Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Patient reported fatigue after proton therapy for malignant brain tumours: is there a relation between radiation dose and brain structures?
Radiation Physics, Department of Haematology, Oncology and Radiation Physics, Lund University Hospital, Lund, Sweden; Department of Clinical Sciences, Oncology and Pathology, Lund University, Lund, Sweden.
Institute of Health and Care Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden.
Regional Cancer Centre West, Western Sweden Healthcare Region, Gothenburg, Sweden; Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden.
Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden.
Vise andre og tillknytning
2025 (engelsk)Inngår i: Radiotherapy and Oncology, ISSN 0167-8140, E-ISSN 1879-0887, Vol. 202, artikkel-id 110582Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Fatigue may significantly effect everyday- and working life for radiotherapy patients. Some studies indicate a correlation between radiation dose and irradiated volume of the brain and the presence of fatigue. Our hypothesis was that patient reported outcome measures (PROMs) can improve our understanding of the patients’ symptoms following proton beam therapy (PBT) and optimize PBT for future patients.

Methods: This study included 167 adult patients (>18 years) who received PBT for malignant brain tumours. Data on dose metrics to intra-cranial structures was obtained from PBT treatment plans. To explore fatigue and health related quality of life (HRQoL); Multidimensional Fatigue Inventory (MFI-20) and EORTC QLQ-C30 was used at 6-, 12-, 24- and 36 months post PBT. The correlation between fatigue and dosimetry was explored using Spearman's signed rank test.

Results: No severe fatigue was recorded during the 36 months follow-up. Correlations between higher radiation dose and worsened fatigue scores were generally weak (rho < 0.3). At 12 months post PBT, higher mean dose to the brain, brainstem, hippocampi and pituitary was correlated to worsened MFI Physical Fatigue. Further, Reduced Motivation according to MFI was correlated to higher radiation dose to the brainstem and the pituitary gland. At 36 months follow-up post-PBT, both Reduced Activity and Reduced motivation according to MFI were correlated to higher radiation dose to the brain, brainstem and hippocampi.

Conclusion: Proton beam therapy are well tolerated, with similar degree of fatigue pre- and post PBT. Achieving further reduction in mean brain dose appears beneficial.

sted, utgiver, år, opplag, sider
Elsevier, 2025. Vol. 202, artikkel-id 110582
Emneord [en]
Brain tumour, Fatigue, Proton therapy, Quality of life
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-231324DOI: 10.1016/j.radonc.2024.110582ISI: 001344523900001PubMedID: 39427932Scopus ID: 2-s2.0-85207001817OAI: oai:DiVA.org:umu-231324DiVA, id: diva2:1910076
Forskningsfinansiär
Swedish Cancer Society, CAN2015/428Swedish Cancer Society, CAN2016/809Swedish Foundation for Strategic Research, APR20-0004)Mrs. Berta Kamprad's Cancer Foundation, FBKS-2021Tilgjengelig fra: 2024-11-04 Laget: 2024-11-04 Sist oppdatert: 2025-04-24bibliografisk kontrollert

Open Access i DiVA

fulltext(2873 kB)102 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2873 kBChecksum SHA-512
a09578b730bb525d517c3fdf0a65fe269551c4c46504ab95b5e0bcfcd8a7564e72f3c3056b1ae57d58b9afc28d3b5448bfeae46d60813d0bcdef519a8528929a
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Fransson, Per

Søk i DiVA

Av forfatter/redaktør
Fransson, Per
Av organisasjonen
I samme tidsskrift
Radiotherapy and Oncology

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 102 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 581 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf