Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Numerical simulation of the fracture process in ceramic FPD frameworks caused by oblique loading
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
Institute of Mechanics, Chinese Academy of Sciences, Beijing, China.
Institute of Mechanics, Chinese Academy of Sciences, Beijing, China.
Institute of Mechanics, Chinese Academy of Sciences, Beijing, China.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Journal of The Mechanical Behavior of Biomedical Materials, ISSN 1751-6161, E-ISSN 1878-0180, Vol. 50, s. 206-214Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Using a newly developed three-dimensional (3D) numerical modeling code, an analysis was performed of the fracture behavior in a three-unit ceramic-based fixed partial denture (FPD) framework subjected to oblique loading. All the materials in the study were treated heterogeneously; Weibull׳s distribution law was applied to the description of the heterogeneity. The Mohr-Coulomb failure criterion with tensile strength cut-off was utilized in judging whether the material was in an elastic or failed state. The simulated loading area was placed either on the buccal or the lingual cusp of a premolar-shaped pontic with the loading direction at 30°, 45°, 60°, 75° or 90° angles to the occlusal surface. The stress distribution, fracture initiation and propagation in the framework during the loading and fracture process were analyzed. This numerical simulation allowed the cause of the framework fracture to be identified as tensile stress failure. The decisive fracture was initiated in the gingival embrasure of the pontic, regardless of whether the buccal or lingual cusp of the pontic was loaded. The stress distribution and fracture propagation process of the framework could be followed step by step from beginning to end. The bearing capacity and the rigidity of the framework vary with the loading position and direction. The framework loaded with 90° towards the occlusal surface has the highest bearing capacity and the greatest rigidity. The framework loaded with 30° towards the occlusal surface has the least rigidity indicating that oblique loading has a major impact on the fracture of ceramic frameworks.

sted, utgiver, år, opplag, sider
2015. Vol. 50, s. 206-214
Emneord [en]
Finite element analysis, Fixed partial denture, Fracture process, Numerical simulation, Oblique loading
HSV kategori
Forskningsprogram
numerisk analys
Identifikatorer
URN: urn:nbn:se:umu:diva-105213DOI: 10.1016/j.jmbbm.2015.06.017ISI: 000361775000019PubMedID: 26143353Scopus ID: 2-s2.0-84969718668OAI: oai:DiVA.org:umu-105213DiVA, id: diva2:824061
Tilgjengelig fra: 2015-06-19 Laget: 2015-06-19 Sist oppdatert: 2023-03-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Kou, WenSjögren, Göran

Søk i DiVA

Av forfatter/redaktør
Kou, WenSjögren, Göran
Av organisasjonen
I samme tidsskrift
Journal of The Mechanical Behavior of Biomedical Materials

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 546 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf