Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Energy-efficient control strategy for air conditioning and mechanical ventilation system based on occupant distribution: a case study on stratum ventilation
School of Architecture, Tianjin University, Tianjin, China.
School of Architecture, Tianjin University, Tianjin, China; Tianjin Key Laboratory of Architectural Physical Environment and Ecological Technologies, School of Architecture, Tianjin University, Tianjin, China.
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2025 (engelsk)Inngår i: Journal of Building Engineering, E-ISSN 2352-7102, Vol. 100, artikkel-id 111709Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Existing operation methods of air conditioning and mechanical ventilation system ignore actual occupant distribution, resulting in energy waste due to overcooling and overventilation. To create an acceptable indoor environment while reducing energy consumption of operation, occupant-centric control (OCC) strategy has been proposed and developed. In this study, the proposed OCC strategy adjusts on/off of air supply vents and sub-zone air supply parameters according to sub-zone occupancy, involving two sub-zone air supply volume allocation methods, so as to prioritize thermal comfort and air quality in local occupied zone. Computational fluid dynamics was employed to evaluate the OCC strategy's performance in the case of applying stratum ventilation. The results show that the predicted mean vote at 0.6 m height is kept at 0.29–0.53, and the CO2 concentration at 1.1 m is controlled below 1100 ppm, which can achieve energy savings of 18–51 % (compared to Baseline 1) and 4–16 % (compared to Baseline 2). Moreover, the larger the difference in the number of occupants between sub-zones, the more energy savings the OCC strategy can achieve. It is suggested that sub-zone air supply volume should be allocated according to sub-zone cooling load and the outdoor air ratio in critical sub-zone should be employed to compensate for total outdoor air volume. This study provides an approach to combine the OCC strategy with non-uniform air distribution, offering insights into the balance of energy efficiency and occupied environmental comfort in system operation.

sted, utgiver, år, opplag, sider
Elsevier, 2025. Vol. 100, artikkel-id 111709
Emneord [en]
Air quality, Energy savings, Occupant distribution, Occupant-centric control, Stratum ventilation, Thermal comfort
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-233994DOI: 10.1016/j.jobe.2024.111709ISI: 001407731200001Scopus ID: 2-s2.0-85214122233OAI: oai:DiVA.org:umu-233994DiVA, id: diva2:1927471
Tilgjengelig fra: 2025-01-15 Laget: 2025-01-15 Sist oppdatert: 2025-04-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Liu, Pengju

Søk i DiVA

Av forfatter/redaktør
Liu, Pengju
Av organisasjonen
I samme tidsskrift
Journal of Building Engineering

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 27 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf