Initial recombination in the track of heavy charged particles: numerical solution for air filled ionization chambers
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
2012 (engelsk)Inngår i: Acta Oncologica, ISSN 0284-186X, E-ISSN 1651-226X, Vol. 51, nr 3, s. 368-375Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Introduction. Modern particle therapy facilities enable sub-millimeter precision in dose deposition. Here, also ionization chambers (ICs) are used, which requires knowledge of the recombination effects. Up to now, recombination is corrected using phenomenological approaches for practical reasons. In this study the effect of the underlying dose distribution on columnar recombination, a quantitative model for initial recombination, is investigated.

Material and methods. Jaffé's theory, formulated in 1913 quantifies initial recombination by elemental processes, providing an analytical (closed) solution. Here, we investigate the effect of the underlying charged carrier distribution around a carbon ion track. The fundamental partial differential equation, formulated by Jaffé, is solved numerically taking into account more realistic charge carrier distributions by the use of a computer program (Gascoigne 3D). The investigated charge carrier distributions are based on track structure models, which follow a 1∕r(2) behavior at larger radii and show a constant value at small radii. The results of the calculations are compared to the initial formulation and to data obtained in experiments using carbon ion beams.

Results. The comparison between the experimental data and the calculations shows that the initial approach made by Jaffé is able to reproduce the effects of initial recombination. The amorphous track structure based charge carrier distribution does not reproduce the experimental data well. A small additional correction in the assessment of the saturation current or charge is suggested by the data.

Conclusion. The established model of columnar recombination reproduces the experimental data well, whereas the extensions using track structure models do not show such an agreement. Additionally, the effect of initial recombination on the saturation curve (i.e. Jaffé plot) does not follow a linear behavior as suggested by current dosimetry protocols, therefore higher order corrections (such as the investigated ones) might be necessary.

sted, utgiver, år, opplag, sider
Informa Healthcare, 2012. Vol. 51, nr 3, s. 368-375
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-49401DOI: 10.3109/0284186X.2011.626452ISI: 000302731800012PubMedID: 22047061Scopus ID: 2-s2.0-84859761842OAI: oai:DiVA.org:umu-49401DiVA, id: diva2:455606
Tilgjengelig fra: 2011-11-10 Laget: 2011-11-10 Sist oppdatert: 2025-02-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Tölli, Heikki

Søk i DiVA

Av forfatter/redaktør
Tölli, Heikki
Av organisasjonen
I samme tidsskrift
Acta Oncologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 286 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf