Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0001-7539-2262
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: International Journal of Radiation Oncology, Biology, Physics, ISSN 0360-3016, E-ISSN 1879-355X, Vol. 100, nr 2, s. 317-324Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.

Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution.

Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (−0.5, 0.5) for all investigated plan quality measures.

Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%.

Ort, förlag, år, upplaga, sidor
Elsevier, 2018. Vol. 100, nr 2, s. 317-324
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-142319DOI: 10.1016/j.ijrobp.2017.10.021ISI: 000423097500011PubMedID: 29229326Scopus ID: 2-s2.0-85041293743OAI: oai:DiVA.org:umu-142319DiVA, id: diva2:1160459
Tillgänglig från: 2017-11-27 Skapad: 2017-11-27 Senast uppdaterad: 2024-07-02Bibliografiskt granskad
Ingår i avhandling
1. Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
Öppna denna publikation i ny flik eller fönster >>Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
2019 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Kvalitetssäkring av magnetisk resonanstomografi (MRI/MRT) inom radioterapi
Abstract [en]

The use of Magnetic Resonance Imaging (MRI) in the radiotherapy (RT) treatment planning workflow is increasing. MRI offers superior soft-tissue contrast compared to Computed Tomography (CT) and therefore improves the accuracy in target volume definitions. There are, however concerns with inherent geometric distortions from system- (gradient nonlinearities and main magnetic field inhomogeneities) and patient-related sources (magnetic susceptibility effect and chemical shift). The lack of clearly defined quality assurance (QA) procedures has also raised questions on the ability of current QA protocols to detect common image quality degradations under radiotherapy settings. To fully implement and take advantage of the benefits of MRI in radiotherapy, these concerns need to be addressed.

In Papers I and II, the dosimetric impact of MR distortions was investigated. Patient CTs (CT) were deformed with MR distortion vector fields (from the residual system distortions after correcting for gradient nonlinearities and patient-induced susceptibility distortions) to create distorted CT (dCT) images. Field parameters from volumetric modulated arc therapy (VMAT) treatment plans initially optimized on dCT data sets were transferred to CT data to compute new treatment plans. Data from 19 prostate and 21 head and neck patients were used for the treatment planning. The dCT and CT treatment plans were compared to determine the impact of distortions on dose distributions. No clinically relevant dose differences between distorted CT and original CT treatment plans were found. Mean dose differences were < 1.0% and < 0.5% at the planning target volume (PTV) for the head and neck, and prostate treatment plans, respectively. 

Strategies to reduce geometric distortions were also evaluated in Papers I and II. Using the vendor-supplied gradient non-linearity correction algorithm reduced overall distortions to less than half of the original value. A high acquisition bandwidth of 488 Hz/pixel (Paper I) and 488 Hz/mm (Paper II) kept the mean geometric distortions at the delineated structures below 1 mm. Furthermore, a patient-specific active shimming method implemented in Paper II significantly reduced the number of voxels with distortion shifts > 2 mm from 15.4% to 2.0%.

B0 maps from patient-induced magnetic field inhomogeneities obtained through direct measurements and by simulations that used MR-generated synthetic CT (sCT) data were compared in Paper III. The validation showed excellent agreement between the simulated and measured B0 maps.

In Paper IV, the ability of current QA methods to detect common MR image quality degradations under radiotherapy settings were investigated. By evaluating key image quality parameters, the QA protocols were found to be sensitive to some of the introduced degradations. However, image quality issues such as those caused by RF coil failures could not be adequately detected.

In conclusion, this work has shown the feasibility of using MRI data for radiotherapy treatment planning as distortions resulted in a dose difference of less than 1% between distorted and undistorted images. The simulation software can be used to produce accurate B0 maps, which could then be used as the basis for the effective correction of patient-induced field inhomogeneity distortions and for the QA verification of sCT data. Furthermore, the analysis of the strengths and weaknesses in current QA tools for MRI in RT contribute to finding better methods to efficiently identify image quality errors.

Ort, förlag, år, upplaga, sidor
Umeå: Medical Faculty, Umeå University, 2019. s. 78
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 2057
Nyckelord
magnetic resonance imaging, MRI, radiotherapy, RT, geometric distortions, magnetic susceptibility, B0 maps, quality assurance
Nationell ämneskategori
Radiologi och bildbehandling
Forskningsämne
radiofysik
Identifikatorer
urn:nbn:se:umu:diva-164771 (URN)978-91-7855-130-9 (ISBN)
Disputation
2019-11-29, Hörsal 933, byggnad 3, Norrlands universitetssjukhus, Umeå, 09:00 (Engelska)
Opponent
Handledare
Forskningsfinansiär
Cancerforskningsfonden i Norrland, AMP 18-905
Anmärkning

PhD Study of Author partially funded by The Schlumberger Faculty for the Future Foundation (FFTF)

Tillgänglig från: 2019-11-08 Skapad: 2019-10-31 Senast uppdaterad: 2024-07-02Bibliografiskt granskad

Open Access i DiVA

fulltext(1385 kB)521 nedladdningar
Filinformation
Filnamn FULLTEXT03.pdfFilstorlek 1385 kBChecksumma SHA-512
47d43ea9c79949872f3831c89bb093cbef518a9e386975be7bf309cc2402dd1747cc98802aa101eb7ca163941ef4b8035edb65164cb50144681412a0a4194222
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Adjeiwaah, MaryBylund, MikaelLundman, Josef A.Thellenberg Karlsson, CamillaJonsson, Joakim H.Nyholm, Tufve

Sök vidare i DiVA

Av författaren/redaktören
Adjeiwaah, MaryBylund, MikaelLundman, Josef A.Thellenberg Karlsson, CamillaJonsson, Joakim H.Nyholm, Tufve
Av organisationen
RadiofysikOnkologi
I samma tidskrift
International Journal of Radiation Oncology, Biology, Physics
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 527 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1465 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf