Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of a new cemented highly cross-linked all-polyethylene cup: a prospective and randomised study assessing wear and fixation characteristics using radiostereometric analysis
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Ortopedi.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Ortopedi.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Ortopedi.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Ortopedi.
Vise andre og tillknytning
2022 (engelsk)Inngår i: HIP International, ISSN 1120-7000, E-ISSN 1724-6067, Vol. 32, nr 6, s. 779-786Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND AND PURPOSE: The aim of this prospective, randomised and controlled study was to evaluate the wear and fixation properties of a new cemented highly cross-linked all-polyethylene (HXLPE) cup in comparison with a conventional cemented ultra-high molecular weight polyethylene (ConvPE) cup using radiostereometric analysis (RSA).

PATIENTS AND METHODS: A total of 58 patients (58 hips) with primary osteoarthritis (OA) were enrolled in a randomised controlled trial to receive either a ConvPE cup (control) or HXLPE cup (intervention) with identical geometry. The subjects were randomised in a 1:1 ratio. The primary endpoint was proximal wear measured as femoral head penetration into the cup, secondary outcomes were 3D-wear and annual proximal wear from 1 to 5 years. Cup fixation was measured as movement of the cup in relation to the acetabular bone with proximal migration being the primary outcome measure, 3D-migration and change in inclination as secondary outcomes. The patients were followed for 5 years with RSA performed postoperatively, at 3, 12, 24, and 60 months.

RESULTS: The HXLPE displayed a lower median proximal femoral head penetration compared to ConvPE, with a median difference at 2 years of -0.07 mm (95% CI, -0.10 to -0.04 mm), and -0.19 mm (95% CI, -0.27 to -0.15 mm) at 5 years. Annual proximal wear between 1 and 5 years was 0.03 mm/year for HXLPE and 0.06 mm/year for ConvPE (mean difference 0.05 mm, [95% CI, 0.03-0.07 mm]). Proximal migration, 3D migration and change in inclination was numerically slightly higher for HXLPE, albeit not statistically significant.

CONCLUSIONS: Compared to ConvPE, the HXLPE cup displayed significantly lower polyethylene wear. Cup migration was not statistically significant different.

CLINICALTRIALS.GOV IDENTIFIER: NCT04322799.

sted, utgiver, år, opplag, sider
Sage Publications, 2022. Vol. 32, nr 6, s. 779-786
Emneord [en]
Highly cross-linked polyethylene, RCT, RSA, migration, wear
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-180299DOI: 10.1177/1120700021989991ISI: 000631213800001PubMedID: 33566703Scopus ID: 2-s2.0-85101002186OAI: oai:DiVA.org:umu-180299DiVA, id: diva2:1528794
Tilgjengelig fra: 2021-02-16 Laget: 2021-02-16 Sist oppdatert: 2024-07-02bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Otten, VolkerMukka, SebastianCrnalic, SeadNilsson, Kjell G.

Søk i DiVA

Av forfatter/redaktør
Otten, VolkerMukka, SebastianCrnalic, SeadNilsson, Kjell G.
Av organisasjonen
I samme tidsskrift
HIP International

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 432 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf