Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0001-7431-8335
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
2019 (Engelska)Ingår i: Sensors, E-ISSN 1424-8220, Vol. 19, nr 5, artikel-id 1241Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the system's validity of kinematic measures from inertial sensors for two such protocols on one person. Twenty healthy volunteers repeatedly performed two tasks, finger-to-nose and drinking, during two test sessions with two different raters. Five inertial sensors, on the forearms, upper arms and xiphoid process were used. Comparisons against an optical camera system evaluated the measurement validity. Cycle time, range of motion (ROM) in shoulder and elbow were calculated. Bland-Altman plots and linear mixed models including the generalizability (G) coefficient evaluated the reliability of the measures. Within-subject reliability was good to excellent in both tests (G = 0.80-0.97) and may serve as a baseline when assessing upper extremities in future patient groups. Overall reliability was acceptable to excellent (G = 0.77-0.94) for all parameters except elbow axial rotation in finger-to-nose task and both elbow axial rotation and flexion/extension in drinking task, mainly due to poor inter-rater reliability in these parameters. The low to good reliability for elbow ROM probably relates to high within-subject variability. The sensors provided good to excellent measures of cycle time and shoulder ROM in non-disabled individuals and thus have the potential to improve today's assessment of arm function.

Ort, förlag, år, upplaga, sidor
MDPI, 2019. Vol. 19, nr 5, artikel-id 1241
Nyckelord [en]
inter-rater reliability, inertial sensor, kinematics, upper limb, arm function
Nationell ämneskategori
Fysioterapi
Identifikatorer
URN: urn:nbn:se:umu:diva-158105DOI: 10.3390/s19051241ISI: 000462540400260PubMedID: 30870999Scopus ID: 2-s2.0-85062987798OAI: oai:DiVA.org:umu-158105DiVA, id: diva2:1304597
Tillgänglig från: 2019-04-12 Skapad: 2019-04-12 Senast uppdaterad: 2025-02-11Bibliografiskt granskad
Ingår i avhandling
1. Wearable systems and sensors for the assessment of motor control: Development and validation of methods for clinical assessment of idiopathic normal pressure hydrocephalus
Öppna denna publikation i ny flik eller fönster >>Wearable systems and sensors for the assessment of motor control: Development and validation of methods for clinical assessment of idiopathic normal pressure hydrocephalus
2021 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Bärbara system och sensorer för bedömning av motorisk kontroll : Utveckling och validering av metoder för klinisk bedömning av idiopatisk normaltryckshydrocefalus
Abstract [en]

Human gait and balance are controlled by automatic processes in the central nervous system, and in sensory and proprioceptive systems. If a disturbance occurs in any of these complex structures, it may lead to balance and gait problems. Equally important are the systems controlling the upper extremity functions where reach, grasp and manipulation skills may be affected. For the neurodegenerative disease idiopathic normal pressure hydrocephalus (iNPH), balance and gait disturbances are cardinal symptoms. Motor control of the upper extremities is also affected. In clinic today, physical impairment of persons with iNPH is commonly visually assessed using subjective, course tests with ordinal scales with the risk of missing minor changes. There is a lack of objective and quantitative ways to measure motor control in daily patient care. The aim of this thesis was to develop and validate tools for objective assessment of parameters that affect motor control in persons with iNPH.

Postural stability in stance and walking was assessed using gyroscopes in patients with iNPH, healthy elderly (HE) and patients with ventriculomegaly (VM). Compared to HE, patients with iNPH had reduced postural stability and relied less on vision. iNPH patients also had a lower trunk sway velocity than VM during walking. The gyroscopic system could quantitatively assess postural deficits in iNPH, making it a potentially useful tool for diagnosis and for clinical follow-up. The differences found during gait also suggests that walking, rather than quiet stance, should be further investigated for facilitating differential diagnosis compared to other patient groups with ventriculomegaly.

The gait in patients with iNPH is according to guidelines defined as slow, shuffling with a low foot-lift, and wide based. To objectively quantify the latter two features, a system (Striton) was developed in-house to assess the increased distance between the feet and the peak heel-height at the push-off phase of the gait cycle. It was validated in experimental setups, compared to gold standard motion capture systems (MCS), on healthy elderly (HE), through test-retest and day-to-day evaluations, and in four patients with iNPH. Striton demonstrated high correlations, in step-width and in heel-height, compared with the MCS. The mean step-width in the HE was 5.2 ± 0.9 cm (mean±Standard Deviation) and the heel-height 16.7±0.6 cm. Test-retest and day-to-day variations were small, ±0.5 cm in step-width and ±1.2 cm in heel-height, and differences in the parameters were seen between HE and iNPH both before and after surgery. Thus, Striton has the potential of quantitatively assessing gait parameters in HE and iNPH in a valuable manner.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå Universitet, 2021. s. 50
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 2130
Nyckelord
Gait, step-width, heel-heigt, balance, trunk sway, idiopathic normal pressure hydrocephalus, IMU, Inter-rater reliability, kinematics
Nationell ämneskategori
Medicinteknik Neurologi
Forskningsämne
medicinsk informatik
Identifikatorer
urn:nbn:se:umu:diva-182784 (URN)978-91-7855-523-9 (ISBN)978-91-7855-524-6 (ISBN)
Disputation
2021-06-04, Betula, Norrlands Universitetssjukhus, Umeå, 09:00 (Svenska)
Opponent
Handledare
Anmärkning

Disputationen sänds även via Zoom.

Tillgänglig från: 2021-05-12 Skapad: 2021-05-04 Senast uppdaterad: 2021-12-06Bibliografiskt granskad

Open Access i DiVA

fulltext(5517 kB)308 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 5517 kBChecksumma SHA-512
f2320f4d2919fb0a75742b087cacc5e091858df9bb450ea7ab2d23abf2905a99fc5356813c4325d27f5442e1f83ff5cc78f7b3f309987823d017ea63da262b7a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Öhberg, FredrikBäcklund, TomasSundström, NinaGrip, Helena

Sök vidare i DiVA

Av författaren/redaktören
Öhberg, FredrikBäcklund, TomasSundström, NinaGrip, Helena
Av organisationen
Radiofysik
I samma tidskrift
Sensors
Fysioterapi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 308 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 641 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf