Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Assessment of navigated pedicle screws from intraoperative imaging: a prospective study of accuracy and agreement
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap. Spine Unit, Department of Orthopedics, Umeå University Hospital, Umeå, Sweden.ORCID-id: 0000-0002-5920-293X
Epistat AB, Statistical analysis, Uppsala Science Park, Uppsala, Sweden.
Spine Unit, Department of Orthopedics, Umeå University Hospital, Umeå, Sweden.
Section of Neuroradiology, Regional Hospital of Sundsvall, Sundsvall, Sweden.
Vise andre og tillknytning
2023 (engelsk)Inngår i: International Journal of Spine Surgery, E-ISSN 2211-4599, Vol. 17, nr 5, s. 684-689Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Intraoperative (IO) image guidance surgery using 3-dimensional fluoroscopic navigation methods, such as the O-arm system, has improved the accuracy of pedicle screw placement in instrumented spine surgery. IO and postoperative (PO) validation of the implant’s correct position from radiological images is a decisive step to ensure patient safety and avoidance of complications related to implant misplacement. In this prospective single-center study, the authors investigated the accuracy and agreement of assessment of pedicle screws from IO O-arm images in comparison to PO computed tomography images. This study aimed to determine whether a final evaluation of pedicle screws can safely be conducted from IO images that supersede the PO computed tomography control.

Methods: A prospective single-center study was carried out at the Spine Unit in the Department of Orthopedics at Umeå University Hospital between 2019 and 2021. All patients enrolled in the study underwent instrumented thoracolumbar spine surgery using navigation. Imaging data were obtained from IO and PO examinations. Four reviewers—2 attending senior spine surgeons, 1 final year resident in orthopedics, and 1 attending neuroradiologist—classified pedicle screws using the Gertzbein and Robbins classification system. Agreement and accuracy of the reviewers were studied to evaluate the assessment of pedicle screws from IO and PO images.

Results: A total of 70 patients (422 screws) were included in the study. There was high accuracy among surgeons both on IO and PO images (0.96–0.97, 95% CI [0.94–0.99] and 0.97, 95% CI [0.94–0.99], respectively), and the overall agreement between all raters was 92% to 98% (95% CI [0.90, 1.00]). The discrepancy in assessment between optimal (Group 1) and suboptimal (Group 2) screws between IO and PO images was as low as 1% to 1.7%, which indicates that very few suboptimal screws are missed in the assessment of IO images.

Conclusions: The assessment of navigated pedicle screws using IO images is safe and reliable and may replace the need for further assessment using PO imaging.

sted, utgiver, år, opplag, sider
International Society for the Advancement of Spine Surgery (ISASS) , 2023. Vol. 17, nr 5, s. 684-689
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-216249DOI: 10.14444/8550ISI: 001104219800006PubMedID: 37879846Scopus ID: 2-s2.0-85176237434OAI: oai:DiVA.org:umu-216249DiVA, id: diva2:1810075
Tilgjengelig fra: 2023-11-06 Laget: 2023-11-06 Sist oppdatert: 2025-04-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Åkerstedt, JosefinBobinski, Lukas

Søk i DiVA

Av forfatter/redaktør
Åkerstedt, JosefinBobinski, Lukas
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 198 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf