Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Real-time digital twin-driven 3D near-miss detection system at construction sites
Dept. of Civil Engineering, Harbin Institute of Technology, Harbin, China.
Key Lab of Structures Dynamic Behavior and Control, Dept. of Civil Engineering, Harbin Institute of Technology, Harbin, China.
Guangdong Provincial Key Laboratory of Intelligent and Resilient Structures for Civil Engineering, Dept. of Civil and Environmental Engineering, Harbin Institute of Technology, Shenzhen, China.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.ORCID-id: 0000-0002-9310-9093
2025 (Engelska)Ingår i: Journal of construction engineering and management, ISSN 0733-9364, E-ISSN 1943-7862, Vol. 151, nr 4, artikel-id 04025021Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

To enhance on-site safety management, detecting near-misses in a timely and accurate manner is crucial. However, traditional monitoring methods that rely on inspectors are time-consuming, labor-intensive, and limited in their ability to detect three-dimensional (3D) incidents. Digital twin technology presents a promising solution by integrating real-time monitoring, simulation and interactivity capabilities in three dimensional virtual environments. Therefore, we propose a real-time digital twin-driven near-miss detection system to facilitate safety management at construction sites. Using advanced stereovision techniques, the system reproduces the construction site as a digital twin model, enabling the real-time 3D monitoring of near-miss events. Additionally, the system incorporates an early warning mechanism to alert workers and managers of potential safety hazards. To demonstrate the effectiveness of the proposed system, a lifting project under various exposure conditions was investigated. The results demonstrate the system's ability to detect and visualize near-misses in three-dimensional space and provide proactive warnings of potential hazards.

Ort, förlag, år, upplaga, sidor
American Society of Civil Engineers (ASCE), 2025. Vol. 151, nr 4, artikel-id 04025021
Nyckelord [en]
Digital twin, Near-miss detection, Real-time three-dimensional (3D) monitoring, Safety management
Nationell ämneskategori
Byggprocess och förvaltning
Identifikatorer
URN: urn:nbn:se:umu:diva-236123DOI: 10.1061/JCEMD4.COENG-15583ISI: 001420997500017Scopus ID: 2-s2.0-85218354963OAI: oai:DiVA.org:umu-236123DiVA, id: diva2:1942955
Tillgänglig från: 2025-03-07 Skapad: 2025-03-07 Senast uppdaterad: 2025-03-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Feng, Kailun

Sök vidare i DiVA

Av författaren/redaktören
Feng, Kailun
Av organisationen
Institutionen för tillämpad fysik och elektronik
I samma tidskrift
Journal of construction engineering and management
Byggprocess och förvaltning

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 102 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf