Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Reliability and validity of visual analysis of [18F]FE-PE2I PET/CT in early Parkinsonian disease
Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB). Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Neurovetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).ORCID-id: 0000-0002-3731-3612
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Nuclear medicine communications, ISSN 0143-3636, E-ISSN 1473-5628, Vol. 44, nr 5, s. 397-406Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: [18F]FE-PE2I (FE-PE2I) is a new radiotracer for dopamine transporter (DAT) imaging with PET. The aim of this study was to evaluate the visual interpretation of FE-PE2I images for the diagnosis of idiopathic Parkinsonian syndrome (IPS). The inter-rater variability, sensitivity, specificity, and diagnostic accuracy for visual interpretation of striatal FE-PE2I compared to [123I]FP-CIT (FP-CIT) single-photon emission computed tomography (SPECT) was evaluated.

Methods: Thirty patients with newly onset parkinsonism and 32 healthy controls with both an FE-PE2I and FP-CIT were included in the study. Four patients had normal DAT imaging, of which three did not fulfil the IPS criteria at the clinical reassessment after 2 years. Six raters evaluated the DAT images blinded to the clinical diagnosis, interpreting the image as being ‘normal’ or ‘pathological’, and assessed the degree of DAT-reduction in the caudate and putamen. The inter-rater agreement was assessed with intra-class correlation and Cronbach’s α. For calculation of sensitivity and specificity, DAT images were defined as correctly classified if categorized as normal or pathological by ≥4/6 raters.

Results: The overall agreement in visual evaluation of the FE-PE2I- and FP-CIT images was high for the IPS patients (α = 0.960 and 0.898, respectively), but lower in healthy controls (FE-PE2I: α = 0.693, FP-CIT: α = 0.657). Visual interpretation gave high sensitivity (both 0.96) but lower specificity (FE-PE2I: 0.86, FP-CIT: 0.63) with an accuracy of 90% for FE-PE2I and 77% for FP-CIT.

Conclusion: Visual evaluation of FE-PE2I PET imaging demonstrates high reliability and diagnostic accuracy for IPS.

Ort, förlag, år, upplaga, sidor
Wolters Kluwer, 2023. Vol. 44, nr 5, s. 397-406
Nyckelord [en]
[18F]FE-PE2I PET/computed tomography, diagnostic accuracy, early disease, Parkinson’s disease, PET
Nationell ämneskategori
Radiologi och bildbehandling
Forskningsämne
radiologi; neurologi
Identifikatorer
URN: urn:nbn:se:umu:diva-206635DOI: 10.1097/mnm.0000000000001679ISI: 000970601600009PubMedID: 36862448Scopus ID: 2-s2.0-85152168200OAI: oai:DiVA.org:umu-206635DiVA, id: diva2:1750429
Forskningsfinansiär
Region VästerbottenUmeå universitetParkinsonfondenTillgänglig från: 2023-04-13 Skapad: 2023-04-13 Senast uppdaterad: 2024-07-02Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

af Bjerkén, SaraAxelsson, JanLarsson, AnneFlygare, CarolinaStrandberg, SaraEriksson, LindaBäckström, David C.Jakobson Mo, Susanna

Sök vidare i DiVA

Av författaren/redaktören
af Bjerkén, SaraAxelsson, JanLarsson, AnneFlygare, CarolinaStrandberg, SaraEriksson, LindaBäckström, David C.Jakobson Mo, Susanna
Av organisationen
Institutionen för integrativ medicinsk biologi (IMB)NeurovetenskaperRadiofysikUmeå centrum för funktionell hjärnavbildning (UFBI)Diagnostisk radiologi
I samma tidskrift
Nuclear medicine communications
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 507 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf