The dosimetric impact of including the patient table in CT dose estimates
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 62, nr 23, s. 538-547Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The purpose of this study was to evaluate the dosimetric impact of including the patient table in Monte Carlo CT dose estimates for both spiral scans and scan projection radiographs (SPR). CT scan acquisitions were simulated for a Siemens SOMATOM Force scanner (Siemens Healthineers, Forchheim, Germany) with and without a patient table present. An adult male, an adult female and a pediatric female voxelized phantom were simulated. The simulated scans included tube voltages of 80 and 120 kVp. Spiral scans simulated without a patient table resulted in effective doses that were overestimated by approximately 5 % compared to the same simulations performed with the patient table present. Doses in selected individual organs (breast, colon, lung, red bone marrow and stomach) were overestimated by up to 8 %. Effective doses from SPR acquired with the X-ray tube stationary at 6 o'clock (posterior-anterior) were overestimated by 14-23 % when the patient table was not included, with individual organ dose discrepancies (breast, colon, lung red bone marrow and stomach) all exceeding 13%. The reference entrance skin dose to the back were in this situation overestimated by 6-15 %. These results highlight the importance of including the patient table in patient dose estimates for such scan situations.

Ort, förlag, år, upplaga, sidor
2017. Vol. 62, nr 23, s. 538-547
Nyckelord [en]
Monte Carlo, computed tomography, dosimetry, patient dose, patient table
Nationell ämneskategori
Annan fysik
Forskningsämne
radiofysik
Identifikatorer
URN: urn:nbn:se:umu:diva-140510DOI: 10.1088/1361-6560/aa9259ISI: 000425833200001PubMedID: 28994662Scopus ID: 2-s2.0-85038213087OAI: oai:DiVA.org:umu-140510DiVA, id: diva2:1148874
Tillgänglig från: 2017-10-12 Skapad: 2017-10-12 Senast uppdaterad: 2023-03-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Andersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Jonas
Av organisationen
Radiofysik
I samma tidskrift
Physics in Medicine and Biology
Annan fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 326 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf