Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
PET/MRI attenuation correction in the pelvic region with a statistical decomposition method
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0002-3731-3612
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: European Journal of Nuclear Medicine and Molecular Imaging, ISSN 1619-7070, E-ISSN 1619-7089, Vol. 46, nr SUPPL 1, s. S289-S290Artikel i tidskrift, Meeting abstract (Övrigt vetenskapligt) Published
Abstract [en]

Aim/Introduction: Quantification in PET/MRI is of importance, and its accuracy is currently limited by the MR based attenuation correction estimate. A common method for attenuation correction of the pelvic region is based on a 2-echo Dixon MRI sequence for segmentation of fat and water and does not account for bone. In this work, we evaluate a new method for attenuation correction using an algorithm based on statistical decomposition of a T2 weighted MRI scan.

Materials and Methods: Substitute CT images (sCTs) were calculated from T2 weighted MRI scans with a statistical decomposition algorithm, originally developed for MRI-based radiotherapy dose-planning [1]. These sCTs benefits from having bone density information included, in addition to fat and water information. Prostate cancer patients from the PARAPLY study [2] were retrospectivelyselected, scanned with PET/MRI 11C-Acatate and CT the same day. The stand-alone CT images were transformed to the same geometry as the PET and MR images, using a non-rigid registration. CT images, generated sCT images, and the Dixonbased attenuation maps (MRAC), all in the same geometry, were together with the PET raw data used to reconstruct attenuation-corrected PET images using the PETrecon toolbox [GE Healthcare]. The two MR-based attenuation corrections were compared to the CT-based attenuation correction with root mean squared error (RMSE). Lesion analysis will also be reported. PET/MRI images were acquired on a Signa PET/MRI (GE Healthcare), and the CT images on a Brilliance Big Bore (Phillips Healthcare). The study will include 12 patients and a subset of 6 patients has been analyzed so far and is presented here.

Results: Soft tissue in-between pelvic bone structures were overestimated with 13% in MRAC-PET, and the error was reduced to 5% with sCT attenuation corrected PET (sCT-PET). For the whole patient volume, an average underestimation of 6% was found in the MRAC-PET, compared to 1% for sCTPET. RMSE within the body was reduced with a factor 2.5 with sCT-PET (RMSE=3.6%), compared to MRAC-PET (RMSE=8.8%).

Conclusion: Applying sCT from statistical decomposition as a base for calculation of attenuation maps reduces quantification errors in PET-images of the pelvic region compared to the common Dixon based method.

Ort, förlag, år, upplaga, sidor
Springer, 2019. Vol. 46, nr SUPPL 1, s. S289-S290
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-165323ISI: 000492444402146OAI: oai:DiVA.org:umu-165323DiVA, id: diva2:1374838
Konferens
32nd Annual Congress of the European-Association-of-Nuclear-Medicine (EANM), Barcelona, SPAIN, OCT 12-16, 2019
Tillgänglig från: 2019-12-03 Skapad: 2019-12-03 Senast uppdaterad: 2024-07-02Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

URL

Person

Wallstén, ElinAxelsson, JanJonsson, JoakimThellenberg-Karlsson, CamillaNyholm, TufveLarsson, Anne

Sök vidare i DiVA

Av författaren/redaktören
Wallstén, ElinAxelsson, JanJonsson, JoakimThellenberg-Karlsson, CamillaNyholm, TufveLarsson, Anne
Av organisationen
RadiofysikOnkologi
I samma tidskrift
European Journal of Nuclear Medicine and Molecular Imaging
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 381 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf