The Tensile Strength of Full-Thickness Skin: A Laboratory Study Prior to Its Use as Reinforcement in Parastomal Hernia Repair
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Surgery. Sunderby Research Unit, Department of Surgical and Perioperative Sciences, Umeå University, Luleå, Sweden.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Surgery.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Surgery.
2019 (English)In: Frontiers in Surgery, E-ISSN 2296-875X, Vol. 6, article id 69Article in journal (Refereed) Published
Abstract [en]

Purpose: Parastomal hernia is a common complication of an enterostoma. Current methods of repair have high recurrence rates and are associated with severe complications. Autologous full-thickness skin as reinforcement may reduce the recurrence and complication rates. This study aims to investigates the tensile strength of full-thickness skin; information that is essential if we are to proceed with clinical trials on humans.

Methods: Full-thickness skin samples from 12 donors were tested for tensile strength, as well as the load tolerated by a suture through the skin. Strips of skin were cut out and stretched until breaking point. Sutures were made through skin samples and traction applied until either the tissue or the suture gave way. All done while recording the forces applied using a dynamometer. Identical tests were carried out on commercially available synthetic and biologic graft material for comparison.

Results: The full-thickness skin strips had a median tensile strength of 604 N/cm. This tensile strength was significantly higher than that of the compared materials evaluated in this study. In full-thickness skin, the suture, or tissue endured a median force of 67 N before giving way, which was as high as, or higher than similar sutures through the compared materials.

Conclusions: The tensile strength of full-thickness skin vastly exceeds the physiological forces affecting the abdominal wall, and sutures through skin endure high loads before giving way. The tensile strength of a full-thickness skin graft and the strength of sutures through this material will not limit its use for reinforcement in parastomal hernia repair.

Place, publisher, year, edition, pages
Frontiers Media S.A., 2019. Vol. 6, article id 69
Keywords [en]
full-thickness skin, tensile strength, parastomal hernia, composite mesh, biological mesh
National Category
Surgery
Identifiers
URN: urn:nbn:se:umu:diva-167058DOI: 10.3389/fsurg.2019.00069ISI: 000503267800001Scopus ID: 2-s2.0-85077246496OAI: oai:DiVA.org:umu-167058DiVA, id: diva2:1383986
Funder
Västerbotten County CouncilSwedish Research Council, 2017: 950 834Available from: 2020-01-09 Created: 2020-01-09 Last updated: 2023-03-24Bibliographically approved
In thesis
1. Autologous full-thickness skin graft as reinforcement material in the repair of complex hernias
Open this publication in new window or tab >>Autologous full-thickness skin graft as reinforcement material in the repair of complex hernias
2021 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: Abdominal wall hernia is a common issue in the realm of surgery. Many patients suffering from a hernia require surgical intervention, and over 8000 abdominal hernia repairs are performed each year in Sweden. While most hernia patients undergo successful hernia repair, some types of hernia are associated with high recurrence rates and considerable risk for complications, that in some cases prove fatal. This thesis is based on repair of two such types - giant incisional hernia and parastomal hernia. In many cases, the complications associated with repair of giant incisional hernia and parastomal hernia can be linked to the introduction of foreign mesh material placed in the abdominal wall as reinforcement. Our hypothesis was that the use of autologous full-thickness skin graft instead of synthetic mesh commonly used today would improve the outcome of these repairs.

Aim: The overall aim of this thesis was to investigate the use of autologous full-thickness skin grafts as reinforcement material in the repair of complicated types of hernia.

Results: No significant differences regarding recurrence rate, abdominal muscle strength, and quality-of-life were seen at the 12-month and long-term follow-ups of a randomised controlled multicentre trial comparing the use of full-thickness skin graft with synthetic mesh reinforcement in the repair of giant incisional hernia.Tensile strength and resistance to suture tearing of full-thickness skin were shown to be superior to conventional synthetic and biological meshes. This together with previously performed animal studies allowed us to proceed with the development of a method of parastomal hernia repair with full-thickness skin graft as reinforcement material. This novel method of repair was tested in four pilot patients without any major procedure-related complications. We present a study protocol for a larger randomised controlled multicentre trial to evaluate autologous full-thickness skin graft as reinforcement in parastomal hernia repair.

Conclusions: Autologous full-thickness skin as reinforcement in giant incisional hernia repair produced outcomes similar to synthetic mesh. Its use in parastomal hernia repair is feasible and will be more thoroughly evaluated in a larger trial.

Place, publisher, year, edition, pages
Umeå: Umeå Universitet, 2021. p. 62
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 2157
Keywords
Full-thickness skin graft, Incisional hernia, Parastomal hernia, tensile strength, RCT, abdominal wall strength, quality-of-life, IPOM
National Category
Surgery
Research subject
Surgery
Identifiers
urn:nbn:se:umu:diva-189462 (URN)978-91-7855-664-9 (ISBN)978-91-7855-663-2 (ISBN)
Public defence
2021-12-10, Aulan, Sunderby Sjukhus, Sjukhusvägen 10, Södra Sunderbyn, Luleå, 09:00 (Swedish)
Opponent
Supervisors
Available from: 2021-11-19 Created: 2021-11-10 Last updated: 2022-01-04Bibliographically approved

Open Access in DiVA

fulltext(522 kB)280 downloads
File information
File name FULLTEXT01.pdfFile size 522 kBChecksum SHA-512
fba386daecf25f9054a3ee54413bce25f90fc84863ae9d92ecae67b10d72494f841c00b9096d25929f9d65e8896ccf8fa2653ba17ef2233189167f8c2cf849ec
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Holmdahl, ViktorBackman, OlofGunnarsson, UlfStrigård, Karin

Search in DiVA

By author/editor
Holmdahl, ViktorBackman, OlofGunnarsson, UlfStrigård, Karin
By organisation
Surgery
In the same journal
Frontiers in Surgery
Surgery

Search outside of DiVA

GoogleGoogle Scholar
Total: 280 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 544 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf