Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 39, s. 67-72Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice. The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided. If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required.

Ort, förlag, år, upplaga, sidor
2017. Vol. 39, s. 67-72
Nyckelord [en]
Cone-beam CT, Diagnostic radiology, Ionizing radiation, Quality control, Radiation protection
Nationell ämneskategori
Annan fysik
Forskningsämne
radiofysik
Identifikatorer
URN: urn:nbn:se:umu:diva-137460DOI: 10.1016/j.ejmp.2017.05.069ISI: 000405493200009PubMedID: 28602688Scopus ID: 2-s2.0-85020270248OAI: oai:DiVA.org:umu-137460DiVA, id: diva2:1119081
Tillgänglig från: 2017-07-03 Skapad: 2017-07-03 Senast uppdaterad: 2023-03-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Andersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Jonas
Av organisationen
Radiofysik
I samma tidskrift
Physica medica (Testo stampato)
Annan fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 449 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf