Time-adjusted performance evaluation (TAPE) of predictive multivariate models for bioprocess data
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.ORCID-id: 0009-0009-7323-192X
Sartorius Stedim Biotech GmbH, Göttingen, Germany.
Sartorius Corporate Research, Brussels, Belgium.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Sartorius Corporate Research, Umeå, Sweden.ORCID-id: 0000-0003-3799-6094
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Journal of Analytical Science & Technology, ISSN 2093-3134, E-ISSN 2093-3371, Vol. 17, nr 1, artikel-id 20Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Cell culture bioprocess data are typically collected across many timepoints and batches, where numerous analytes covary with each other and, critically, with elapsed process time. This time dependence can inflate performance metrics and compromise the validity of multivariate models. We introduce time-adjusted performance evaluation (TAPE), a regression-agnostic validation technique that quantifies and separates time-driven from time-independent predictivity. TAPE pairs leave-one-group-out cross-validation with per-timepoint centering to decompose performance into between-timepoint (time-dependent) and within-timepoint (time-decoupled) parts by comparing predicted and observed deviations from each timepoint mean. Applying TAPE to orthogonal partial least squares models across five Chinese hamster ovary cell culture datasets (three Raman spectroscopy, one metabolomics, and one transcriptomics), several ostensibly strong models’ predictivity was largely explained by timepoint means alone. After removing between-timepoint variation, only models with sample–response relationships independent of time retained good predictivity. For Raman, only models for Raman-active analytes (glucose, lactate) remained predictive, whereas Raman-inactive ones (K+, NH4+) did not. In the omics studies, the models for titer, viable cell density, growth rate, and death rates were predominantly time-driven. By quantifying time’s contribution to model performance, TAPE helps prevent misleadingly good performance metrics and supports more reliable multivariate modeling of time-series bioprocess data.

Ort, förlag, år, upplaga, sidor
Springer, 2026. Vol. 17, nr 1, artikel-id 20
Nyckelord [en]
Bioprocess monitoring, Chinese hamster ovary (CHO) cells, Metabolomics, Model prediction, Model validation, Multivariate calibration, Orthogonal partial least squares (OPLS), Raman spectroscopy, Time-series data, Transcriptomics
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:umu:diva-252262DOI: 10.1186/s40543-026-00538-zISI: 001730658300001Scopus ID: 2-s2.0-105035438112OAI: oai:DiVA.org:umu-252262DiVA, id: diva2:2054029
Tillgänglig från: 2026-04-20 Skapad: 2026-04-20 Senast uppdaterad: 2026-04-20Bibliografiskt granskad

Open Access i DiVA

fulltext(4364 kB)35 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 4364 kBChecksumma SHA-512
79aa829edff1897745a4cd77f2cc087795946ab2876ae9fa4067c3f9a9e80cf63b426cf7f15363bf2a9331a367fff9642f541b1358c6c5d2f0a65d4e35062a04
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Eriksson, AndreasTrygg, JohanAntti, HenrikJonsson, Pär

Sök vidare i DiVA

Av författaren/redaktören
Eriksson, AndreasTrygg, JohanAntti, HenrikJonsson, Pär
Av organisationen
Kemiska institutionen
I samma tidskrift
Journal of Analytical Science & Technology
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 179 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf