org:umu-129851DiVA, id: diva2:1063474
Konferanse
60th IEEE Nuclear Science Symposium (NSS) / Medical Imaging Conference (MIC) / 20th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, OCT 27-NOV 02, 2013, Seoul, SOUTH KOREA
Tilgjengelig fra: 2017-01-10 Laget: 2017-01-09 Sist oppdatert: 2023-03-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Larsson, AnneSundström, TorbjörnAxelsson, JanRiklund, Katrine

Søk i DiVA

Av forfatter/redaktør
Larsson, AnneSundström, TorbjörnAxelsson, JanRiklund, Katrine
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 405 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf