Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Field validation of the Ogawa diffusive sampler for NO(2) and NO(x) in a cold climate
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin. (Arcum)
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.ORCID-id: 0000-0001-8608-0168
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin. (Arcum)
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin. (Arcum)
2010 (engelsk)Inngår i: Journal of Environmental Monitoring, ISSN 1464-0325, E-ISSN 1464-0333, Vol. 12, nr 6, s. 1315-24Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A small-scale field trial in Umeå, Sweden with Ogawa samplers and a chemiluminescence instrument indicated that the NO(2) concentration was underestimated with respect to the reference monitor, if calculated according to the manufacturer's Ogawa sampling protocol. By co-locating Ogawa samplers and reference monitors at six sites in two Swedish cities, uptake rates were determined for NO(2) and NO(x) better applicable to the Swedish conditions and climate. The concentrations of NO(2) and NO(x) calculated according to the instruction manual of the sampler and using the field-determined uptake rates were compared with values derived from chemiluminescence monitors for each week over which samples were taken. When calculated according to the manufacturer's suggested protocol, the Ogawa sampler underestimated the NO(2) concentrations by 9.1% on average for all samples (N = 53), with respect to the reference monitor. In contrast, NO(x) concentrations were overestimated by a mean value of 15% for all samples (N = 45). By using the field determined uptake rates for the calculation of NO(2) and NO(x) a better estimation of the concentrations was obtained. The ratio between concentrations determined with the Ogawa samplers and chemiluminescence monitors was then 1.02 for all measurements of NO(2) and 1.00 for NO(x). Precision, expressed as the mean coefficient of variation, was 6.4% for six, 6-replicate measurements of NO(2) and 3.7% for five, 6-replicate measurements of NO(x).

sted, utgiver, år, opplag, sider
Royal Society of Chemistry, 2010. Vol. 12, nr 6, s. 1315-24
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-34783DOI: 10.1039/b924615kISI: 000278588400012PubMedID: 20532384Scopus ID: 2-s2.0-77953449315OAI: oai:DiVA.org:umu-34783DiVA, id: diva2:325308
Tilgjengelig fra: 2010-06-18 Laget: 2010-06-18 Sist oppdatert: 2024-03-25bibliografisk kontrollert
Inngår i avhandling
1. Validation of diffusive samplers for nitrogen oxides and applications in various environments
Åpne denne publikasjonen i ny fane eller vindu >>Validation of diffusive samplers for nitrogen oxides and applications in various environments
2014 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The overall aim of this thesis was to validate diffusive samplers for measurements of nitrogen dioxide (NO2) and nitrogen oxides (NOx). The Willems badge was validated for NO2 measurements both in laboratory tests and in field tests (Paper I-II). The sampling rate was 40.0 mL/min for ambient air concentrations and 46.0 mL/min for higher concentrations. No effects of different factors on sampling rate were found except for a reduced sampling rate at low wind velocity. The results of the laboratory validation were confirmed in field tests in ambient air and with personal sampling. The correlation between diffusive samplers and the reference monitor was good for ambient measurements. In conclusion, the Willems badge performs well at wind velocities down to 0.3 m/s, and this makes it suitable for personal sampling but less suitable for measurements in indoor air where the wind velocity is lower. Paper III reports about the field validation of the Ogawa diffusive samplers. Absolute humidity and temperature were found to have the strongest effect on sampling rate with lower uptake rates at low absolute humidity or temperature. The sampling rates above 0 °C were 8.6 mL/min for NO2 and 9.9 mL/min for NOx. NO2 and NOx concentrations that were determined using the manufacturer’s protocol were either underestimated or overestimated. The agreement between concentrations measured by the Ogawa sampler and the reference monitor was improved when field-determined sampling rates were used to calculate concentrations. Paper IV is based on a study with the aim of assessing the exposure of the Swedish general population to NO2 and some carcinogenic substances. The surveys were performed in one of five Swedish cities every year. In each survey, personal measurements of NO2 and some carcinogenic substances were conducted on 40 randomly selected individuals. In the study presented in this thesis, the NO2 part of the study is in focus and results were available for eight surveys conducted across the five cities. The estimated arithmetic mean concentration for the general Swedish population was 14.1 μg/m3. The exposure level for NO2 was higher for smokers compared with non-smokers, and the NO2 exposure levels were higher for people who had gas stoves at home or who were exposed at their workplace. The exposure was lower for those who had oil heating in their houses.

sted, utgiver, år, opplag, sider
Umeå: Umeå universitet, 2014. s. 67
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1685
Emneord
Nitrogen dioxide, NOx, diffusive sampling, validation, vehicle exhaust, exposure measurement
HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-95757 (URN)978-91-7601-144-7 (ISBN)
Disputas
2014-11-28, Hörsal B Unod T 9, Norrlands universitetssjukhus, Umeå, 09:00 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2014-11-07 Laget: 2014-11-05 Sist oppdatert: 2018-06-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Hagenbjörk-Gustafsson, AnnikaTornevi, AndreasForsberg, BertilEriksson, Kåre

Søk i DiVA

Av forfatter/redaktør
Hagenbjörk-Gustafsson, AnnikaTornevi, AndreasForsberg, BertilEriksson, Kåre
Av organisasjonen
I samme tidsskrift
Journal of Environmental Monitoring

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 919 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf