Potentials and effects of electricity cogeneration via ORC integration in small-scale biomass district heating system
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.ORCID-id: 0000-0002-0588-9510
Department of Built Environment and Energy Technology, Linnaeus University, Växjö, Sweden.
2025 (engelsk)Inngår i: Green Energy and Resources, E-ISSN 2949-7205, Vol. 3, nr 1, artikkel-id 100113Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This study explores the potential and impact of electricity cogeneration using Organic Rankine Cycle (ORC) integrated with small-scale biomass boilers within district heating systems. An analysis is conducted on a 3 MWth biomass-fired district heating plant in southern Sweden. Process monitoring data, collected over a one-year period from the plant, serves as the basis for simulation and analysis. The study examines operational changes and fuel usage at a local level, together with an extension to a regional scale considering both short-term and long-term energy system implications. The results show that integrating a 200 kWe ORC unit with the existing boiler having a flue gas condenser is cost-optimal and could cogenerate approximately 1.1 GWh electricity annually, with a levelized electricity cost of €64.4 per MWh. This is equivalent to a system power-to-heat ratio of 7.5%. From a broader energy system perspective, this efficient integration could potentially reduce CO2 emissions by 234∼454 tons per year when the saved energy locally is used to replace fossil fuels in the energy system, depending on how biomass is utilized and what type of fossil fuels are replaced. Increasing installed capacity of ORC unit to maximize electricity co-generation could result in a carbon abatement cost ranging from €204 to €79 per ton CO2. This cost fluctuates depending on the installed capacity, operation of the ORC units, and prevailing electricity prices. The study highlights the trade-off between financial gains and CO2 emission reductions, underscoring the complex decision-making involved in energy system optimization.

sted, utgiver, år, opplag, sider
Elsevier, 2025. Vol. 3, nr 1, artikkel-id 100113
Emneord [en]
Biomass conversion, District heating system, Electricity cogeneration, GHG emissions, Organic rankine cycle, Primary energy use, Small-scale boiler
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-234666DOI: 10.1016/j.gerr.2024.100113Scopus ID: 2-s2.0-85215389665OAI: oai:DiVA.org:umu-234666DiVA, id: diva2:1936165
Forskningsfinansiär
European Regional Development Fund (ERDF)Tilgjengelig fra: 2025-02-10 Laget: 2025-02-10 Sist oppdatert: 2025-02-10bibliografisk kontrollert

Open Access i DiVA

fulltext(4451 kB)302 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4451 kBChecksum SHA-512
e85572dade71ebf713c89d73d0e8f858a7522c705b8c4a89990244cd396c469acd2920d3a69ad34f0f4026f1a6e18c2cbc90d3cc369d75b4326f5319dc3c57ec
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Truong, Nguyen Le

Søk i DiVA

Av forfatter/redaktør
Truong, Nguyen Le
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 302 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 441 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf