Time-resolved continuous-filtering Vernier spectroscopy of H2O and OH radical in a flame
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.ORCID-id: 0000-0002-5065-7786
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik.ORCID-id: 0000-0002-6191-7926
2019 (Engelska)Ingår i: Optics Express, E-ISSN 1094-4087, Vol. 27, nr 21, s. 29521-29533Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We use broadband near-infrared continuous-filtering Vernier spectroscopy (CF-VS) for time-resolved detection of H2O and OH radical in a premixed CH4/air flat flame. The CF-VS spectrometer is based on a femtosecond Er:fiber laser, an external cavity that contains the flame, and a detection system comprising a rotating diffraction grating and photodetectors. Spectra of H2O and OH radical around 1570 nm are continuously recorded with 6.6 GHz spectral resolution, 4.0 x 10-7 cm-1 absorption sensitivity, and 25 ms time resolution, while the fuel-air equivalence ratio is periodically modulated with a square wave. The concentrations of the two analytes are retrieved with percent level precision by a fit of a Vernier model to each spectrum spanning 13 nm. The temporal profiles of both concentrations in each modulation cycle are repeatable and the steady-state concentration levels are in good agreement with predictions based on one-dimensional simulations of a static flat flame. The robust CF-VS spectrometer opens up for quantitative monitoring of multiple products of time-varying combustion processes with relatively simple data acquisition procedures.

Ort, förlag, år, upplaga, sidor
Optical Society of America, 2019. Vol. 27, nr 21, s. 29521-29533
Nyckelord [en]
Acoustooptic modulators, Cavity ring down spectroscopy, Coupling efficiency, Diffraction gratings, Fourier transform spectroscopy, Polarization maintaining fibers
Nationell ämneskategori
Atom- och molekylfysik och optik
Identifikatorer
URN: urn:nbn:se:umu:diva-164253DOI: 10.1364/OE.27.029521ISI: 000489954500006PubMedID: 31684212Scopus ID: 2-s2.0-85073615450OAI: oai:DiVA.org:umu-164253DiVA, id: diva2:1362138
Projekt
Bio4Energy
Forskningsfinansiär
Knut och Alice Wallenbergs Stiftelse, KAW 2015.0159Bio4EnergyTillgänglig från: 2019-10-18 Skapad: 2019-10-18 Senast uppdaterad: 2023-03-24Bibliografiskt granskad
Ingår i avhandling
1. Continuous-filtering Vernier spectroscopy
Öppna denna publikation i ny flik eller fönster >>Continuous-filtering Vernier spectroscopy
2022 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Kontinuerlig-filtrering Vernier spektroskopi
Abstract [en]

Continuous-filtering Vernier spectroscopy (CF-VS) is a laser-based detection technique that combines the broad spectral coverage of an optical frequency comb (OFC) with the enhanced interaction length provided by an optical cavity. The resonances of the cavity filter the OFC to a small group of comb modes that probe the transitions of the species present in the cavity. Controlling cavity resonances allows for a fast scanning of the selected comb modes across the full bandwidth of the comb. CF-VS delivers high detection sensitivity through its immunity to the frequency-to-amplitude-noise conversion. Previous works have shown the capability of CF-VS to perform sensitive and broadband measurements of multiple species in both the near-infrared (NIR) and the mid-infrared (MIR) regions. Those implementations required high-bandwidth stabilization via feedback to the comb sources, which resulted in bulky setups and complex operations. Moreover, they provided acquisition rates up to 20 Hz, limited by the mechanical design. Besides, the target species were measured under static conditions 一 CF-VS had not yet been employed to monitor any time-dependent processes.

The goal of the thesis was to address these issues. In the first project, we used CF-VS based on an Er:fiber comb to measure consecutive spectra of H2O and OH with 25 ms time resolution in a premixed flame whose fuel/air equivalence ratio was modulated with a square wave to simulate temporal perturbations. The concentrations of both species were retrieved with percent level precision, and their temporal profiles were repeatable in each modulation cycle. The steady-state concentrations were in good agreement with a static flame simulator. This work was the first demonstration of CF-VS and cavity-enhanced comb-based spectroscopy with ms time resolution.

In the second project, we implemented a new design of CF-VS that uses a compact Er:fiber comb and a custom-made moving aperture. This removes the requirement for high-bandwidth stabilization and allows acquisition rates up t0 100 Hz. To verify these capabilities, we measured CO2 and CH4 spectra in two spectral ranges. We developed a simple model to account for the influence of the high scanning speed above the adiabatic limit on the absorption signal.

The last project aimed to implement a robust and compact CF-VS spectrometer in the MIR region. For that, we improved an existing MIR source based on difference frequency generation (DFG) using a low-noise Yb:fiber pump, delay stabilization, and a novel polarization-maintaining silicon crystal fiber. The MIR comb uses a soliton generated in the fiber as the seed for DFG. We characterized the soliton using the pump laser. The wide tuning range of the soliton allows the idler to emit in the 2.7-4.2 μm range with high brightness.  The MIR comb has a simple delay stabilization and a fixed zero-offset frequency and was successfully implemented to measure high-resolution and precision spectra of CH3I using a comb-resolved Fourier transform spectrometer. Finally, we used the source to perform CF-VS by measuring CH4 spectra at around 3.3 μm. We showed that a single-shot spectrum could be successfully retrieved under the robust operation in the fingerprint regime. 

Ort, förlag, år, upplaga, sidor
Umeå: Umeå University, 2022. s. 60
Nyckelord
spectroscopy, spectrometer, laser, optical frequency comb, optical cavity, NIR, MIR, flame, robust, time resolution, spectrum
Nationell ämneskategori
Atom- och molekylfysik och optik
Forskningsämne
fysik
Identifikatorer
urn:nbn:se:umu:diva-192708 (URN)978-91-7855-743-1 (ISBN)978-91-7855-744-8 (ISBN)
Disputation
2022-03-18, Hörsal NAT.D.440, Naturvetarhuset, Umeå universitet, Umeå, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2022-02-25 Skapad: 2022-02-22 Senast uppdaterad: 2022-02-23Bibliografiskt granskad

Open Access i DiVA

fulltext(5179 kB)408 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 5179 kBChecksumma SHA-512
56280c926d51a5b66778c9a83690c3cd70c53ac6e83279400a7ed030d816f17eb5fc1a2e288513377a17ff58b478a767765d506d2b27bc9b312d65cdb7daffd2
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Lu, ChuangVieira, Francisco SennaSchmidt, Florian M.Foltynowicz, Aleksandra

Sök vidare i DiVA

Av författaren/redaktören
Lu, ChuangVieira, Francisco SennaSchmidt, Florian M.Foltynowicz, Aleksandra
Av organisationen
Institutionen för fysikInstitutionen för tillämpad fysik och elektronik
I samma tidskrift
Optics Express
Atom- och molekylfysik och optik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 408 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1401 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf