Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Laboratory or field tests for evaluating firefighters' work capacity
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Idrottsmedicin. Winternet, Boden.ORCID-id: 0000-0002-2339-6381
Physical Work Capacity Team, Finnish Institute of Occupational Health, Oulu, Finland.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Idrottsmedicin.ORCID-id: 0000-0002-8436-2476
2014 (engelsk)Inngår i: PLOS ONE, E-ISSN 1932-6203, Vol. 9, nr 3, s. e91215-Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs= −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

sted, utgiver, år, opplag, sider
Public Library of Science , 2014. Vol. 9, nr 3, s. e91215-
Emneord [en]
contained breathing apparatus; physically demanding tasks; physiological demands; muscle strength; ability test; performance; fitness; fire; responses; gender
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-86901DOI: 10.1371/journal.pone.0091215ISI: 000332839300097PubMedID: 24614596Scopus ID: 2-s2.0-84897516295OAI: oai:DiVA.org:umu-86901DiVA, id: diva2:704662
Tilgjengelig fra: 2014-03-13 Laget: 2014-03-13 Sist oppdatert: 2025-02-11bibliografisk kontrollert
Inngår i avhandling
1. Firefighters' physical work capacity
Åpne denne publikasjonen i ny fane eller vindu >>Firefighters' physical work capacity
2014 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Alternativ tittel[sv]
Brandmäns fysiska arbetskapacitet
Abstract [en]

The overall aim of this thesis was to identify valid, simple, and inexpensive physical tests that can be used for evaluation of firefighters’ physical work capacity. Paper I included fulltime- and part-time firefighters (n = 193), aged 20-60 years. Perceived physical demands of firefighting work tasks were ranked, and comparisons between subject groups rating were done with the Mann Whitney U-test and Binominal test. Papers II and III included male firefighters and civilian men and women (n = 38), aged 24-57 years. Laboratory and field tests of aerobic fitness, muscle strength and endurance, balance, and simulated firefighting work tasks were performed. Physical capacity comparisons between subject groups were done and bivariate correlations between physical tests and work capacity in the simulated firefighting work tasks analyzed. Paper IV included the same subjects as in Paper II-III (training-set), and additional 90 subjects (prediction-set), aged 20-50 years. Laboratory and field tests of aerobic fitness, muscle strength and endurance and balance, and simulated firefighting work tasks were included. Data from the training-set was used to build models for prediction of firefighters’ physical work capacity, using multivariate statistic. The prediction-set was used to externally validate the selected models. Several work tasks were rated as physically demanding and significant differences (p < 0.05) in ratings were found between full-time and part-time firefighters (Paper I). Significant differences were found between subject groups in physical capacity, and work capacity (p < 0.01) (Paper II-IV). Both laboratory and field tests were significantly (p < 0.01) correlated with work capacity time (Paper II-III). The prediction (R2) and predictive power (Q2) of firefighters’ work capacity (Carrying hose baskets upstairs, Hose pulling, Demolition at or after a fire, Victim rescue, and Carrying hose baskets over terrain) was R2 = 0.74 to 0.91, and Q2 = 0.65 to 0.85, and the external validation ranged between R2: 0.38 to 0.80 (Paper IV).

In conclusion, rowing 500 m (s), maximal handgrip strength (kg), endurance bench press (n), running 3000 m (s and s scaled to body weight) upright barbell row (n) and standing broad jump (m) together provides valid information about firefighters’ physical work capacity. 

sted, utgiver, år, opplag, sider
Umeå: Umeå Universitet, 2014. s. 67
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1652
Emneord
Physical demands, performance, work capacity, aerobic fitness, anaerobic fitness, muscle strength, muscle endurance, balance, ergonomics, physical testing, SIMCA
HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-88729 (URN)978-91-7601-054-9 (ISBN)
Disputas
2014-06-13, Biologihuset, Rum A 201, Umeå Universitet, Umeå, 13:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2014-05-23 Laget: 2014-05-13 Sist oppdatert: 2025-02-11bibliografisk kontrollert

Open Access i DiVA

fulltext(261 kB)558 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 261 kBChecksum SHA-512
4e0fc7cf664a5a99dc00661d6753524571bd55ae18a450dcc96a0d73b85a9d2bea7d717953536f45dd85796d2b94c9dc6b6c9865de895c828ca65bdf1bcc4de9
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Lindberg, Ann-SofieMalm, Christer

Søk i DiVA

Av forfatter/redaktør
Lindberg, Ann-SofieMalm, Christer
Av organisasjonen
I samme tidsskrift
PLOS ONE

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 564 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 727 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf