Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A resonator sensor for measurement of intraocular pressure--evaluation in an in vitro pig-eye model.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.ORCID-id: 0000-0002-2031-722X
2000 (Engelska)Ingår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 21, nr 3, s. 355-67Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Intraocular pressure (IOP) measurement is performed routinely at every eye clinic. High IOP, which can be a sign of glaucoma, can lead to degeneration of the retina and can cause blindness. In this study we developed a resonator sensor for IOP measurement based on an oscillator consisting of a piezoelectric element made of lead zirconate titanate, a flat contact piece of nylon and a feedback circuit. The aim of this study was to evaluate the new sensor's ability to determine lOP in an in vitro pig-eye model. Six eyes from four pigs were removed and fixed in agar. They were then pressurized by a saline column (10-35 cm H2O) through a cannula inserted into the vitreous chamber. The IOP was measured with the resonator sensor applied to cornea. An Alcon applanation pneumatonometer and a standard Viggo-Spectramed pressure sensor connected to the saline column were used as references. The IOP as measured with the resonator sensor correlated well with the pressure elicited by the saline column for individual eyes (r = 0.96-0.99, n = 60) and for all eyes (r = 0.92, n = 360). The correlation between the resonance sensor and the pneumatonometer was r = 0.92 (n = 360). The pneumatonometer also showed a good correlation with the saline column (r = 0.98, n = 360). We conclude that our in vitro pig-eye model made it possible to induce reproducible variation in IOP, and measurement of that pressure with the newly developed resonator sensor gave very promising results for development of a clinically applicable IOP tonometer with unique properties.

Ort, förlag, år, upplaga, sidor
2000. Vol. 21, nr 3, s. 355-67
Nationell ämneskategori
Medicinteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-135120PubMedID: 10984204Scopus ID: 2-s2.0-0033863370OAI: oai:DiVA.org:umu-135120DiVA, id: diva2:1096759
Tillgänglig från: 2017-05-19 Skapad: 2017-05-19 Senast uppdaterad: 2023-03-23

Open Access i DiVA

Fulltext saknas i DiVA

PubMedScopus

Person

Eklund, Anders

Sök vidare i DiVA

Av författaren/redaktören
Eklund, Anders
Av organisationen
Institutionen för strålningsvetenskaper
I samma tidskrift
Physiological Measurement
Medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetricpoäng

pubmed
urn-nbn
Totalt: 87 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf