Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Lower Jaw Movements Measured by Optoelectronic Movement Recording: A pilot study
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
2018 (Engelska)Självständigt arbete på avancerad nivå (yrkesexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

Due to the complex nature of jaw movements, three-dimensional (3D) movement recording provide information about the jaw movement capacity. The aim of the present report was to test the reliability of measuring lower jaw movements using a 3D movement recording system and to calculate the lower jaw movement volume.

Lower jaw movements, recorded by 3D optoelectronic movement analysis system (MacReflex®) was compared with reference values from a digital caliper. Pre-tests were performed to develop a software to calculate the lower jaw movements in separate dimensions and its volume. Pilot tests with two test persons followed to register the lower jaw movements and calculate lower jaw movement volume.

The results indicate low reliability of lower jaw movements measured by movement recording system compared with reference values from digital caliper, reflected by delta values (D = max-min). The values from the movement recording system indicate high variability reflected by higher levels of standard deviation for movement recorded values compared with digital caliper and by percentage values calculated from the differences between mean values of movement recording and digital caliper. The calculated lower jaw movement volume was 10.3 cm3 and 17.2 cm3 for the test persons, respectively.

Conclusively, the results imply that further testing of the method is needed with larger series and test-retest reliability analysis to evaluate the possibility to improve accuracy of tracing jaw movements with recording device. The 3D-movement recording system together with the software could be used for calculation of lower jaw movement volume but its accuracy could not be validated.

Ort, förlag, år, upplaga, sidor
2018. , s. 25
Nyckelord [en]
Lower Jaw Movements. Optoelectronic Movement Recording. Mandibular movement. Volume.
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:umu:diva-143860OAI: oai:DiVA.org:umu-143860DiVA, id: diva2:1173036
Externt samarbete
Helena Grip; VLL
Utbildningsprogram
Tandläkarprogrammet
Presentation
2017-10-16, Umeå Universitet, Umeå, 13:21
Handledare
Examinatorer
Tillgänglig från: 2018-01-11 Skapad: 2018-01-11 Senast uppdaterad: 2018-01-11Bibliografiskt granskad

Open Access i DiVA

fulltext(788 kB)731 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 788 kBChecksumma SHA-512
c3118a05809be44645cb76c93303e2f418616cfa6b19abe47abfa220a9b087dcefebee125f01e005c5be8af6f46935f31fc3856956336970209fb0d423093f75
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Wänman, Magnus
Av organisationen
Institutionen för odontologi
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 733 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 408 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf