Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Detecting small liver tumors with In-111-Pentetreotide SPECT-A Collimator study based on Monte Carlo simulations
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
2012 (engelsk)Inngår i: IEEE Transactions on Nuclear Science, ISSN 0018-9499, E-ISSN 1558-1578, Vol. 59, nr 1, s. 47-53Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In In-111- pentetreotide single-photon emission computed tomography (SPECT), the tumor-to-background-uptake ratio is generally high. The noise is, however, also usually on a high level, and in combination with the low spatial resolution of SPECT, this may lead to difficulties in the detection of small tumors. This is especially the case in regions with a relatively high background activity, such as in the liver, which is a common region for somatostatin-positive metastases. Visually detecting the small tumors is important for a successful treatment of the cancer disease. In this paper, we compare three different parallel-hole collimators for In-111-pentetreotide SPECT regarding contrast as a function of image noise for a phantom simulating small tumors in liver background. The corresponding contrast-to-noise ratios are also presented. All raw-data projections are produced using Monte Carlo simulations. The collimators are of type low-energy general-purpose (LEGP), extended LEGP (ELEGP), and medium-energy general-purpose (MEGP). Reconstructions were performed with OSEM both with and without model-based compensation. Of the investigated collimators, the ELEGP collimator proved to be the most optimal for the smallest tumors, both with and without model-based compensation included in the reconstruction. It is also shown that model-based compensation outperforms the conventional reconstruction technique.

sted, utgiver, år, opplag, sider
IEEE , 2012. Vol. 59, nr 1, s. 47-53
Emneord [en]
In-111-pentetreotide, liver tumor, model-based compensation, single-photon emission computed tomography (SPECT)
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-53115DOI: 10.1109/TNS.2011.2172815ISI: 000300422500007Scopus ID: 2-s2.0-84857363089OAI: oai:DiVA.org:umu-53115DiVA, id: diva2:510030
Tilgjengelig fra: 2012-03-14 Laget: 2012-03-13 Sist oppdatert: 2023-03-23bibliografisk kontrollert

Open Access i DiVA

fulltext(997 kB)1278 nedlastinger
Filinformasjon
Fil FULLTEXT03.pdfFilstørrelse 997 kBChecksum SHA-512
0b2731a4271e362f9690c928fca1b93e565cf5a9b89183ee629dbc1f3832a25b4f48c14c9f24b8673c32b87e24b79913b1038fce8c0ca487f89de226b84bb964
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Mähler, EmmaSundström, TorbjörnAxelsson, JanLarsson, Anne

Søk i DiVA

Av forfatter/redaktør
Mähler, EmmaSundström, TorbjörnAxelsson, JanLarsson, Anne
Av organisasjonen
I samme tidsskrift
IEEE Transactions on Nuclear Science

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1278 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 625 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf