Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Can we trust intraocular pressure measurements in eyes with intracameral air?
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.ORCID-id: 0000-0003-0218-4563
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0002-2031-722X
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Vise andre og tillknytning
2014 (engelsk)Inngår i: Graefe's Archives for Clinical and Experimental Ophthalmology, ISSN 0721-832X, E-ISSN 1435-702X, Vol. 252, nr 10, s. 1607-1610Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

PURPOSE: To evaluate the effect of intracameral air on intraocular pressure (IOP) measurements using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) in an in-vitro porcine eye model.

METHODS: IOP was measured on thirteen freshly enucleated eyes at three reference pressures: 20, 30, and 40 mmHg. Six measurements/method were performed in a standardized order with GAT and ART respectively. Air was injected intracamerally in the same manner as during Descemet's stripping endothelial keratoplasty (DSEK) and Descemet's membrane endothelial keratoplasty (DMEK), and the measurements were repeated.

RESULTS: Measured IOP increased significantly for both tonometry methods after air injection: 0.7 ± 2.1 mmHg for GAT and 10.6 ± 4.9 mmHg for ART. This difference was significant at each reference pressure for ART but not for GAT.

CONCLUSIONS: Although slightly affected, this study suggests that we can trust GAT IOP-measurements in eyes with intracameral air, such as after DSEK/DMEK operations. Ultrasound-based methods such as ART should not be used.

sted, utgiver, år, opplag, sider
Springer, 2014. Vol. 252, nr 10, s. 1607-1610
Emneord [en]
intraocular pressure; intracameral air; Goldmann applanation tonometry; applanation resonance tonometry; DSEK; DMEK
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-96875DOI: 10.1007/s00417-014-2720-5ISI: 000344631600012PubMedID: 25030238Scopus ID: 2-s2.0-84925884284OAI: oai:DiVA.org:umu-96875DiVA, id: diva2:769003
Tilgjengelig fra: 2014-12-05 Laget: 2014-12-05 Sist oppdatert: 2024-01-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Jóhannesson, GautiLindén, ChristinaEklund, AndersBehndig, AndersHallberg, Per

Søk i DiVA

Av forfatter/redaktør
Jóhannesson, GautiLindén, ChristinaEklund, AndersBehndig, AndersHallberg, Per
Av organisasjonen
I samme tidsskrift
Graefe's Archives for Clinical and Experimental Ophthalmology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 615 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf