Energy-efficient control strategy for air conditioning and mechanical ventilation system based on occupant distribution: a case study on stratum ventilation
School of Architecture, Tianjin University, Tianjin, China.
School of Architecture, Tianjin University, Tianjin, China; Tianjin Key Laboratory of Architectural Physical Environment and Ecological Technologies, School of Architecture, Tianjin University, Tianjin, China.
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2025 (Engelska)Ingår i: Journal of Building Engineering, E-ISSN 2352-7102, Vol. 100, artikel-id 111709Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Existing operation methods of air conditioning and mechanical ventilation system ignore actual occupant distribution, resulting in energy waste due to overcooling and overventilation. To create an acceptable indoor environment while reducing energy consumption of operation, occupant-centric control (OCC) strategy has been proposed and developed. In this study, the proposed OCC strategy adjusts on/off of air supply vents and sub-zone air supply parameters according to sub-zone occupancy, involving two sub-zone air supply volume allocation methods, so as to prioritize thermal comfort and air quality in local occupied zone. Computational fluid dynamics was employed to evaluate the OCC strategy's performance in the case of applying stratum ventilation. The results show that the predicted mean vote at 0.6 m height is kept at 0.29–0.53, and the CO2 concentration at 1.1 m is controlled below 1100 ppm, which can achieve energy savings of 18–51 % (compared to Baseline 1) and 4–16 % (compared to Baseline 2). Moreover, the larger the difference in the number of occupants between sub-zones, the more energy savings the OCC strategy can achieve. It is suggested that sub-zone air supply volume should be allocated according to sub-zone cooling load and the outdoor air ratio in critical sub-zone should be employed to compensate for total outdoor air volume. This study provides an approach to combine the OCC strategy with non-uniform air distribution, offering insights into the balance of energy efficiency and occupied environmental comfort in system operation.

Ort, förlag, år, upplaga, sidor
Elsevier, 2025. Vol. 100, artikel-id 111709
Nyckelord [en]
Air quality, Energy savings, Occupant distribution, Occupant-centric control, Stratum ventilation, Thermal comfort
Nationell ämneskategori
Husbyggnad Energiteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-233994DOI: 10.1016/j.jobe.2024.111709ISI: 001407731200001Scopus ID: 2-s2.0-85214122233OAI: oai:DiVA.org:umu-233994DiVA, id: diva2:1927471
Tillgänglig från: 2025-01-15 Skapad: 2025-01-15 Senast uppdaterad: 2025-04-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Liu, Pengju

Sök vidare i DiVA

Av författaren/redaktören
Liu, Pengju
Av organisationen
Institutionen för tillämpad fysik och elektronik
I samma tidskrift
Journal of Building Engineering
HusbyggnadEnergiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 132 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf