Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Successful Treatment of Femoral Chondral Lesions with a Novel Customized Metal Implant at Midterm Follow-Up
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Ortopedi.ORCID-id: 0000-0002-8562-0713
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Cartilage, ISSN 1947-6035, E-ISSN 1947-6043, Vol. 13, nr Suppl 1, s. 1726S-1733SArtikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background Full-depth cartilage lesions do not heal spontaneously and may progress to osteoarthritis (OA). Treatment for these lesions is warranted when symptomatic. At younger age, biological treatment remains the gold standard, but treatment in the middle-aged patient remains a clinical challenge and focal metal implants have been proposed. We aim to present the subjective outcome at 2 years and the risk of reoperation for any reason at midterm after surgery with a novel customized implant for focal femoral chondral lesions in the knee.

Methods In a prospective cohort study, 30 patients were included between January 2013 and December 2017 at 9 different clinics in Sweden. The primary outcome was subjective outcome measurements (Visual Analogue Scale [VAS], EuroQoL [EQ5D], Knee injury and Osteoarthritis Outcome Score [KOOS]) at a minimum of 2 years. The secondary outcome was reoperations for any reason during the follow-up period until December 2019 (mean of 55 months) studied retrospectively by analyzing medical records.

Results The VAS, EQ5D, and all the KOOS subscales showed significant improvements from preoperatively to the 2-year follow-up. The VAS showed the greatest improvement at the early (3 months) postoperative stage (P < 0.001). Five (7%) patients underwent reoperations and one of these was revised to hemiarthroplasty due to OA progression. No implant loosening was detected in any of the cases.

ConclusionsThis customized resurfacing metal implant showed good safety and patient satisfaction. The risk of OA progression and implant loosening is low. Subjective function and pain improved significantly.

Ort, förlag, år, upplaga, sidor
Sage Publications, 2021. Vol. 13, nr Suppl 1, s. 1726S-1733S
Nyckelord [en]
clinical trial, general, outcome measures, articular cartilage, tissue, knee, joint involved, resurfacing, procedures
Nationell ämneskategori
Ortopedi
Identifikatorer
URN: urn:nbn:se:umu:diva-178698DOI: 10.1177/1947603520967064ISI: 000598434200001PubMedID: 33106003Scopus ID: 2-s2.0-85094601732OAI: oai:DiVA.org:umu-178698DiVA, id: diva2:1517548
Tillgänglig från: 2021-01-14 Skapad: 2021-01-14 Senast uppdaterad: 2022-04-19Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Högström, Magnus

Sök vidare i DiVA

Av författaren/redaktören
Högström, Magnus
Av organisationen
Ortopedi
I samma tidskrift
Cartilage
Ortopedi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 63 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf