Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-6th-edition.csl
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Improving the UNC passive aerosol sampler model based on comparison with commonly used aerosol sampling methods
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.ORCID-id: 0000-0003-1227-6859
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Yrkes- och miljömedicin.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Annals of Work Exposures and Health, ISSN 2398-7308 , E-ISSN 2398-7316 , Vol. 62, nr 3, s. 328-338Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of this study was to evaluate, and possibly improve, the UNC sampler for stationary sampling in a working environment.

Methods: Sampling was carried out at 8-h intervals during 24 h in four locations in an open pit mine with UNC samplers, respirable cyclones, PM10 and PM2.5 impactors, and an aerodynamic particle sizer (APS). The wind was minimal. For quantification, two modifications of the UNC sampler analysis model, UNC sampler with hybrid model and UNC sampler with area factor, were compared with the original one, UNC sampler with mesh factor derived from wind tunnel experiments. The effect of increased resolution for the microscopic imaging was examined.

Results: Use of the area factor and a higher resolution eliminated the underestimation for PM10 and PM2.5. The model with area factor had the overall lowest deviation versus the impactor and the cyclone. The intraclass correlation (ICC) showed that the UNC sampler had a higher precision and better ability to distinguish between different exposure levels compared to the cyclone (ICC: 0.51 versus 0.24), but lower precision compared to the impactor (PM10: 0.79 versus 0.99; PM2.5: 0.30 versus 0.45). The particle size distributions as calculated from the different UNC sampler analysis models were visually compared with the distributions determined by APS. The distributions were obviously different when the UNC sampler with mesh factor was used but came to a reasonable agreement when the area factor was used.

Conclusions: High resolution combined with a factor based on area only, results in no underestimation of small particles compared to impactors and cyclones and a better agreement with the APS’s particle size distributions. The UNC sampler had lower precision than the impactors, but higher than the respirable cyclone. The UNC sampler with area factor could be used for PM2.5, PM10 and respirable fraction measurements in this working environment without wind.

Ort, förlag, år, upplaga, sidor
Oxford University Press, 2018. Vol. 62, nr 3, s. 328-338
Nyckelord [en]
inorganic dust, mesh factor, PM10, PM2.5, respirable fraction, UNC passive aerosol sampler, working environment
Nationell ämneskategori
Arbetsmedicin och miljömedicin Fysik
Identifikatorer
URN: urn:nbn:se:umu:diva-145698DOI: 10.1093/annweh/wxx110ISI: 000432804600008PubMedID: 29300818Scopus ID: 2-s2.0-85050719053OAI: oai:DiVA.org:umu-145698DiVA, id: diva2:1190434
Tillgänglig från: 2018-03-14 Skapad: 2018-03-14 Senast uppdaterad: 2024-07-02Bibliografiskt granskad
Ingår i avhandling
1. Measuring occupational dust exposure with a passive sampler
Öppna denna publikation i ny flik eller fönster >>Measuring occupational dust exposure with a passive sampler
2018 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Mätning av dammexponering i arbetslivet med en passiv provtagare
Abstract [en]

Objectives: In a working environment it is important to measure dust exposure to evaluate possible health issues. Passive sampling could be an alternative to active sampling with pumps when measuring occupational dust exposure. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). Promising results for the applicability of this type of passive sampler have been shown for particles above 2.5 μm, but indicate large underestimations for PM2.5. The overall purpose was to develop more knowledge about the UNC sampler and the possibility of using it for personal sampling of occupational dust exposure. Specific aims were to: evaluate and possibly improve the UNC sampler for stationary sampling in a working environment and compare the UNC sampler with commonly used aerosol sampling methods; characterise the impairment in performance of the UNC sampler concentrations when decreasing the number of images in order to achieve lowered costs and decreased analysis time, and; establish if the UNC sampler could be used for personal sampling in the working environment.

Methods: All sample collection in this thesis was performed in an open pit mine. For stationary sampling UNC samplers, impactors (PM10 and PM2.5), respirable cyclones, and an aerodynamic particle sizer were used. For personal sampling UNC samplers and respirable cyclones were used. The analysis of the UNC sampler consisted of two parts, the microscopic imaging of the deposited particles and the analysis model for calculations of mass concentration.

Results: In the first pilot study the UNC sampler with its original analysis model was used. Compared to PM10 impactor concentrations the UNC sampler showed 58% of the impactor results and 35% of PM2.5 impactor results. The second study showed that a new analysis model and use of higher microscopy resolution led to no underestimation compared to PM2.5 impactors, while PM10 improved but not to the same extent. A higher precision was also achieved compared to the respirable cyclone (intraclass correlation: 0.51 versus 0.24). When UNC sampler particle size distributions were compared to aerodynamic particle sizer data, they showed similar distributions for the new analysis model, but deviating distributions for the original analysis model. In the third study the number of images needed from the microscopic imaging process was reduced. Reducing the number of images analysed from 60 to 10 increased the coefficient of variation from 36% to 37% for respirable fraction. Finally, the UNC sampler was used for personal sampling in a working environment for the first time. Again, the particle size distribution of the new UNC sampler analysis model was reasonable, while the distribution of the original model was not. There were almost exclusively particles of mineral origin on the UNC sampler, but compared to the respirable cyclone, the UNC sampler overestimated the particle concentrations approximately 30 times.

Conclusions: The new analysis model for the UNC sampler enables stationary passive sampling of dust exposure of mineral character. Quicker microscopic image analysis, by reducing the number of images for mass concentration calculations to ten, results in a negligible loss in precision. Personal sampling with the UNC sampler showed deposited particles of reasonable size distribution and obviously originating from the working environment, but with severe overestimation of the mass concentration. Thus, the UNC sampler with the new analysis model can be used for stationary sampling in a mine, but is not yet ready for personal sampling.

Abstract [sv]

Vi utsätts för damm hela tiden, däremot är inte allt damm skadligt. Skadligt damm som vi utsätts för på grund av arbetet är viktigt att mäta för att utreda olika hälsorisker. För att mäta damm i arbetsmiljön används idag pumpad provtagning. Pumpad provtagning innebär att en avskiljare suger in damm, med hjälp av en pump, på ett filter som vägs. Två exempel på avskiljare som gör att partiklar av intresse samlas upp är en impaktor och en cyklon. En impaktor fungerar på så sätt att dammpartiklarna som är för stora krockar med en yta, medan resten landar på filtret. Cyklonen fungerar nästan på samma sätt, men den baseras på en luftvirvel som skiljer på dammpartiklarna utifrån storlek. Ett alternativ till pumpad provtagning av damm i arbetsmiljön skulle kunna vara passiv provtagning. Passiv provtagning innebär att en strömkälla inte behövs för att provta. En specifik passiv provtagare, University of North Carolina passiv partikelprovtagare, studerades. Lovande resultat har redan setts med den passiva provtagaren för partiklar större än 2.5 μm, men den har visat alltför låga koncentrationer för de lägre partikelstorlekarna. Målet var att inhämta mer kunskap om denna passiva provtagare och undersöka om den kan användas för personburen provtagning i arbetsmiljön. Arbetsmiljön som valdes för att undersöka den passiva provtagaren i var en gruva (dagbrott). Då provtagaren aldrig använts i gruvan tidigare togs även impaktorer, cykloner och andra typer av provtagare med som det redan finns kunskap om och som redan blivit testade. Mätningarna utfördes på två olika vis, både på olika platser i gruvan och även på olika personer. För att utvärdera resultatet av den passiva provtagaren tas bilder på dammet med ett avancerat mikroskop. Informationen från bilderna görs sedan om till koncentrationen av dammet för att kunna jämföra detta med de andra provtagarna.Efter de första mätningarna visade den passiva provtagaren lägre koncentrationer jämfört med impaktorerna. Då tidigare studier visat att den passiva provtagaren stämde bra överens för större partiklar gjordes fler mätningar. Från den andra vändan av mätningar upptäcktes återigen samma fenomen. Det som inte hade tagits hänsyn till i teorin för den passiva provtagaren var att den fungerar annorlunda då det är vindstilla. Överallt i gruvan där det hade mätts var det vindstilla. Efter att ha ändrat modellen till att ta hänsyn till att det var vindstilla visade det sig att den passiva provtagaren stämde bättre överens med impaktorerna. Den passivaprovtagarens massfördelning (förhållandet mellan små och stora partiklar) visade dessutom samma form som jämförelseinstrumentets. Vid den personburna provtagningen (med den passiva provtagaren) mättes damm från arbetsmiljön och inte sådant som kom från personen. Den nya modellen visade sig även här ge en förväntad massfördelning, medan den gamla modellen inte gjorde det. Den gamla modellen var mer fördelaktig för de största partiklarna och fick därför en skev fördelning. Den passiva provtagaren uppmätte dock mycket högre koncentrationer jämfört med cyklonen.Om hänsyn tas till att modellen måste ändras då det är vindstilla kan den passiva provtagaren användas för platsmätningar i gruvmiljön. För personburen provtagning mätte den passiva provtagaren dammet från arbetsmiljön och inte till exempel hud eller textilier. Den visade dock mycket högre koncentrationer av damm än jämförelseprovtagaren. Således kan den passiva provtagaren användas för platsmätningar i gruvmiljön, men den är ännu inte redo för personburen provtagning.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå university, 2018. s. 58
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1946
Nyckelord
dust particles, mineral, PM10, PM2.5, respirable fraction, UNC passive aerosol sampler, working environment
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Identifikatorer
urn:nbn:se:umu:diva-145704 (URN)978-91-7601-834-7 (ISBN)
Disputation
2018-04-13, Triple Helix, Samverkanshuset, Umeå, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2018-03-23 Skapad: 2018-03-14 Senast uppdaterad: 2024-07-02Bibliografiskt granskad

Open Access i DiVA

fulltext(822 kB)341 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 822 kBChecksumma SHA-512
03ef10102d13f744be318e90b7ac48d1339ba0a0a1448779d713be0f578670329b83241c855c31f72be396719e3e64aadaeefebfde5344f5c51c5be0816b8eaf
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Shirdel, MariamAndersson, Britt M.Bergdahl, IngvarSommar, Johan N.Liljelind, Ingrid E.

Sök vidare i DiVA

Av författaren/redaktören
Shirdel, MariamAndersson, Britt M.Bergdahl, IngvarSommar, Johan N.Liljelind, Ingrid E.
Av organisationen
Yrkes- och miljömedicinInstitutionen för tillämpad fysik och elektronik
I samma tidskrift
Annals of Work Exposures and Health
Arbetsmedicin och miljömedicinFysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 341 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 565 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-6th-edition.csl
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf