Comparison between two mobile applications measuring shoulder elevation angle–A validity and feasibility study
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0003-3363-7414
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Vise andre og tillknytning
2021 (engelsk)Inngår i: Medical Engineering and Physics, ISSN 1350-4533, E-ISSN 1873-4030, Vol. 98, s. 1-7Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Pain in the shoulder complex affects the working population where work with elevated arms is a risk factor. The aim of the present study was to compare a mobile application for measurements of arm elevation, ErgoExposure, against an existing mobile application, ErgoArmMeter, in a laboratory setting and to test the feasibility in a field trial. Eleven persons performed three tasks in the laboratory setting: static, dynamic, and simulated work tasks, where the applications were validated against an optical tracking system (OTS). Also, ErgoExposure was tested by a teacher in a real-world situation. Limits of agreement for the static task varied between -6.1° to 4.2° (ErgoExposure) and between -7.6° to 5.2° (ErgoArmMeter). The average root mean square difference for dynamic and simulated work tasks was 3.4° (ErgoExposure) and 7.7° (ErgoArmMeter). From the field trial, different work tasks produced distinct exposure variation analysis patterns. Both apps showed similar results compared to OTS, but ErgoExposure was more accurate than ErgoArmMeter.

sted, utgiver, år, opplag, sider
Elsevier, 2021. Vol. 98, s. 1-7
Emneord [en]
Biomechanics, Ergonomics, Mobile phone
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-188862DOI: 10.1016/j.medengphy.2021.10.005ISI: 000712268000001PubMedID: 34848028Scopus ID: 2-s2.0-85117245488OAI: oai:DiVA.org:umu-188862DiVA, id: diva2:1607981
Tilgjengelig fra: 2021-11-02 Laget: 2021-11-02 Sist oppdatert: 2023-03-24bibliografisk kontrollert

Open Access i DiVA

fulltext(1864 kB)146 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1864 kBChecksum SHA-512
c1cd43e960771e613a3b5b804a873d63066c1b45045a952558e89c1745cfd6a83f6fb8cdbb49e12c5051c3d4845ab208822f31c2e3b63819f0834a56d0ecc169
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Öhberg, FredrikSundström, Nina

Søk i DiVA

Av forfatter/redaktør
Öhberg, FredrikSundström, Nina
Av organisasjonen
I samme tidsskrift
Medical Engineering and Physics

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 146 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 189 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf