Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Indoor and outdoor nanoparticle concentrations in an urban background area in northern Sweden: The NanoOffice study
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Avdelningen för hållbar hälsa. Institute of Family Medicine and Public Health, Faculty of Medicine, University of Tartu, Tartu, Estonia.ORCID-id: 0000-0002-7965-9451
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Avdelningen för hållbar hälsa.
2021 (engelsk)Inngår i: Environments, E-ISSN 2076-3298, Vol. 8, nr 8, artikkel-id 75Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In recent years, nanoparticles (NPs) have received much attention due to their very small size, high penetration capacity, and high toxicity. In urban environments, combustion-formed nanoparticles (CFNPs) dominate in particle number concentrations (PNCs), and exposure to those particles constitutes a risk to human health. Even though fine particles (<2.5 µm) are regularly monitored, information on NP concentrations, both indoors and outdoors, is still limited. In the NanoOffice study, concentrations of nanoparticles (10–300 nm) were measured both indoors and outdoors with a 5-min time resolution at twelve office buildings in Umeå. Measurements were taken during a one-week period in the heating season and a one-week period in the non-heating season. The measuring equipment SMPS 3938 was used for indoor measurements, and DISCmini was used for outdoor measurements. The NP concentrations were highest in offices close to a bus terminal and lowest in offices near a park. In addition, a temporal effect appeared, usually with higher concentrations of nanoparticles found during daytime in the urban background area, whereas considerably lower nanoparticle concentrations were often present during nighttime. Infiltration of nanoparticles from the outdoor air into the indoor air was also common. However, the indoor/outdoor ratios (I/O ratios) of NPs showed large variations between buildings, seasons, and time periods, with I/O ratios in the range of 0.06 to 0.59. The reasons for high indoor infiltration rates could be NP emissions from adjacent outdoor sources. We could also see particle growth since the indoor NPs were, on average, almost twice as large as the NPs measured outdoors. Despite relatively low concentrations of NPs in the urban background air during nighttime, they could rise to very high daytime concentrations due to local sources, and those particles also infiltrated the indoor air.

sted, utgiver, år, opplag, sider
MDPI, 2021. Vol. 8, nr 8, artikkel-id 75
Emneord [en]
Air pollution, Air quality, Health, Indoor air, Nanoparticles, Toxicity
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-187007DOI: 10.3390/environments8080075ISI: 000689053200001Scopus ID: 2-s2.0-85113134072OAI: oai:DiVA.org:umu-187007DiVA, id: diva2:1589310
Forskningsfinansiär
Swedish Research Council Formas, 2015-01557Tilgjengelig fra: 2021-08-31 Laget: 2021-08-31 Sist oppdatert: 2023-09-05bibliografisk kontrollert

Open Access i DiVA

fulltext(3359 kB)98 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 3359 kBChecksum SHA-512
0c67eb84d1f0d1a7b9705f8b5ab6092160d57a0394a0fe77eb0937e01d1b3a086d2043690c884041ea5c7fc6553d2877d5631dbf3c3ea6bf930c1ff0ad0c1d42
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Orru, HansHagenbjörk-Gustavsson, Annika

Søk i DiVA

Av forfatter/redaktør
Orru, HansHagenbjörk-Gustavsson, Annika
Av organisasjonen
I samme tidsskrift
Environments

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 98 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 186 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf