Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
In vitro toxicity evaluation in A549 cells of diesel particulate matter from two different particle sampling systems and several resuspension media
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin.ORCID-id: 0009-0008-1862-8820
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin. CBRN Defence and Security, Swedish Defence Research Agency, Umeå, Sweden.ORCID-id: 0000-0002-8753-830x
CBRN Defence and Security, Swedish Defence Research Agency, Umeå, Sweden.
CBRN Defence and Security, Swedish Defence Research Agency, Umeå, Sweden.
Vise andre og tillknytning
2024 (engelsk)Inngår i: Journal of Applied Toxicology, ISSN 0260-437X, E-ISSN 1099-1263, Vol. 44, nr 8, s. 1269-1278Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In urban areas, inhalation of fine particles from combustion sources such as diesel engines causes adverse health effects. For toxicity testing, a substantial amount of particulate matter (PM) is needed. Conventional sampling involves collection of PM onto substrates by filtration or inertial impaction. A major drawback to those methodologies is that the extraction process can modify the collected particles and alter their chemical composition. Moreover, prior to toxicity testing, PM samples need to be resuspended, which can alter the PM sample even further. Lastly, the choice of the resuspension medium may also impact the detected toxicological responses. In this study, we compared the toxicity profile of PM obtained from two alternative sampling systems, using in vitro toxicity assays. One system makes use of condensational growth before collection in water in an impinger – BioSampler (CG-BioSampler), and the other, a Dekati® Gravimetric Impactor (DGI), is based on inertial impaction. In addition, various methods for resuspension of DGI collected PM were compared. Tested endpoints included cytotoxicity, formation of cellular reactive oxygen species, and genotoxicity. The alternative collection and suspension methods affected different toxicological endpoints. The water/dimethyl sulfoxide mixture and cell culture medium resuspended particles, along with the CG-BioSampler sample, produced the strongest responses. The water resuspended sample from the DGI appeared least toxic. CG-BioSampler collected PM caused a clear increased response in apoptotic cell death. We conclude that the CG-BioSampler PM sampler is a promising alternative to inertial impaction sampling.

sted, utgiver, år, opplag, sider
John Wiley & Sons, 2024. Vol. 44, nr 8, s. 1269-1278
Emneord [en]
apoptosis, diesel exhaust, extraction, impinger, particulate matter, reactive oxygen species, sampling, soot, toxicity
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-224261DOI: 10.1002/jat.4616ISI: 001214370400001PubMedID: 38705171Scopus ID: 2-s2.0-85192155238OAI: oai:DiVA.org:umu-224261DiVA, id: diva2:1857677
Forskningsfinansiär
Swedish Heart Lung FoundationRegion VästerbottenForte, Swedish Research Council for Health, Working Life and WelfareTilgjengelig fra: 2024-05-14 Laget: 2024-05-14 Sist oppdatert: 2024-08-20bibliografisk kontrollert

Open Access i DiVA

fulltext(844 kB)158 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 844 kBChecksum SHA-512
01818e467dcd8e4b982fb8dc45bfc43e0d9aef2fd56c5ca01e0a2b79bab98e6623152cf3c7f7e39b0f14f2b280b332b13faa2c40b14cc923a74f82a1506d5e2d
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Uski, Oskari J.Rankin, Gregory D.Boman, ChristofferMuala, AlaBlomberg, AndersBosson, Jenny A.Sandström, Thomas

Søk i DiVA

Av forfatter/redaktør
Uski, Oskari J.Rankin, Gregory D.Boman, ChristofferMuala, AlaBlomberg, AndersBosson, Jenny A.Sandström, Thomas
Av organisasjonen
I samme tidsskrift
Journal of Applied Toxicology

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 203 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 543 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf