Estimating Patient Organ Dosewith Computed Tomography: A Review of Present Methodologyand Required DICOM Information: A Joint Report ofAAPM Task Group 246 and the European Federationof Organizations for Medical Physics (EFOMP)
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Show others and affiliations
2019 (English)Report (Refereed)
Abstract [en]

The purpose of this report is (1) to summarize the current state of the art in estimating organ doses from CT examinations and (2) to outline a road map for standardized reporting of essential parameters necessary for estimation of organ doses from CT imaging in the DICOM standard. To address these purposes, the report includes a comprehensive discussion of (1) the various metrics, concepts, and methods that may be used to achieve estimates of patient organ dose and (2) the DICOM standard for CT.

This Joint Report of the American Association of Physicists in Medicine (AAPM) Task Group 246 and the European Federation of Organizations for Medical Physics (EFOMP) contains three major sections and an appendix. Section 2 (with additional material in the appendix) provides a review of basic CT dosimetry metrics, their uses and limitations in the context of organ dosimetry, and the DICOM information currently associated with parameters that affect CT dose metrics and, consequently, organ dose estimates. Section 3 provides an overview of present and emerging organ dose estimation methods reported in the literature, e.g., for the lens of the eye, breast tissue, colon, and skin. Finally, the report concludes with section 4, which provides a discussion on the sources and magnitudes of uncertainty for different organ dose estimation methods.

Ongoing efforts to facilitate routine standardized estimation of patient organ doses from CT are dependent, in large part, on the availability of the DICOM Radiation Dose Structured Report (RDSR), which provides a host of information pertinent to radiation dose calculations. This report, therefore, includes detailed information on DICOM header content in CT images and how it can be used in organ dose estimation. The RDSR markedly expands the abilities of the clinical medical physicist to estimate doses at the patient, device, and protocol level

Place, publisher, year, edition, pages
Alexandria,Virginia, USA: American Association of Physicists in Medicine , 2019. , p. 46
Series
AAPM report, ISSN 0271-7344
National Category
Other Physics Topics
Research subject
radiation physics
Identifiers
URN: urn:nbn:se:umu:diva-171579DOI: 10.37206/190ISBN: 978-1-936366-72-9 (electronic)OAI: oai:DiVA.org:umu-171579DiVA, id: diva2:1435507
Available from: 2020-06-05 Created: 2020-06-05 Last updated: 2020-06-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Andersson, Jonas

Search in DiVA

By author/editor
Andersson, Jonas
By organisation
Radiation Physics
Other Physics Topics

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 850 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf