Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect of sample preparation techniques upon single cell chemical imaging: A practical comparison between synchrotron radiation based X-ray fluorescence (SR-XRF) and Nanoscopic Secondary Ion Mass Spectrometry (nano-SIMS)
Visa övriga samt affilieringar
2020 (Engelska)Ingår i: Analytica Chimica Acta, ISSN 0003-2670, E-ISSN 1873-4324, Vol. 1106, s. 22-32Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Analytical capabilities of Nanoscopic Secondary Ion Mass Spectrometry (nano-SIMS) and Synchrotron Radiation based X-ray Fluorescence (SR nano-XRF) techniques were compared for nanochemical imaging of polymorphonuclear human neutrophils (PMNs). PMNs were high pressure frozen (HPF), cryosubstituted, embedded in Spurr's resin and cut in thin sections (500 nm and 2 mu m for both techniques resp.) Nano-SIMS enabled nanoscale mapping of isotopes of C, N, O, P and S, while SR based nano-XRF enabled trace level imaging of metals like Ca, Mn, Fe, Ni, Cu and Zn at a resolution of approx. 50 nm. The obtained elemental distributions were compared with those of whole, cryofrozen PMNs measured at the newly developed ID16A nano-imaging beamline at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Similarities were observed for elements more tightly bound to the cell structure such as phosphorus and sulphur, while differences for mobile ions such as chlorine and potassium were more pronounced. Due to the observed elemental redistribution of mobile ions such as potassium and chlorine, elemental analysis of high pressure frozen (HPF), cryo-substituted and imbedded cells should be interpreted critically. Although decreasing analytical sensitivity occurs due to the presence of ice, analysis of cryofrozen cells - close to their native state - remains the golden standard. In general, we found nanoscale secondary ion mass spectrometry (nano-SIMS) and synchrotron radiation based nanoscopic X-ray fluorescence (SR nano-XRF) to be two supplementary alternatives for nanochemical imaging of single cells at the nanoscale. 

Ort, förlag, år, upplaga, sidor
Elsevier, 2020. Vol. 1106, s. 22-32
Nyckelord [en]
Synchrotron radiation, X-ray fluorescence, XRF, Nano-SIMS, Cell imaging, Sample preparation
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:umu:diva-169366DOI: 10.1016/j.aca.2020.01.054ISI: 000519110500002PubMedID: 32145852Scopus ID: 2-s2.0-85079038777OAI: oai:DiVA.org:umu-169366DiVA, id: diva2:1422342
Tillgänglig från: 2020-04-07 Skapad: 2020-04-07 Senast uppdaterad: 2024-07-02Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Sandblad, LindaUrban, Constantin F.

Sök vidare i DiVA

Av författaren/redaktören
Sandblad, LindaBohic, SylvainCloetens, PeterUrban, Constantin F.
Av organisationen
Institutionen för molekylärbiologi (Medicinska fakulteten)Institutionen för klinisk mikrobiologi
I samma tidskrift
Analytica Chimica Acta
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 424 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf