Umeå University's logo

umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Enhancing computation speed and accuracy in deep image prior-based parameter mapping
Umeå University, Faculty of Medicine, Department of Diagnostics and Intervention.ORCID iD: 0000-0002-0200-6567
Umeå University, Faculty of Science and Technology, Department of Computing Science. Umeå University, Faculty of Medicine, Department of Diagnostics and Intervention.ORCID iD: 0000-0003-4685-379X
Umeå University, Faculty of Science and Technology, Department of Computing Science.ORCID iD: 0000-0001-7119-7646
Umeå University, Faculty of Medicine, Department of Diagnostics and Intervention.ORCID iD: 0000-0002-0532-232X
2025 (English)In: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 94, no 6, p. 2654-2667Article in journal (Refereed) Published
Abstract [en]

Purpose: To make Deep Image Prior (DIP)-based parameter mapping faster, more accurate, and suitable for clinical applications, with added support for multislice and 3D datasets.

Methods: DIP leverages the inherent structure of an untrained image generator to address various inverse imaging tasks, including denoising. In this study, we enhance DIP-based denoising for parameter mapping with warm-start across neighboring image slices and different patient subjects. This approach leverages spatial similarity to reduce computation time. Additionally, we introduce an early-stopping criterion that selects the denoising level based on MRI signal noise. We further investigate uncertainty calibration through dropout probability tuning to address issues with miscalibrated uncertainty estimates from Monte Carlo dropout. Furthermore, we explore reducing computation time by tuning learning rates and network complexity.

Results: We show that reusing image generator weights with warm-start significantly accelerates the denoising of large datasets, reducing computation time by 78% to 95% across various tasks. The early stopping approach proved effective, eliminating the need to manually select the number of optimization steps. Dropout probability tuning helps mitigate the issue of miscalibrated uncertainty, though further refinements are necessary, particularly to achieve better calibration on a per-pixel level. Additionally, tuning learning rates and network complexity provided valuable insights into optimizing the model for different tasks.

Conclusion: The proposed developments enable DIP-based parameter mapping to become faster, more accurate, and, consequently, more practical and scalable for clinical applications involving larger datasets.

Place, publisher, year, edition, pages
John Wiley & Sons, 2025. Vol. 94, no 6, p. 2654-2667
Keywords [en]
deep image Prior, denoising, parameter mapping, quantitative MRI, uncertainty estimation
National Category
Medical Imaging
Identifiers
URN: urn:nbn:se:umu:diva-242758DOI: 10.1002/mrm.30630ISI: 001525554400001PubMedID: 40638859Scopus ID: 2-s2.0-105010593607OAI: oai:DiVA.org:umu-242758DiVA, id: diva2:1987735
Funder
Swedish Research Council, 2019-0432Cancerforskningsfonden i Norrland, AMP 18-912Lions Cancerforskningsfond i Norr, LP 18-2182Lions Cancerforskningsfond i Norr, LP 22-2319Lions Cancerforskningsfond i Norr, LP 24-2367Available from: 2025-08-07 Created: 2025-08-07 Last updated: 2025-10-08Bibliographically approved
In thesis
1. Noise reduction and uncertainty estimation in quantitative magnetic resonance imaging
Open this publication in new window or tab >>Noise reduction and uncertainty estimation in quantitative magnetic resonance imaging
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Alternative title[sv]
Brusreducering och osäkerhetsuppskattning i kvantitativ magnetresonanstomografi
Abstract [en]

Quantitative magnetic resonance imaging (qMRI) is a subset of MRI that moves beyond qualitative image interpretation towards more objective and reproducible quantification of tissue parameters, a process referred to as parameter mapping. In cancer imaging, this capability has the potential to assist with characterizing tumors, monitoring treatment response, and comparing scans both over time and across different scanners or imaging sites. This thesis addresses the problem of uncertainty in parameter mapping. This is done by developing methods that both reduce uncertainty and estimate the uncertainty that remains, two important components for advancing the clinical reliability of qMRI. The first component, reducing uncertainty, focuses on reducing noise in the parameter maps. In this thesis, we propose methods that apply denoising priors to stabilize the parameter mapping process. The second component, estimating the remaining uncertainty, aims to quantify what uncertainty remains after denoising has been applied. This is achieved through uncertainty estimation, providing a more complete picture of the results.

Paper I presents a method for T1 mapping that combines an explicit denoising prior, in the form of total variation (TV) regularization, together with uncertainty estimation using Markov chain Monte Carlo (MCMC) sampling. The strength of the TV prior is selected in a data-driven way which reduces the requirement of manual tuning. This approach produces denoised parameter maps with reduced uncertainty and meaningful uncertainty estimates. Remaining challenges include the computational burden and the need to carefully manage prior-induced biases.

Paper II introduces an alternative to the method in Paper I. Instead of using an explicit prior, it exploits Deep Image Prior (DIP), which utilizes the structure of an untrained convolutional neural network to impose an implicit prior. This is implemented with Monte Carlo dropout, a simple approach to approximate Bayesian inference for uncertainty estimation. The method is easy to implement and denoises the tissue parameters T1, T2, and ADC. However, the results reveal that uncertainty calibration becomes more challenging, and the computation time remains too long for practical clinical use.

Paper III improves the DIP method from Paper II by addressing long computation times and difficulties in uncertainty calibration. To reduce computation times, we introduce warm-start initialization, which leverages information from both neighboring image slices and different subjects to accelerate parameter mapping. To improve calibration, we systematically tune MC dropout to reduce miscalibration. In addition, a data-driven early stopping criterion is proposed to automatically set the denoising level, removing the need for manual tuning. Together, these changes make the DIP method faster, better calibrated, and more clinically usable.

Paper IV investigates further improvements of the DIP method towards more advanced qMRI models, specifically evaluated with Patlak-based estimation of pharmacokinetic parameters in DCE-MRI. This study evaluates the feasibility of this approach by comparing parameter maps with and without the DIP method applied. Preliminary results show substantial noise reduction and improved feature representation. Remaining challenges include prior-induced biases that require further refinement.

In summary, this thesis addresses uncertainty in qMRI by focusing on two key components: reducing uncertainty through denoising and estimating the remaining uncertainty. These aspects are investigated using two fundamentally different strategies: one based on explicit denoising with robust Bayesian inference using MCMC (Paper I), and one based on implicit denoising combined with approximate Bayesian inference (Papers II-IV). The four included studies develop and refine these strategies to overcome practical limitations and enhance applicability. By evaluating their respective strengths and weaknesses, the work provides insight into how methodological choices affect accuracy, uncertainty, and computational feasibility. These contributions aim to support the development of qMRI as a more trustworthy and reproducible tool in cancer imaging and beyond.

Place, publisher, year, edition, pages
Umeå: Umeå University, 2025. p. 78
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 2376
Keywords
Quantitative MRI, Denoising, Uncertainty estimation, Markov chain Monte Carlo, Deep Image Prior
National Category
Radiology and Medical Imaging
Research subject
radiation physics
Identifiers
urn:nbn:se:umu:diva-244020 (URN)978-91-8070-760-2 (ISBN)978-91-8070-759-6 (ISBN)
Public defence
2025-10-03, Triple Helix, Universitetsledningshuset (plan 3), Umeå, 09:00 (English)
Opponent
Supervisors
Available from: 2025-09-12 Created: 2025-09-09 Last updated: 2025-09-11Bibliographically approved

Open Access in DiVA

fulltext(3232 kB)71 downloads
File information
File name FULLTEXT02.pdfFile size 3232 kBChecksum SHA-512
a51bfaae8309749a5cd02378564bc8f0267005ef45213e110442db6c710f15a03c70d96221673aca7b6472a08f9167b11a1c6f6ffa1522bf619d565b5cc8f49d
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Hellström, MaxKurtser, PolinaLöfstedt, TommyGarpebring, Anders

Search in DiVA

By author/editor
Hellström, MaxKurtser, PolinaLöfstedt, TommyGarpebring, Anders
By organisation
Department of Diagnostics and InterventionDepartment of Computing Science
In the same journal
Magnetic Resonance in Medicine
Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 97 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 514 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf