Measuring Athletic Performance UsingAccelerometers
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik.
2023 (Engelska)Självständigt arbete på avancerad nivå (yrkesexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

With help from a 3D-camera Photon Sports has developed reliable and easy-to-use technology tomeasure and give feedback to athletes during performance tests. This technology makes it possibleto directly extract a number of parameters Key Performance Indicators (KPIs).In most field sports, multidirectional acceleration and deceleration are key areas to improveto become quicker as an athlete. However, it has become clear that only using the 3D-camera hassome limitations. This project aims to investigate if accelerometers can provide us with this extrainformation and thereby complement measurement technology to the measurements PhotonSports are doing today.We have done a three-part project where we first focused on time synchronization betweenclocks from the 3D-camera and the accelerometers. In the second part, we investigated how wellwe can extract the ground contact time (gct) during sprint using accelerometers attached to thefeet of the athlete. In the third and last part, we studied how we can combine both the 3D-cameraand the accelerometers to extract new KPIs that we were unable to extract before.From our developed time-synchronization algorithm, we found that the result is promisingif one looks at how the measured acceleration data from both devices are matching each othervisualy, however, it does not agree with the reference data we have extracted using a Software-Development-Kit (SDK) and Photon Sports already developed application. The gct was evaluatedto values in most cases either ranging between 100 ms and 200 ms or 300 ms and 400 ms. Whencomparing to earlier studies it seems like gct in the 100−200 ms interval are closer to the correctvalue whilst there has been some error in the calculations in the later interval. By combiningthe camera and the accelerometers we were able to extract leg stiffness and reactivity index as newKPIs. The KPIswere evaluated to a reasonable value, however, it became apparent both fromcalculationsof the newKPIs and the gct that the lowsampling rate of the camera and the accelerometersare an obstacle to reliably compute these parameters. We could therefor conclude that if PhotonSports want to introduce new tests where accelerometers are used they should be aware of the limitationsthat comes with i low sampling rate and be sure they try to compute KPIs that are possibleto evaluate with the sampling rate they have.

Ort, förlag, år, upplaga, sidor
2023. , s. 28
Nationell ämneskategori
Subatomär fysik
Identifikatorer
URN: urn:nbn:se:umu:diva-209827OAI: oai:DiVA.org:umu-209827DiVA, id: diva2:1767754
Externt samarbete
Photon Sports
Ämne / kurs
Examensarbete i teknisk fysik
Utbildningsprogram
Civilingenjörsprogrammet i Teknisk fysik
Presentation
2023-06-08, Hörsal NAT.D.410 Umeå Universitet, Universitetsvägen, 901 87 Umeå, Umeå, 16:00 (Svenska)
Handledare
Examinatorer
Tillgänglig från: 2023-06-21 Skapad: 2023-06-14 Senast uppdaterad: 2025-02-14Bibliografiskt granskad

Open Access i DiVA

fulltext(6400 kB)907 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 6400 kBChecksumma SHA-512
8fc864337bb013878c64912819ccc9b83cfc100a079e92b1ee503cf93a9e846cd16d64bb97d840077949494bde7b3e8ebafbce4216794fc1acc8c9b963d7d532
Typ fulltextMimetyp application/pdf

Av organisationen
Institutionen för fysik
Subatomär fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 911 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 509 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf