Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Methods for counting residual leukocytes in leukocyte-depleted plasma-a comparison between a routine hematology instrument, the Nageotte chamber, flow cytometry, and a fluorescent microscopy analyzer
Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Klinisk kemi.
2017 (engelsk)Inngår i: Transfusion, ISSN 0041-1132, E-ISSN 1537-2995, Vol. 57, nr 5, s. 1192-1198Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Counting very low levels of leukocytes is technically challenging but mandatory for quality control of leukocyte-depleted plasma. Established assays, such as flow cytometry and counting in the Nageotte chamber, are laborious and expensive. The aim of this study was to test two alternative assays, the cerebrospinal fluid program in the routine hematology analyzer ADVIA 2120 and a fluorescence microscopy analyzer, the ADAM-rWBC. STUDY DESIGN AND METHODS: Linearity, accuracy, and precision were established for the ADVIA 2120, the ADAM-rWBC analyzer and the Nageotte chamber with flow cytometry as the reference method. Two hundred consecutive leukocyte-depleted donor plasma samples were also tested. RESULTS: The ADAM-rWBC analyzer and the Nageotte chamber fulfilled all quality requirements. Flow cytometry fulfilled the requirements for linearity and precision. The ADVIA 2120 analyzer did not fully reach the quality criteria, and flow cytometry did not reach quality criteria on accuracy. No false-positive results on donor plasma samples were recorded. CONCLUSION: The ADAM-rWBC is suitable for the purpose of quality control of residual leukocytes in leukocyte-depleted plasma. For the ADVIA 2120, further improvements and studies are needed to reach the quality requirements stated in this study.

sted, utgiver, år, opplag, sider
WILEY , 2017. Vol. 57, nr 5, s. 1192-1198
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-137006DOI: 10.1111/trf.14007ISI: 000402875300015PubMedID: 28130849Scopus ID: 2-s2.0-85010931791OAI: oai:DiVA.org:umu-137006DiVA, id: diva2:1117738
Tilgjengelig fra: 2017-06-29 Laget: 2017-06-29 Sist oppdatert: 2023-03-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Ekblom, Kim

Søk i DiVA

Av forfatter/redaktør
Ekblom, Kim
Av organisasjonen
I samme tidsskrift
Transfusion

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 329 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf