Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Systematic variability in ICG recordings results in ICG complex subtypes: steps towards the enhancement of ICG characterization
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria; Department of Textile Technology University of Borås, Borås, Sweden.
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria; Department of Textile Technology University of Borås, Borås, Sweden.
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria.
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Journal of Electrical Bioimpedance, E-ISSN 1891-5469, Vol. 9, nr 1, s. 72-82Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The quality of an impedance cardiography (ICG) signal critically impacts the calculation of hemodynamic parameters. These calculations depend solely on the identification of ICG characteristic points on the ABEXYOZ complex. Unfortunately, contrary to the relatively constant morphology of the PQRST complex in electrocardiography, the waveform morphology of ICG data is far from stationary, which causes difficulties in the accuracy of the automated detection of characteristic ICG points. This study evaluated ICG recordings obtained from 10 volunteers. The results indicate that there are several different waveforms for the ABEXYOZ complex; there are up to five clearly distinct waveforms for the ABEXYOZ complex in addition to those that are typically reported. The differences between waveform types increased the difficulty of detecting ICG points. To accurately detect all ICG points, the ABEXYOZ complex should be analyzed according to the corresponding waveform type.

sted, utgiver, år, opplag, sider
Walter de Gruyter, 2018. Vol. 9, nr 1, s. 72-82
Emneord [en]
bioimpedance, impedance cardiography, dZ/dt signal, ABEXYOZ complex, characteristic points, waveform analysis
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-213080DOI: 10.2478/joeb-2018-0012Scopus ID: 2-s2.0-85068998347OAI: oai:DiVA.org:umu-213080DiVA, id: diva2:1789792
Tilgjengelig fra: 2023-08-21 Laget: 2023-08-21 Sist oppdatert: 2023-10-13bibliografisk kontrollert

Open Access i DiVA

fulltext(1568 kB)83 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1568 kBChecksum SHA-512
58b42101a56777ca6ca6b302264df32905a8f7593c86a0d98358032045a2a91d2a90d2da4394834c15cca8a5f266be1fe6e24261b8af38e23484bdfe87dab884
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Benouar, Sara

Søk i DiVA

Av forfatter/redaktør
Benouar, Sara
I samme tidsskrift
Journal of Electrical Bioimpedance

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 90 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 274 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf