Umeå University's logo

umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
On patient related factors and their impact on ultrasound-based shear wave elastography of the liver
Umeå University, Faculty of Medicine, Department of Nursing.ORCID iD: 0000-0001-9338-1639
Umeå University, Faculty of Medicine, Department of Nursing.ORCID iD: 0000-0002-1248-5581
2018 (English)In: Ultrasound in Medicine and Biology, ISSN 0301-5629, E-ISSN 1879-291X, Vol. 44, no 8, p. 1606-1615Article in journal (Refereed) Published
Abstract [en]

The aim of the study was to investigate patient-related factors associated with either reliable or poorly reliable measurement results of ultrasound-based shear wave elastography (SWE) of the liver. A total of 188 patients were analyzed prospectively with binary logistic regression using the interquartile range/median as cutoff to define two groups based on reliable and poorly reliable SWE results. SWE results correlated significantly with liver biopsy. Factors associated with reliable SWE results (i.e., no negative impact on measurements) were age, sex, cirrhosis, antiviral and/or cardiovascular medication, smoking habits and body mass index. Factors associated with poorly reliable SWE results were increased skin-to-liver capsule distance (odds ratio = 3.08, 95% confidence interval: 1.70-5.60) and steatosis (odds ratio =2.89, 95% confidence interval: 1.33-6.28). These findings indicate that the interquartile range/median as a quality parameter is useful in avoiding poorly reliable SWE results. How best to examine patients with increased skin-to-liver capsule distance is a matter of some controversy, as the incidences of obesity, diabetes and metabolic syndrome are increasing worldwide; however, our results indicate that reliable SWE results can be obtained in this group of patients by using ultrasound-based SWE. (Email: marie.byenfeldt@umu.se, Marie.byenfeldt@aleris.se ) 

Place, publisher, year, edition, pages
Elsevier, 2018. Vol. 44, no 8, p. 1606-1615
Keywords [en]
Shear wave elastography, Liver fibrosis, Skin-to-liver capsule distance, Interquartile range, Quality parameter, Reliability, Steatosis, Liver biopsy
National Category
Radiology, Nuclear Medicine and Medical Imaging Nursing
Research subject
Radiography
Identifiers
URN: urn:nbn:se:umu:diva-150663DOI: 10.1016/j.ultrasmedbio.2018.03.031ISI: 000436561500004PubMedID: 29735314Scopus ID: 2-s2.0-85046697393OAI: oai:DiVA.org:umu-150663DiVA, id: diva2:1242518
Available from: 2018-08-28 Created: 2018-08-28 Last updated: 2020-03-29Bibliographically approved
In thesis
1. Ultrasound based shear wave elastography of the liver: a non-invasive method for evaluation of liver disease
Open this publication in new window or tab >>Ultrasound based shear wave elastography of the liver: a non-invasive method for evaluation of liver disease
2020 (English)Doctoral thesis, comprehensive summary (Other academic)
Alternative title[sv]
Ultraljudsbaserad shear wave elastografi av levern : en icke-invasiv metod för utvärdering av leversjukdom
Abstract [en]

Background: Detecting liver disease at an early stage is important, given that early intervention decreases the risk of developing cirrhosis and subsequently hepatocellular cancer (HCC). The non-invasive ultrasound-based shear wave elastography (SWE) has been used clinically for a decade to assess liver stiffness. This method is reliable, rapid and can be performed in an outpatient setting without known risks for the patient. However, increased variance in SWE results has been detected, without clear explanation. Factors that affect SWE results needs to be identified. Data are insufficient regarding the reliability of SWE with different body positions and probe pressures. Men have higher SWE results than women, also for unclear reasons. Increasing the reliability of SWE is crucial for understanding how factors such as overweight and obesity, cardiovascular and antiviral medication, age, sex, smoking habits, hepatic steatosis and cirrhosis affect SWE results.

Aims: The overall aim of the studies included in this thesis was to increase the reliability of SWE liver. The specific aims were to investigate patient-related factors associated with increased uncertainty in SWE results. Another aim was to investigate the influence of increased intercostal probe pressure on liver stiffness assessment with SWE liver.  The final aims were to investigate the influence of postural changes, sagittal abdominal diameter (SAD) and skin-to-liver capsule distance (SCD) on SWE results, along with sex-based differences for SWE results and cardiovascular medication.

Methods: All enrolled participants in these studies were consecutive patients with various liver diseases presenting at the radiology department Östersunds Hospital. The patients were examined using SWE liver method at the ultrasound unit between April 2014 and May 2018. Inclusion criteria were that participants be adults (age ≥18 years) who had provided written consent for participating in the study. The exclusion criterion was an inability to communicate. Current guidelines for SWE of the liver were used in the thesis with the following exceptions: In study II, increased intercostal probe pressure was used, and in study III, postural change was used. Study I included 188 patients; study II included 112 patients, and studies III and IV involved 200 patients. The four studies were conducted as cross-sectional and clinical trial, using quantitative methods.

Results: Factors associated with low variance for SWE results were age, sex, and presence of cirrhosis, the use of antiviral and/or cardiovascular medication, smoking habits, and body mass index.  Factors associated with increased uncertainty in SWE results were increased SCD and the presence of steatosis. With increased probe pressure SCD decreased and the quality of shear wave increased. The results showed that the number of required measurements can be reduced. A postural change to left decubitus decreased SCD. For patients with increased SAD and increased SWE result in the supine position, SWE result decreased with a postural change to left decubitus.  The SWE results, SCD and SAD significantly differed between women and men. SWE results was higher in the presence of increased SAD (≥23 cm) among men, but not among women.

Conclusions:  SWE of the liver is a reliable, non-invasive method for diagnosing liver disease. Results in this thesis suggest that for patients with SCD ≥2.5 cm, shear wave measures could be of poor quality and the SWE exam less reliable. In these cases, increased probe pressure may facilitate a reliable SWE exam. With such adjustments in probe pressure, the ultrasound-based SWE method can be superior for examination in patients with overweight or obesity. An effect of SAD ≥23 cm was seen for men with liver fibrosis only, which may explain the higher SWE result for men compared to women. Depending on the severity of liver disease and SAD, a postural change to left decubitus can produce a different outcome. As SAD increased, liver stiffness did, as well. Increased SAD thus is linked to increased liver stiffness, indicating that SAD should be taken into account when performing SWE of the liver.

Place, publisher, year, edition, pages
Umeå: Umeå University, 2020. p. 76
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 2070
Keywords
Anthropometric measurement, diagnostic imaging, elasticity imaging technique, blood supply, BMI, body position, fatty liver, liver disease, hepatic steatosis, liver fibrosis, liver stiffness, obesity, postural change, pressure, probe, sex characteristic, shear wave elastography, skin-to-liver capsule distance, transducer and ultrasonography
National Category
Radiology, Nuclear Medicine and Medical Imaging Gastroenterology and Hepatology Infectious Medicine
Research subject
Radiography
Identifiers
urn:nbn:se:umu:diva-167861 (URN)978-91-7855-197-2 (ISBN)978-91-7855-198-9 (ISBN)
Public defence
2020-04-24, Östersunds sjukhus, Hörsalen Snäckan, Östersund, 09:00 (Swedish)
Opponent
Supervisors
Note

Elektroniskt ISBN saknas i publikationen. 

Available from: 2020-04-03 Created: 2020-03-29 Last updated: 2020-04-08Bibliographically approved

Open Access in DiVA

fulltext(1145 kB)483 downloads
File information
File name FULLTEXT01.pdfFile size 1145 kBChecksum SHA-512
fcf94239dbe5e33f58074f88f6f7bb02f77d3b01003da8d638bd25b946903972b84f926d757b7ae73acde840d295375bec1093054ea2630485637b486d3ae9d2
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Byenfeldt, MarieFransson, Per

Search in DiVA

By author/editor
Byenfeldt, MarieFransson, Per
By organisation
Department of Nursing
In the same journal
Ultrasound in Medicine and Biology
Radiology, Nuclear Medicine and Medical ImagingNursing

Search outside of DiVA

GoogleGoogle Scholar
Total: 483 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 653 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf