Ultra-fast, one-click radiotherapy treatment planning outside a treatment planning systemVise andre og tillknytning
2025 (engelsk)Inngår i: Physics and Imaging in Radiation Oncology, E-ISSN 2405-6316, Vol. 33, artikkel-id 100724Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]
We present an automated radiation oncology treatment planning pipeline that operates between segmentation and plan review, minimizing manual interaction and reliance on traditional planning systems. Two AI models work in sequence: the first generates a dose distribution, and the second creates a deliverable DICOM-RT plan. Trained and validated on 276 plans, and tested on 151 datasets, the system produced clinically deliverable plans—complete with all VMAT parameters—in about 38 s. These plans met target coverage and most organ-at-risk constraints. This proof-of-concept demonstrates the feasibility of generating high-quality, deliverable DICOM plans within seconds.
sted, utgiver, år, opplag, sider
Elsevier, 2025. Vol. 33, artikkel-id 100724
Emneord [en]
Artificial intelligence, Auto-planning, Automation, Deep learning, Prostate, Treatment planning, VMAT
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-235676DOI: 10.1016/j.phro.2025.100724ISI: 001426515800001Scopus ID: 2-s2.0-85217390700OAI: oai:DiVA.org:umu-235676DiVA, id: diva2:1939278
2025-02-212025-02-212025-04-24bibliografisk kontrollert