Amperometric biosensor for formic acid in air
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkesmedicin. Cranfield Biotechnology Centre, Cranfield University, UK; Department of Chemistry, National Institute for Working Life, Umeå, Sweden.
Cranfield Biotechnology Centre, Cranfield University, UK.
Department of Chemistry, National Institute for Working Life, Umeå, Sweden.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkesmedicin. Department of Chemistry, National Institute for Working Life, Umeå, Sweden.
Visa övriga samt affilieringar
2000 (Engelska)Ingår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 70, nr 1–3, s. 182-187Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The possibility of developing a simple, inexpensive and specific personal passive “real-time” air sampler incorporating a biosensor for formic acid was investigated. The sensor is based on the enzymatic reaction between formic acid and formate dehydrogenase (FDH) with nicotinamide adenine dinucleotide (NAD+) as a co-factor and Meldola's blue as mediator. An effective way to immobilise the enzyme, co-factor and Meldola's blue on screen-printed, disposable, electrodes was found to be in a mixture of glycerol and phosphate buffer covered with a gas-permeable membrane. Steady-state current was reached after 4–15 min and the limit of detection was calculated to be below 1 mg/m3. However, the response decreased by 50% after storage at −15°C for 1 day.

Ort, förlag, år, upplaga, sidor
Elsevier, 2000. Vol. 70, nr 1–3, s. 182-187
Nyckelord [en]
Biosensor, Air monitoring, Formic acid, Gas-permeable membrane, Glycerol
Nationell ämneskategori
Annan miljöbioteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-149303DOI: 10.1016/S0925-4005(00)00566-9ISI: 000090126600026Scopus ID: 2-s2.0-0034324745OAI: oai:DiVA.org:umu-149303DiVA, id: diva2:1220769
Tillgänglig från: 2011-02-04 Skapad: 2018-06-19 Senast uppdaterad: 2023-03-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Sandström, K. J. MattiasTurner, Anthony P. F.
Av organisationen
Yrkesmedicin
I samma tidskrift
Sensors and actuators. B, Chemical
Annan miljöbioteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 789 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf