Influence of lead apron shielding on absorbed doses from cone-beam computed tomography
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi. Digital Diagnostic Center, Kaiser-Joseph-Str. 263, 79098 Freiburg im Breisgau, Germany. Department of Radiology, Nihon University School of Dentistry, Tokyo, Japan.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 175, nr 1, s. 110-117Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO® phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500®, ProMax® 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax® 3D with shielding, the ED was 149 µSv, and for the examination protocol without shielding 148 µSv (SD = 0.31 µSv). For the CS 9500®, the ED was 88 and 86 µSv (SD = 0.95 µSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam.

Ort, förlag, år, upplaga, sidor
2017. Vol. 175, nr 1, s. 110-117
Nationell ämneskategori
Annan fysik
Forskningsämne
radiofysik
Identifikatorer
URN: urn:nbn:se:umu:diva-126833DOI: 10.1093/rpd/ncw275ISI: 000404476500014PubMedID: 27664428Scopus ID: 2-s2.0-85021313660OAI: oai:DiVA.org:umu-126833DiVA, id: diva2:1037497
Tillgänglig från: 2016-10-16 Skapad: 2016-10-16 Senast uppdaterad: 2023-03-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Rottke, DennisAndersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Rottke, DennisAndersson, Jonas
Av organisationen
Institutionen för odontologiRadiofysik
I samma tidskrift
Radiation Protection Dosimetry
Annan fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 396 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf