Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Practical issues in assessing nailfold capillaroscopic images: a summary
School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
Medical Image and Signal Processing Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.ORCID-id: 0000-0002-7309-1105
Rheumatology Section, Department of Internal Medicine, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Clinical Rheumatology, ISSN 0770-3198, E-ISSN 1434-9949, Vol. 38, nr 9, s. 2343-2354Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Nailfold capillaroscopy (NC) is a highly sensitive, safe, and non-invasive technique to assess involvement rate of microvascularity in dermatomyositis and systemic sclerosis. A large number of studies have focused on NC pattern description, classification, and scoring system validation, but minimal information has been published on the accuracy and precision of the measurement. The objective of this review article is to identify different factors affecting the reliability and validity of the assessment in NC. Several factors can affect the reliability of the examination, e.g., physiological artifacts, the nailfold imaging instrument, human factors, and the assessment rules and standards. It is impossible to avoid all artifacts, e.g., skin transparency, physically injured fingers, and skin pigmentation. However, minimization of the impact of some of these artifacts by considering some protocols before the examination and by using specialized tools, training, guidelines, and software can help to reduce errors in the measurement and assessment of NC images. Establishing guidelines and instructions for automatic characterization and measurement based on machine learning techniques also may reduce ambiguities and the assessment time.

sted, utgiver, år, opplag, sider
Springer, 2019. Vol. 38, nr 9, s. 2343-2354
Emneord [en]
Assessment, Measurement, Nailfold capillaroscopy
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-229455DOI: 10.1007/s10067-019-04644-9ISI: 000483770400007PubMedID: 31278512Scopus ID: 2-s2.0-85068831307OAI: oai:DiVA.org:umu-229455DiVA, id: diva2:1896330
Tilgjengelig fra: 2024-09-10 Laget: 2024-09-10 Sist oppdatert: 2024-09-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Karbalaie, Abdolamir

Søk i DiVA

Av forfatter/redaktør
Karbalaie, AbdolamirEmrani, Zahra
I samme tidsskrift
Clinical Rheumatology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 60 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf